pgurazada1
commited on
Commit
•
c170624
1
Parent(s):
743eba1
Upload 3 files
Browse files
dev.txt
ADDED
@@ -0,0 +1,62 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
+
inefficient,Plugged / choked
|
2 |
+
hole,Structural deficiency
|
3 |
+
stopped,Spurious stop
|
4 |
+
failing to open fully,Fail to open
|
5 |
+
stopped communicatiing,Spurious stop
|
6 |
+
gone,Minor in-service problems
|
7 |
+
has high earth resistance,Electrical
|
8 |
+
unserviceable su,Breakdown
|
9 |
+
leak excessivly,Leaking
|
10 |
+
unable to get running,Failure to start on demand
|
11 |
+
flickering anytime,Erratic output
|
12 |
+
needs descale,Minor in-service problems
|
13 |
+
spilling,Leaking
|
14 |
+
not square,Minor in-service problems
|
15 |
+
rocking voilently,Vibration
|
16 |
+
burnt off,Overheating
|
17 |
+
twisted,Fail to function
|
18 |
+
keeps tripping on start up,Electrical
|
19 |
+
unsecure,Minor in-service problems
|
20 |
+
not pumping away,Plugged / choked
|
21 |
+
siezedjammed,Breakdown
|
22 |
+
no output,Plugged / choked
|
23 |
+
faulted,Electrical
|
24 |
+
burn,Overheating
|
25 |
+
smoking hot,Overheating
|
26 |
+
issue,Other
|
27 |
+
erroded,Structural deficiency
|
28 |
+
leak out,Leaking
|
29 |
+
detaching,Minor in-service problems
|
30 |
+
passing slurry,Leaking
|
31 |
+
leak u,Leaking
|
32 |
+
low pressure,Plugged / choked
|
33 |
+
not reading,Abnormal instrument reading
|
34 |
+
wornblocked,Structural deficiency
|
35 |
+
require replacing,Breakdown
|
36 |
+
not starting in sequence,Failure to start on demand
|
37 |
+
requires descale,Minor in-service problems
|
38 |
+
feedback,Electrical
|
39 |
+
misaligned,Minor in-service problems
|
40 |
+
unable to increase,Low output
|
41 |
+
defect,Structural deficiency
|
42 |
+
constantly tripping,Electrical
|
43 |
+
excesively worn,Structural deficiency
|
44 |
+
need change,Breakdown
|
45 |
+
not readingfalse,Abnormal instrument reading
|
46 |
+
snaped off,Structural deficiency
|
47 |
+
requires de scale,Minor in-service problems
|
48 |
+
not holding,Leaking
|
49 |
+
badly worn,Structural deficiency
|
50 |
+
deformed,Structural deficiency
|
51 |
+
tripping instantly,Electrical
|
52 |
+
not maintaining pressure,Plugged / choked
|
53 |
+
needs tuning,Minor in-service problems
|
54 |
+
moving a lot,Vibration
|
55 |
+
stops during operation,Spurious stop
|
56 |
+
missing hold down,Minor in-service problems
|
57 |
+
will not fully close,Fail to function
|
58 |
+
will not reset,Failure to start on demand
|
59 |
+
flooding,Leaking
|
60 |
+
need marking up,Minor in-service problems
|
61 |
+
not in sequence,Electrical
|
62 |
+
stiff to turn,Fail to function
|
test.txt
ADDED
@@ -0,0 +1,62 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
+
ejected,Minor in-service problems
|
2 |
+
sticking shu,Fail to function
|
3 |
+
not turning,Plugged / choked
|
4 |
+
has failed,Breakdown
|
5 |
+
needs fitting,Minor in-service problems
|
6 |
+
runs for a while and trip,Electrical
|
7 |
+
very stiff to operate,Fail to function
|
8 |
+
requires rebuild,Minor in-service problems
|
9 |
+
has no equipment earth,Electrical
|
10 |
+
require tighteninginspecti,Minor in-service problems
|
11 |
+
does not work,Breakdown
|
12 |
+
runs continuously,Failure to stop on demand
|
13 |
+
severe corrosion,Structural deficiency
|
14 |
+
contamination,Contamination
|
15 |
+
doesnt trip,Electrical
|
16 |
+
ripped,Structural deficiency
|
17 |
+
unserviceable not in,Breakdown
|
18 |
+
cant be adjusted,Fail to function
|
19 |
+
worn,Structural deficiency
|
20 |
+
misalignment,Minor in-service problems
|
21 |
+
switched o,Spurious stop
|
22 |
+
to be torqued,Minor in-service problems
|
23 |
+
sped up,High output
|
24 |
+
unable to pump,Low output
|
25 |
+
spillage,Leaking
|
26 |
+
spraying out slurry,Leaking
|
27 |
+
jammed open,Plugged / choked
|
28 |
+
no pump,Plugged / choked
|
29 |
+
not truning,Plugged / choked
|
30 |
+
unable to tighten,Minor in-service problems
|
31 |
+
burnt,Overheating
|
32 |
+
hot joint,Overheating
|
33 |
+
burst,Breakdown
|
34 |
+
pumping fault,Low output
|
35 |
+
not controlling,Minor in-service problems
|
36 |
+
surging cutting in and out,Electrical
|
37 |
+
failed electrical,Electrical
|
38 |
+
loose tighten,Minor in-service problems
|
39 |
+
high earth reading,Abnormal instrument reading
|
40 |
+
cavitating,Erratic output
|
41 |
+
requires repack,Minor in-service problems
|
42 |
+
needs support,Minor in-service problems
|
43 |
+
needs maintenance,Minor in-service problems
|
44 |
+
not spinning,Minor in-service problems
|
45 |
+
dont activate,Failure to start on demand
|
46 |
+
unserviceable b feluwa,Breakdown
|
47 |
+
no power,Electrical
|
48 |
+
requires cleaning,Minor in-service problems
|
49 |
+
doesnt work,Breakdown
|
50 |
+
vibrationlubealignment,Vibration
|
51 |
+
blockage,Plugged / choked
|
52 |
+
ongoing issue,Other
|
53 |
+
poorly supported,Minor in-service problems
|
54 |
+
rocking around,Vibration
|
55 |
+
siezeddescale,Breakdown
|
56 |
+
dropped,Minor in-service problems
|
57 |
+
spraying,Leaking
|
58 |
+
not covered,Minor in-service problems
|
59 |
+
hot jointfurn,Overheating
|
60 |
+
running dry,Other
|
61 |
+
smoking up,Overheating
|
62 |
+
jammed,Plugged / choked
|
train.txt
ADDED
@@ -0,0 +1,502 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
+
falure,Breakdown
|
2 |
+
unserviceable dpr 1,Breakdown
|
3 |
+
bogged,Plugged / choked
|
4 |
+
spaying slurry,Leaking
|
5 |
+
fell of,Minor in-service problems
|
6 |
+
no pressure output,Plugged / choked
|
7 |
+
damageblockage,Structural deficiency
|
8 |
+
squeeling,Noise
|
9 |
+
requires repacking,Minor in-service problems
|
10 |
+
no starting issue,Failure to start on demand
|
11 |
+
shaking,Vibration
|
12 |
+
blow,Minor in-service problems
|
13 |
+
need a descale,Minor in-service problems
|
14 |
+
over heating,Overheating
|
15 |
+
vibrationcheck,Vibration
|
16 |
+
vibration issue,Vibration
|
17 |
+
not open,Minor in-service problems
|
18 |
+
sticking,Fail to function
|
19 |
+
seized shut,Breakdown
|
20 |
+
blocked,Plugged / choked
|
21 |
+
not working,Breakdown
|
22 |
+
not energising,Low output
|
23 |
+
power issue,Electrical
|
24 |
+
needs repairing,Structural deficiency
|
25 |
+
not performing,Breakdown
|
26 |
+
wont run and,Failure to start on demand
|
27 |
+
boil out,Overheating
|
28 |
+
not supplying,Plugged / choked
|
29 |
+
spilled,Leaking
|
30 |
+
stuck in,Fail to function
|
31 |
+
leak exponentially,Leaking
|
32 |
+
not keeping up,Low output
|
33 |
+
pumping issue,Low output
|
34 |
+
leak slurry,Leaking
|
35 |
+
us,Breakdown
|
36 |
+
requires attention,Minor in-service problems
|
37 |
+
does not stop,Failure to stop on demand
|
38 |
+
noisy sce,Noise
|
39 |
+
twisting,Fail to function
|
40 |
+
needs to be extended,Minor in-service problems
|
41 |
+
lost its packing,Leaking
|
42 |
+
rusted through,Structural deficiency
|
43 |
+
needs to be held down,Minor in-service problems
|
44 |
+
flow issue,Plugged / choked
|
45 |
+
degraded,Structural deficiency
|
46 |
+
wont pump floc,Breakdown
|
47 |
+
leakspray,Leaking
|
48 |
+
wont run in,Failure to start on demand
|
49 |
+
needs repacked,Minor in-service problems
|
50 |
+
passing excessively,Leaking
|
51 |
+
blocking,Plugged / choked
|
52 |
+
not engaging,Failure to start on demand
|
53 |
+
shredded,Structural deficiency
|
54 |
+
noise,Noise
|
55 |
+
blown out,Minor in-service problems
|
56 |
+
needs replacing,Breakdown
|
57 |
+
not running,Breakdown
|
58 |
+
leak when shut,Leaking
|
59 |
+
fall off,Minor in-service problems
|
60 |
+
not being pumped away,Plugged / choked
|
61 |
+
scaled up,Minor in-service problems
|
62 |
+
fallen off,Minor in-service problems
|
63 |
+
broke away,Breakdown
|
64 |
+
cannot run in,Failure to start on demand
|
65 |
+
not pumping enough,Plugged / choked
|
66 |
+
not stopping,Failure to stop on demand
|
67 |
+
unable to shu,Failure to stop on demand
|
68 |
+
failed internaly,Breakdown
|
69 |
+
not there,Minor in-service problems
|
70 |
+
inefficiant,Plugged / choked
|
71 |
+
no reading,Abnormal instrument reading
|
72 |
+
will not start in,Failure to start on demand
|
73 |
+
been running hot,Overheating
|
74 |
+
fallen out,Minor in-service problems
|
75 |
+
leak on,Leaking
|
76 |
+
to be removed,Breakdown
|
77 |
+
unsupported,Minor in-service problems
|
78 |
+
giving false reading,Abnormal instrument reading
|
79 |
+
leak in two place,Leaking
|
80 |
+
not reaching flow,Plugged / choked
|
81 |
+
wont turn,Failure to start on demand
|
82 |
+
not able to open,Minor in-service problems
|
83 |
+
need straighting,Minor in-service problems
|
84 |
+
hot liquid,Overheating
|
85 |
+
fell apart,Minor in-service problems
|
86 |
+
fail again,Breakdown
|
87 |
+
needs to be replaced,Breakdown
|
88 |
+
underperforming,Low output
|
89 |
+
corroded close out,Structural deficiency
|
90 |
+
not kicking in,Failure to start on demand
|
91 |
+
needs to be descaled,Minor in-service problems
|
92 |
+
over flowed,Leaking
|
93 |
+
non operational,Breakdown
|
94 |
+
running fault,Other
|
95 |
+
unable to run,Failure to start on demand
|
96 |
+
come adrift,Minor in-service problems
|
97 |
+
stiff,Fail to function
|
98 |
+
not high enough,Low output
|
99 |
+
broken off,Breakdown
|
100 |
+
snapped,Structural deficiency
|
101 |
+
shorted out,Electrical
|
102 |
+
running when sump empty,Other
|
103 |
+
faul,Electrical
|
104 |
+
has a hole on,Structural deficiency
|
105 |
+
will not trip,Electrical
|
106 |
+
failing to start,Failure to start on demand
|
107 |
+
needs adjusting,Minor in-service problems
|
108 |
+
sheared,Structural deficiency
|
109 |
+
failed,Breakdown
|
110 |
+
no guarding,Minor in-service problems
|
111 |
+
unresponsive,Failure to start on demand
|
112 |
+
no sightglass,Minor in-service problems
|
113 |
+
not connected,Minor in-service problems
|
114 |
+
unserviceable and line,Breakdown
|
115 |
+
keeps triping,Electrical
|
116 |
+
coming out,Minor in-service problems
|
117 |
+
requires handle,Minor in-service problems
|
118 |
+
low flow,Plugged / choked
|
119 |
+
split,Structural deficiency
|
120 |
+
fail to start,Failure to start on demand
|
121 |
+
wont reset,Failure to start on demand
|
122 |
+
hard to close,Fail to close
|
123 |
+
hole in suction,Structural deficiency
|
124 |
+
worn through,Structural deficiency
|
125 |
+
passingleaking,Leaking
|
126 |
+
not opening,Minor in-service problems
|
127 |
+
jammedseized,Plugged / choked
|
128 |
+
damage,Structural deficiency
|
129 |
+
passing on,Leaking
|
130 |
+
weak,Other
|
131 |
+
viberating,Vibration
|
132 |
+
static earth resistance,Electrical
|
133 |
+
needs to be rebuilt,Minor in-service problems
|
134 |
+
needs supporting,Minor in-service problems
|
135 |
+
wont work,Failure to start on demand
|
136 |
+
wornbelt,Structural deficiency
|
137 |
+
not attached corroded,Minor in-service problems
|
138 |
+
keeps tripping,Electrical
|
139 |
+
weeping,Leaking
|
140 |
+
badly rusted,Structural deficiency
|
141 |
+
bad vibration,Vibration
|
142 |
+
fire,Overheating
|
143 |
+
faulting,Electrical
|
144 |
+
contaminating condensate,Contamination
|
145 |
+
too fast,High output
|
146 |
+
low viscosity,Contamination
|
147 |
+
not closing,Minor in-service problems
|
148 |
+
require adjusting,Minor in-service problems
|
149 |
+
sound,Noise
|
150 |
+
bent,Minor in-service problems
|
151 |
+
corrosion on,Structural deficiency
|
152 |
+
doesnt operate,Breakdown
|
153 |
+
seized open,Breakdown
|
154 |
+
excessive stopstart,Erratic output
|
155 |
+
needs replaceing,Breakdown
|
156 |
+
hot thermography,Overheating
|
157 |
+
erratic,Erratic output
|
158 |
+
false high level,Abnormal instrument reading
|
159 |
+
will not shut,Fail to function
|
160 |
+
lagging,Low output
|
161 |
+
blew off,Minor in-service problems
|
162 |
+
no fill,Minor in-service problems
|
163 |
+
needs packing,Minor in-service problems
|
164 |
+
wont pump,Breakdown
|
165 |
+
badly corrod,Structural deficiency
|
166 |
+
surging,Electrical
|
167 |
+
false reading,Abnormal instrument reading
|
168 |
+
not pumping enough to get,Plugged / choked
|
169 |
+
not draining,Plugged / choked
|
170 |
+
not wo,Breakdown
|
171 |
+
not charging,Electrical
|
172 |
+
locked,Failure to rotate
|
173 |
+
not moving,Plugged / choked
|
174 |
+
milky,Contamination
|
175 |
+
require tightening,Minor in-service problems
|
176 |
+
siezed,Breakdown
|
177 |
+
no pressure,Plugged / choked
|
178 |
+
disconnected,Breakdown
|
179 |
+
coming adrift,Minor in-service problems
|
180 |
+
ruptured,Structural deficiency
|
181 |
+
not pumpung,Plugged / choked
|
182 |
+
leakhose,Leaking
|
183 |
+
cracked,Structural deficiency
|
184 |
+
broken loose,Breakdown
|
185 |
+
failing,Breakdown
|
186 |
+
looseworn,Minor in-service problems
|
187 |
+
alarming eratically,Abnormal instrument reading
|
188 |
+
are not operational,Breakdown
|
189 |
+
no static,Abnormal instrument reading
|
190 |
+
siezed shut,Breakdown
|
191 |
+
running too slow,Low output
|
192 |
+
rusty,Structural deficiency
|
193 |
+
needs modifying,Minor in-service problems
|
194 |
+
died,Breakdown
|
195 |
+
smoking,Overheating
|
196 |
+
pulling very high,High output
|
197 |
+
blowin,Minor in-service problems
|
198 |
+
not stopping at,Failure to stop on demand
|
199 |
+
not operational,Breakdown
|
200 |
+
seizedbogged,Breakdown
|
201 |
+
usversicol,Breakdown
|
202 |
+
static,Electrical
|
203 |
+
does not trip,Electrical
|
204 |
+
needs alignment,Minor in-service problems
|
205 |
+
contaimination,Contamination
|
206 |
+
burst again,Breakdown
|
207 |
+
smoke,Overheating
|
208 |
+
losing,Minor in-service problems
|
209 |
+
no belt,Minor in-service problems
|
210 |
+
needs tightened,Minor in-service problems
|
211 |
+
not turning restriction,Plugged / choked
|
212 |
+
no signal,Abnormal instrument reading
|
213 |
+
emulsified,Contamination
|
214 |
+
alarming vibration,Vibration
|
215 |
+
needs patched up,Minor in-service problems
|
216 |
+
blew off top of,Minor in-service problems
|
217 |
+
badly corroded in,Structural deficiency
|
218 |
+
perished,Breakdown
|
219 |
+
need calibration,Abnormal instrument reading
|
220 |
+
jammed in place,Plugged / choked
|
221 |
+
collapsed,Breakdown
|
222 |
+
requires slotting,Minor in-service problems
|
223 |
+
fault finding,Electrical
|
224 |
+
reading inaccurate,Abnormal instrument reading
|
225 |
+
sucked in,Other
|
226 |
+
come loose,Minor in-service problems
|
227 |
+
no phase,Electrical
|
228 |
+
bore tripping,Electrical
|
229 |
+
spill to ground,Electrical
|
230 |
+
reading high,Abnormal instrument reading
|
231 |
+
rusted away,Structural deficiency
|
232 |
+
needs a repack,Minor in-service problems
|
233 |
+
fried,Breakdown
|
234 |
+
no speed control,Abnormal instrument reading
|
235 |
+
seized breakdown,Breakdown
|
236 |
+
needs replacement,Breakdown
|
237 |
+
not workin,Breakdown
|
238 |
+
require investigating,Minor in-service problems
|
239 |
+
passing when closed,Leaking
|
240 |
+
not operating,Breakdown
|
241 |
+
crack,Structural deficiency
|
242 |
+
stopped pumping,Spurious stop
|
243 |
+
not pumping issue,Plugged / choked
|
244 |
+
vibration,Vibration
|
245 |
+
no flow,Plugged / choked
|
246 |
+
restricted,Low output
|
247 |
+
high vibration,Vibration
|
248 |
+
unserviceable no contol,Breakdown
|
249 |
+
slippery,Minor in-service problems
|
250 |
+
no seal,Minor in-service problems
|
251 |
+
leak underflow,Leaking
|
252 |
+
blockedseized,Plugged / choked
|
253 |
+
broken near,Breakdown
|
254 |
+
faulty earth,Electrical
|
255 |
+
not maintaining,Plugged / choked
|
256 |
+
wont rotate,Failure to start on demand
|
257 |
+
not efficient,Low output
|
258 |
+
will not start,Failure to start on demand
|
259 |
+
contamination trip,Contamination
|
260 |
+
not working on,Breakdown
|
261 |
+
blown out at,Minor in-service problems
|
262 |
+
trips out,Electrical
|
263 |
+
struggling,Low output
|
264 |
+
slow,Low output
|
265 |
+
keeps on tripping,Electrical
|
266 |
+
reading stuck,Abnormal instrument reading
|
267 |
+
not pumping,Plugged / choked
|
268 |
+
torn,Structural deficiency
|
269 |
+
cutting in and out,Erratic output
|
270 |
+
leakhole,Leaking
|
271 |
+
come free of,Minor in-service problems
|
272 |
+
contaminated,Contamination
|
273 |
+
not pumpingeast,Plugged / choked
|
274 |
+
no oil movement,Plugged / choked
|
275 |
+
cold,Other
|
276 |
+
problem,Other
|
277 |
+
keeps tripping at start,Electrical
|
278 |
+
severely corroded,Structural deficiency
|
279 |
+
needs repack,Minor in-service problems
|
280 |
+
not secure,Minor in-service problems
|
281 |
+
missing on,Minor in-service problems
|
282 |
+
require changing,Minor in-service problems
|
283 |
+
have smoked up,Overheating
|
284 |
+
rusted of,Structural deficiency
|
285 |
+
relieving too early,Leaking
|
286 |
+
missing blank,Minor in-service problems
|
287 |
+
will not restart,Failure to start on demand
|
288 |
+
needs repacking,Minor in-service problems
|
289 |
+
high amp,Abnormal instrument reading
|
290 |
+
weaping,Leaking
|
291 |
+
burnt out,Overheating
|
292 |
+
blowen,Minor in-service problems
|
293 |
+
adrift,Minor in-service problems
|
294 |
+
seizes at time,Breakdown
|
295 |
+
may burst,Structural deficiency
|
296 |
+
sparaying,Leaking
|
297 |
+
tripping straight away,Electrical
|
298 |
+
has a split in,Structural deficiency
|
299 |
+
corrodedstripped,Structural deficiency
|
300 |
+
buggered,Breakdown
|
301 |
+
seized,Breakdown
|
302 |
+
pot in backward,Minor in-service problems
|
303 |
+
fault,Electrical
|
304 |
+
will not pump,Breakdown
|
305 |
+
tripping in,Electrical
|
306 |
+
requires replacing,Minor in-service problems
|
307 |
+
continually tripping,Electrical
|
308 |
+
no run indication,Abnormal instrument reading
|
309 |
+
running hot,Overheating
|
310 |
+
poor,Fail to function
|
311 |
+
keeps tripping out,Electrical
|
312 |
+
playing up,Erratic output
|
313 |
+
not providing pressure,Plugged / choked
|
314 |
+
not starting,Failure to start on demand
|
315 |
+
sheared off,Structural deficiency
|
316 |
+
not puming,Plugged / choked
|
317 |
+
corroding,Structural deficiency
|
318 |
+
spraying out of,Leaking
|
319 |
+
badly corroded,Structural deficiency
|
320 |
+
requires clean,Minor in-service problems
|
321 |
+
holedinspect,Structural deficiency
|
322 |
+
no earth,Electrical
|
323 |
+
missingloose,Minor in-service problems
|
324 |
+
siezing on,Breakdown
|
325 |
+
keeps kicking in,Failure to stop on demand
|
326 |
+
not efficiant,Low output
|
327 |
+
sheered,Structural deficiency
|
328 |
+
incorrect orientation,Minor in-service problems
|
329 |
+
worn out,Structural deficiency
|
330 |
+
signal error,Abnormal instrument reading
|
331 |
+
earth fault,Electrical
|
332 |
+
unserviceable pump,Breakdown
|
333 |
+
not attached,Minor in-service problems
|
334 |
+
leaked out,Leaking
|
335 |
+
shorting out,Electrical
|
336 |
+
tripping on overload,Electrical
|
337 |
+
broken,Breakdown
|
338 |
+
heavy corrosion,Structural deficiency
|
339 |
+
unable to reach,Low output
|
340 |
+
wont open,Fail to function
|
341 |
+
lealing,Leaking
|
342 |
+
needs another row,Minor in-service problems
|
343 |
+
down to earth,Electrical
|
344 |
+
very corroded,Structural deficiency
|
345 |
+
will not start after flushing,Failure to start on demand
|
346 |
+
slurry spraying out,Leaking
|
347 |
+
badly corr,Structural deficiency
|
348 |
+
covered,Minor in-service problems
|
349 |
+
requires a descale,Minor in-service problems
|
350 |
+
starting to crack,Structural deficiency
|
351 |
+
crack in transition,Structural deficiency
|
352 |
+
constantly losing,Leaking
|
353 |
+
continually trips out,Electrical
|
354 |
+
dirty,Minor in-service problems
|
355 |
+
worn again,Structural deficiency
|
356 |
+
broke,Breakdown
|
357 |
+
needs to be flushed,Minor in-service problems
|
358 |
+
rusted off,Structural deficiency
|
359 |
+
stopped working,Spurious stop
|
360 |
+
stuck,Fail to function
|
361 |
+
appears loose,Minor in-service problems
|
362 |
+
very high vibration,Vibration
|
363 |
+
cannot start,Failure to start on demand
|
364 |
+
not secured,Minor in-service problems
|
365 |
+
holed,Structural deficiency
|
366 |
+
jammed closed,Plugged / choked
|
367 |
+
tripping cause,Electrical
|
368 |
+
coroded,Structural deficiency
|
369 |
+
needs to be dismantled,Minor in-service problems
|
370 |
+
missing off,Minor in-service problems
|
371 |
+
knocking,Noise
|
372 |
+
slipping,Minor in-service problems
|
373 |
+
tripping on,Electrical
|
374 |
+
caught in suction,Minor in-service problems
|
375 |
+
defect notice,Structural deficiency
|
376 |
+
will not stay running,Spurious stop
|
377 |
+
come off,Minor in-service problems
|
378 |
+
tripped out,Electrical
|
379 |
+
not accurate,Abnormal instrument reading
|
380 |
+
loose,Minor in-service problems
|
381 |
+
has crack,Structural deficiency
|
382 |
+
congested,Plugged / choked
|
383 |
+
shows offline while running in field,Abnormal instrument reading
|
384 |
+
showing signs of failure,Other
|
385 |
+
passing,Leaking
|
386 |
+
broken electrical,Breakdown
|
387 |
+
spraying out,Leaking
|
388 |
+
needs freeing up,Plugged / choked
|
389 |
+
wont start,Failure to start on demand
|
390 |
+
high earth resistance,Abnormal instrument reading
|
391 |
+
pumping at high out put,High output
|
392 |
+
pinholed,Minor in-service problems
|
393 |
+
poor flow,Low output
|
394 |
+
slipped off,Minor in-service problems
|
395 |
+
faulty,Electrical
|
396 |
+
needs scope,Minor in-service problems
|
397 |
+
colapsed,Breakdown
|
398 |
+
will not run,Breakdown
|
399 |
+
exposed,Minor in-service problems
|
400 |
+
losing signal,Electrical
|
401 |
+
misaligning,Minor in-service problems
|
402 |
+
out of position,Minor in-service problems
|
403 |
+
need replacing,Breakdown
|
404 |
+
not running in,Fail to function
|
405 |
+
has split,Structural deficiency
|
406 |
+
snapped off,Structural deficiency
|
407 |
+
noisyvibrating,Noise
|
408 |
+
filled,Leaking
|
409 |
+
fail,Breakdown
|
410 |
+
fails to open in sequence,Fail to open
|
411 |
+
looseness,Minor in-service problems
|
412 |
+
too high,High output
|
413 |
+
blowing,Minor in-service problems
|
414 |
+
running when empty,Other
|
415 |
+
hot,Overheating
|
416 |
+
fluctuates at high rate,Erratic output
|
417 |
+
not reading right,Abnormal instrument reading
|
418 |
+
sitting on hot,Overheating
|
419 |
+
not able to maintain level,Plugged / choked
|
420 |
+
dislodged,Minor in-service problems
|
421 |
+
turning in reverse,Fail to function
|
422 |
+
no out put,Plugged / choked
|
423 |
+
leaky,Leaking
|
424 |
+
tripping out on run up,Electrical
|
425 |
+
need replaceing,Breakdown
|
426 |
+
not pump,Plugged / choked
|
427 |
+
will not run in,Breakdown
|
428 |
+
needs rebuild,Breakdown
|
429 |
+
leakingreplace,Leaking
|
430 |
+
stopped abruptly,Spurious stop
|
431 |
+
brittle,Structural deficiency
|
432 |
+
needs securing,Minor in-service problems
|
433 |
+
dented,Structural deficiency
|
434 |
+
vibrationlaser,Vibration
|
435 |
+
inconsistant flow,Plugged / choked
|
436 |
+
needs re build,Breakdown
|
437 |
+
unserviceable please replace,Breakdown
|
438 |
+
not connectedblanked,Minor in-service problems
|
439 |
+
earthing,Electrical
|
440 |
+
no indication,Minor in-service problems
|
441 |
+
stripped,Structural deficiency
|
442 |
+
needs inspecting,Minor in-service problems
|
443 |
+
snaped,Structural deficiency
|
444 |
+
didnt trip,Electrical
|
445 |
+
blow out,Minor in-service problems
|
446 |
+
unserviceable leak sulphur,Breakdown
|
447 |
+
tripping issue,Electrical
|
448 |
+
unable to reset,Failure to stop on demand
|
449 |
+
need modifying,Minor in-service problems
|
450 |
+
tripping out,Electrical
|
451 |
+
requires topupstop,Minor in-service problems
|
452 |
+
dragged,Minor in-service problems
|
453 |
+
not performingpumping,Breakdown
|
454 |
+
getting jammed,Plugged / choked
|
455 |
+
failed restest,Failure to start on demand
|
456 |
+
starting issue,Failure to start on demand
|
457 |
+
wrong range,Abnormal instrument reading
|
458 |
+
may be failing,Fail to function
|
459 |
+
stretched,Minor in-service problems
|
460 |
+
does dont pump at,Plugged / choked
|
461 |
+
stuck in open position,Fail to function
|
462 |
+
seize,Breakdown
|
463 |
+
hole in,Structural deficiency
|
464 |
+
snappedplugged,Structural deficiency
|
465 |
+
consumeing,Leaking
|
466 |
+
keeps vibrating shut,Vibration
|
467 |
+
not able to pump,Plugged / choked
|
468 |
+
needs a descale,Minor in-service problems
|
469 |
+
passing u,Leaking
|
470 |
+
out of adjustment,Minor in-service problems
|
471 |
+
failure,Breakdown
|
472 |
+
needs reset,Electrical
|
473 |
+
rupture,Structural deficiency
|
474 |
+
vibrating,Vibration
|
475 |
+
rubbing,Vibration
|
476 |
+
leakingneed,Leaking
|
477 |
+
playingup,Erratic output
|
478 |
+
broken into,Breakdown
|
479 |
+
doesnt pump to,Plugged / choked
|
480 |
+
corrosion,Structural deficiency
|
481 |
+
squealing,Noise
|
482 |
+
noyt pumping,Breakdown
|
483 |
+
fault tripping,Electrical
|
484 |
+
needs to be repacked,Minor in-service problems
|
485 |
+
will not turn,Fail to function
|
486 |
+
grinding,Noise
|
487 |
+
rusted,Structural deficiency
|
488 |
+
trips on overload,Electrical
|
489 |
+
stopping,Spurious stop
|
490 |
+
split in two place,Structural deficiency
|
491 |
+
hanging,Other
|
492 |
+
needs fixing,Minor in-service problems
|
493 |
+
detached,Minor in-service problems
|
494 |
+
brokenmissing,Breakdown
|
495 |
+
need repacking,Minor in-service problems
|
496 |
+
wont pump to,Breakdown
|
497 |
+
sce fault,Fail to function
|
498 |
+
wont run,Failure to start on demand
|
499 |
+
requires modifying,Minor in-service problems
|
500 |
+
requires replacement,Minor in-service problems
|
501 |
+
triped,Electrical
|
502 |
+
stopping randomly,Spurious stop
|