arjun.a
commit
b24351f
raw
history blame
749 Bytes
BQ24196: Why Sys has a drop voltage
Part Number: BQ24196 Hi Team, My customer now use BQ24196. When they connected with battery, it is normal and no voltage dropped. When they don't connect with battery, SYS has a voltage dropped when 3.3V power up but no load in 3.3V. I asked them to add SYS output cap bigger. Do you have more suggestion? Thanks!
Hi, What is channel 3 (blue)? BTW, Please visit <secret URL>/support/power-management/f/196/t/877725 for BQ2419X: Schematic Review and PCB Layout Design Tips and <secret URL>/support/power-management/f/196/t/875388 for BQ2419X/2429x FAQs.BQ24196 is similar to BQ24192. Thanks, Ning.
Hi, We haven’t heard back from you for a while, the thread is considered solved and closed. Thanks, Ning.