ID: 5532050, Summary: C1+ CV01 - Open phase faults during vehicle integration, State: ALM_Analysed, Project: /Steering/Projects/ZF/PR52697_Global_Support_to_Division_T_GenC1Plus, Company: ZF, Team: 3550602, Classification: Incident / Problem / Bug, Comments: , Description: D2 Problem Description (R: PRE): During Vehicle integration, open phase faults have been observed Requirement which is violated (R: Originator): Expected behavior (R: Originator): Operating Environment (R: Originator): Test case identification (R: Originator): D3 Established Interim Containment Action (R: PRE): n/a D4a Verified Root Cause (R: PRE): Open phase faults: Current control tune parameters incorrect (no EPP current control tuning performed) D4b Verified Escape Point (R: PRE): Logged Data (DTC Readout/CAN Log/PAR File)(R: Originator): PCA: Current control tune to be performed after Dyno4 is operational in BVP D7 Lessons Learned (R: PRE):, Conclusion: The solution was proposed in the attachment and consists in the current controller gain increase, as they were incorrect. The current controller parameters have been updated in the .par file at the end of July. So far, the issue has not been seen again. The following parameters have been updated: MotorTune.EDCCoreMotorTune.EdcDetrCurCtrl.iCtrlrQuadAxisIntglGainMapMotorTune.EDCCoreMotorTune.EdcDetrCurCtrl.iCtrlrQuadAxisPropGainMapMotorTune.EDCCoreMotorTune.EdcDetrCurCtrl.iCtrlrDrctAxisIntglGainMapMotorTune.EDCCoreMotorTune.EdcDetrCurCtrl.iCtrlrDrctAxisPropGainMap More details in the attached message., LogType: Fault Detection Log
ID: 5532050
Provide the details for the given ID
ID: 5532050, Summary: C1+ CV01 - Open phase faults during vehicle integration, State: ALM_Analysed, Project: /Steering/Projects/ZF/PR52697_Global_Support_to_Division_T_GenC1Plus, Company: ZF, Team: 3550602, Classification: Incident / Problem / Bug, Comments: , Description: D2 Problem Description (R: PRE): During Vehicle integration, open phase faults have been observed Requirement which is violated (R: Originator): Expected behavior (R: Originator): Operating Environment (R: Originator): Test case identification (R: Originator): D3 Established Interim Containment Action (R: PRE): n/a D4a Verified Root Cause (R: PRE): Open phase faults: Current control tune parameters incorrect (no EPP current control tuning performed) D4b Verified Escape Point (R: PRE): Logged Data (DTC Readout/CAN Log/PAR File)(R: Originator): PCA: Current control tune to be performed after Dyno4 is operational in BVP D7 Lessons Learned (R: PRE):, Conclusion: The solution was proposed in the attachment and consists in the current controller gain increase, as they were incorrect. The current controller parameters have been updated in the .par file at the end of July. So far, the issue has not been seen again. The following parameters have been updated: MotorTune.EDCCoreMotorTune.EdcDetrCurCtrl.iCtrlrQuadAxisIntglGainMapMotorTune.EDCCoreMotorTune.EdcDetrCurCtrl.iCtrlrQuadAxisPropGainMapMotorTune.EDCCoreMotorTune.EdcDetrCurCtrl.iCtrlrDrctAxisIntglGainMapMotorTune.EDCCoreMotorTune.EdcDetrCurCtrl.iCtrlrDrctAxisPropGainMap More details in the attached message., LogType: Fault Detection Log
Summary: C1+ CV01 - Open phase faults during vehicle integration
Provide the details for the given Summary
ID: 5532050, Summary: C1+ CV01 - Open phase faults during vehicle integration, State: ALM_Analysed, Project: /Steering/Projects/ZF/PR52697_Global_Support_to_Division_T_GenC1Plus, Company: ZF, Team: 3550602, Classification: Incident / Problem / Bug, Comments: , Description: D2 Problem Description (R: PRE): During Vehicle integration, open phase faults have been observed Requirement which is violated (R: Originator): Expected behavior (R: Originator): Operating Environment (R: Originator): Test case identification (R: Originator): D3 Established Interim Containment Action (R: PRE): n/a D4a Verified Root Cause (R: PRE): Open phase faults: Current control tune parameters incorrect (no EPP current control tuning performed) D4b Verified Escape Point (R: PRE): Logged Data (DTC Readout/CAN Log/PAR File)(R: Originator): PCA: Current control tune to be performed after Dyno4 is operational in BVP D7 Lessons Learned (R: PRE):, Conclusion: The solution was proposed in the attachment and consists in the current controller gain increase, as they were incorrect. The current controller parameters have been updated in the .par file at the end of July. So far, the issue has not been seen again. The following parameters have been updated: MotorTune.EDCCoreMotorTune.EdcDetrCurCtrl.iCtrlrQuadAxisIntglGainMapMotorTune.EDCCoreMotorTune.EdcDetrCurCtrl.iCtrlrQuadAxisPropGainMapMotorTune.EDCCoreMotorTune.EdcDetrCurCtrl.iCtrlrDrctAxisIntglGainMapMotorTune.EDCCoreMotorTune.EdcDetrCurCtrl.iCtrlrDrctAxisPropGainMap More details in the attached message., LogType: Fault Detection Log
LogType: Fault Detection Log, Company: ZF, Summary: C1+ CV01 - Open phase faults during vehicle integration
Provide the details for the given input
ID: 5532549, Summary: [Opel K0][Requirement] - Drop and replace SSM_PB related modules, State: ALM_Realized, Project: /SCS/Customer/PSA/K0, Company: PSA, Team: 3544056, Classification: Requirements, Comments: , Description: SWPM - SKO (21.07.21 - 13:47)Brief investigation comment:After latest branch from VW it is identified that some of SSM_PB related modules need to be updated as shown below: Drop and replace the yellow highlighted modules? Instead the following modules shall be shared from BrkSW – POOL into the PSA k0 1.3 of And , Conclusion: Brief analysis summary:Need to drop the sub components Ssm_Pbi and SsmPbWrp from Opel K0 - EPBi Folder and share it from BrkSW Pool.TASKDrop the Ssm_Pbi and SsmPbWrp components from the below Repository location path /SCS#Customer/PSA/K0/05_Software/VIEW_Mainline/MMC_APPL/MMC_APPL_SW/Application/EPBi/project.pj Share Ssm_Pbi & SsmPbWrp from BrkSW repository location /BrkSw/SwDevelopmentPool/Software/Components/Ssm_Pbi/project.pj- Checkpoint 1.9.2.1 /BrkSw/SwDevelopmentPool/Software/Components/SsmPbWrp/project.pj- Checkpoint 1.3 Acceptance criteria: After sharing the new sub components verify the compilation check. Owner: Sravan Kumar AkojuReviewer: Mehta Jay Estimated design effort/h: 1hrEstimated implementation effort/h: 3hrEstimated unit testing effort/h: 0, LogType: Requirement Log
ID: 5532549
Provide the details for the given ID
ID: 5532549, Summary: [Opel K0][Requirement] - Drop and replace SSM_PB related modules, State: ALM_Realized, Project: /SCS/Customer/PSA/K0, Company: PSA, Team: 3544056, Classification: Requirements, Comments: , Description: SWPM - SKO (21.07.21 - 13:47)Brief investigation comment:After latest branch from VW it is identified that some of SSM_PB related modules need to be updated as shown below: Drop and replace the yellow highlighted modules? Instead the following modules shall be shared from BrkSW – POOL into the PSA k0 1.3 of And , Conclusion: Brief analysis summary:Need to drop the sub components Ssm_Pbi and SsmPbWrp from Opel K0 - EPBi Folder and share it from BrkSW Pool.TASKDrop the Ssm_Pbi and SsmPbWrp components from the below Repository location path /SCS#Customer/PSA/K0/05_Software/VIEW_Mainline/MMC_APPL/MMC_APPL_SW/Application/EPBi/project.pj Share Ssm_Pbi & SsmPbWrp from BrkSW repository location /BrkSw/SwDevelopmentPool/Software/Components/Ssm_Pbi/project.pj- Checkpoint 1.9.2.1 /BrkSw/SwDevelopmentPool/Software/Components/SsmPbWrp/project.pj- Checkpoint 1.3 Acceptance criteria: After sharing the new sub components verify the compilation check. Owner: Sravan Kumar AkojuReviewer: Mehta Jay Estimated design effort/h: 1hrEstimated implementation effort/h: 3hrEstimated unit testing effort/h: 0, LogType: Requirement Log
Summary: [Opel K0][Requirement] - Drop and replace SSM_PB related modules
Provide the details for the given Summary
ID: 5532549, Summary: [Opel K0][Requirement] - Drop and replace SSM_PB related modules, State: ALM_Realized, Project: /SCS/Customer/PSA/K0, Company: PSA, Team: 3544056, Classification: Requirements, Comments: , Description: SWPM - SKO (21.07.21 - 13:47)Brief investigation comment:After latest branch from VW it is identified that some of SSM_PB related modules need to be updated as shown below: Drop and replace the yellow highlighted modules? Instead the following modules shall be shared from BrkSW – POOL into the PSA k0 1.3 of And , Conclusion: Brief analysis summary:Need to drop the sub components Ssm_Pbi and SsmPbWrp from Opel K0 - EPBi Folder and share it from BrkSW Pool.TASKDrop the Ssm_Pbi and SsmPbWrp components from the below Repository location path /SCS#Customer/PSA/K0/05_Software/VIEW_Mainline/MMC_APPL/MMC_APPL_SW/Application/EPBi/project.pj Share Ssm_Pbi & SsmPbWrp from BrkSW repository location /BrkSw/SwDevelopmentPool/Software/Components/Ssm_Pbi/project.pj- Checkpoint 1.9.2.1 /BrkSw/SwDevelopmentPool/Software/Components/SsmPbWrp/project.pj- Checkpoint 1.3 Acceptance criteria: After sharing the new sub components verify the compilation check. Owner: Sravan Kumar AkojuReviewer: Mehta Jay Estimated design effort/h: 1hrEstimated implementation effort/h: 3hrEstimated unit testing effort/h: 0, LogType: Requirement Log
LogType: Requirement Log, Company: PSA, Summary: [Opel K0][Requirement] - Drop and replace SSM_PB related modules
Provide the details for the given input
ID: 5532680, Summary: [0521][CASE][VW_MEB41x_SCS]MCP oscillations cause HBA exit and HBA triggering, State: ALM_Closed, Project: /BRK/Customer/VW/ID_Buzz/ESC, Company: VW, Team: 3361822, Classification: Incident / Problem / Bug, Comments: , Description: Preconditions / Ausgangsituation: Vehicle: AERO / ID.Buzz054 / ID.Buzz089SW SCS: M521 /b521SW EBB: 657-002 / b651Maneuver name: HBAActions / Aktionen:1. HBA triggering2. xxx3. xxx4. xxx5. xxxExpected Behavior / erwartetes Sollverhalten:HBA should stay active / HBA should not become active without driver intentActual Behavior / Istverhalten:2021-07-01_AERO_009_248.MDF2021-07-13_ID.BUZZ054_299.MDF> HBA exit (DEACT9) due to MCP oscillations 2021-07-20_ID.BUZZ089_299.MDF> HBA triggered again without driver intent (caused by MCP oscillaions) Oscillations are also seen in analog pressure measurement circuit 1 and 2 Requirement ID not fullfilled (if known)/ Lastenheft ID nicht erfuellt (wenn bekannt):xxxImpact / Einfluss:xxx, Conclusion: Conclusion taken over from spawned CR with first change regarding this topic: [31.08.2021], E. Webert:- Soll dieses Änderung noch für den MEB Classic erfolgen? Ja, sonst sind Kundenbeanstandungen zu erwarten (Pedalrückwirkungen)- Für welche SW? Geplant für X523 => Wann ist die X523?- Frage aus dem CCB mit VW: Tritt es auch bei anderen Boost-Funktionen oder der HVV (Hinterachsvollverzögerung) auf? Sollte man auch bei weiteren Funktionen Pedalkraftkompensation abschalten?- HVV heißt bei uns RAxB (vgl. Mail im Anhang AW_ OP 5532680 - _0521__CASE__VW_MEB41x_SCS_MCP oscillations cause HBA exit and HBA triggering_CBecker.msg)- Wir gucken auf den ARB-Mode BRK_CTRL_ARB_BRAKE_ASSIST und dieser Mode deckt nicht nur HBA ab, sondern alle HBX-Funktionen (HBA, HBB, DBK, RAxB, RAB [Prefill])- Heißt wir brauchen keine weiteren Ausnahmen.[13.09.2021], E. Webert:- es muss eine weitere Ausnahme erfolgen- vgl. dazu CR 5703695 - RB: Pedalflattern im Stillstand (HBA und PFC im Stillstand)- die Logik wird mit der 2. Task eingecheckt => Task 5705543 [04.10.2021], E. Webert:- Unklar, ob die Änderung das Problem löst- laut weiteren Analysen kommt es zu einem nicht gewünschten Verhalten aufgrund einer Logik im ARB (MAX-Bildung bei SSM?)- Man sollte versuchen es vorher im ARB zu lösen, dann kann dieses CR rejectet werden- auf Feedback warten [04.11.2021], E. Webert:- vg. Mail im Anhang: AW_ noch offene OP-Bewertung für die anstehende CAT5.msg- laut CASE soll für MEB Classic erstmal keine Lösung erfolgen- für UN ECE soll es neue bewertet werden => teilweise gibt es Lösungsvorschläge für einen Fix im ARB => Mail im Anhang: WG Analyse Anregungen nach HBB.msg- Punkt wird rejectet, LogType: Other
ID: 5532680
Provide the details for the given ID
ID: 5532680, Summary: [0521][CASE][VW_MEB41x_SCS]MCP oscillations cause HBA exit and HBA triggering, State: ALM_Closed, Project: /BRK/Customer/VW/ID_Buzz/ESC, Company: VW, Team: 3361822, Classification: Incident / Problem / Bug, Comments: , Description: Preconditions / Ausgangsituation: Vehicle: AERO / ID.Buzz054 / ID.Buzz089SW SCS: M521 /b521SW EBB: 657-002 / b651Maneuver name: HBAActions / Aktionen:1. HBA triggering2. xxx3. xxx4. xxx5. xxxExpected Behavior / erwartetes Sollverhalten:HBA should stay active / HBA should not become active without driver intentActual Behavior / Istverhalten:2021-07-01_AERO_009_248.MDF2021-07-13_ID.BUZZ054_299.MDF> HBA exit (DEACT9) due to MCP oscillations 2021-07-20_ID.BUZZ089_299.MDF> HBA triggered again without driver intent (caused by MCP oscillaions) Oscillations are also seen in analog pressure measurement circuit 1 and 2 Requirement ID not fullfilled (if known)/ Lastenheft ID nicht erfuellt (wenn bekannt):xxxImpact / Einfluss:xxx, Conclusion: Conclusion taken over from spawned CR with first change regarding this topic: [31.08.2021], E. Webert:- Soll dieses Änderung noch für den MEB Classic erfolgen? Ja, sonst sind Kundenbeanstandungen zu erwarten (Pedalrückwirkungen)- Für welche SW? Geplant für X523 => Wann ist die X523?- Frage aus dem CCB mit VW: Tritt es auch bei anderen Boost-Funktionen oder der HVV (Hinterachsvollverzögerung) auf? Sollte man auch bei weiteren Funktionen Pedalkraftkompensation abschalten?- HVV heißt bei uns RAxB (vgl. Mail im Anhang AW_ OP 5532680 - _0521__CASE__VW_MEB41x_SCS_MCP oscillations cause HBA exit and HBA triggering_CBecker.msg)- Wir gucken auf den ARB-Mode BRK_CTRL_ARB_BRAKE_ASSIST und dieser Mode deckt nicht nur HBA ab, sondern alle HBX-Funktionen (HBA, HBB, DBK, RAxB, RAB [Prefill])- Heißt wir brauchen keine weiteren Ausnahmen.[13.09.2021], E. Webert:- es muss eine weitere Ausnahme erfolgen- vgl. dazu CR 5703695 - RB: Pedalflattern im Stillstand (HBA und PFC im Stillstand)- die Logik wird mit der 2. Task eingecheckt => Task 5705543 [04.10.2021], E. Webert:- Unklar, ob die Änderung das Problem löst- laut weiteren Analysen kommt es zu einem nicht gewünschten Verhalten aufgrund einer Logik im ARB (MAX-Bildung bei SSM?)- Man sollte versuchen es vorher im ARB zu lösen, dann kann dieses CR rejectet werden- auf Feedback warten [04.11.2021], E. Webert:- vg. Mail im Anhang: AW_ noch offene OP-Bewertung für die anstehende CAT5.msg- laut CASE soll für MEB Classic erstmal keine Lösung erfolgen- für UN ECE soll es neue bewertet werden => teilweise gibt es Lösungsvorschläge für einen Fix im ARB => Mail im Anhang: WG Analyse Anregungen nach HBB.msg- Punkt wird rejectet, LogType: Other
Summary: [0521][CASE][VW_MEB41x_SCS]MCP oscillations cause HBA exit and HBA triggering
Provide the details for the given Summary
ID: 5532680, Summary: [0521][CASE][VW_MEB41x_SCS]MCP oscillations cause HBA exit and HBA triggering, State: ALM_Closed, Project: /BRK/Customer/VW/ID_Buzz/ESC, Company: VW, Team: 3361822, Classification: Incident / Problem / Bug, Comments: , Description: Preconditions / Ausgangsituation: Vehicle: AERO / ID.Buzz054 / ID.Buzz089SW SCS: M521 /b521SW EBB: 657-002 / b651Maneuver name: HBAActions / Aktionen:1. HBA triggering2. xxx3. xxx4. xxx5. xxxExpected Behavior / erwartetes Sollverhalten:HBA should stay active / HBA should not become active without driver intentActual Behavior / Istverhalten:2021-07-01_AERO_009_248.MDF2021-07-13_ID.BUZZ054_299.MDF> HBA exit (DEACT9) due to MCP oscillations 2021-07-20_ID.BUZZ089_299.MDF> HBA triggered again without driver intent (caused by MCP oscillaions) Oscillations are also seen in analog pressure measurement circuit 1 and 2 Requirement ID not fullfilled (if known)/ Lastenheft ID nicht erfuellt (wenn bekannt):xxxImpact / Einfluss:xxx, Conclusion: Conclusion taken over from spawned CR with first change regarding this topic: [31.08.2021], E. Webert:- Soll dieses Änderung noch für den MEB Classic erfolgen? Ja, sonst sind Kundenbeanstandungen zu erwarten (Pedalrückwirkungen)- Für welche SW? Geplant für X523 => Wann ist die X523?- Frage aus dem CCB mit VW: Tritt es auch bei anderen Boost-Funktionen oder der HVV (Hinterachsvollverzögerung) auf? Sollte man auch bei weiteren Funktionen Pedalkraftkompensation abschalten?- HVV heißt bei uns RAxB (vgl. Mail im Anhang AW_ OP 5532680 - _0521__CASE__VW_MEB41x_SCS_MCP oscillations cause HBA exit and HBA triggering_CBecker.msg)- Wir gucken auf den ARB-Mode BRK_CTRL_ARB_BRAKE_ASSIST und dieser Mode deckt nicht nur HBA ab, sondern alle HBX-Funktionen (HBA, HBB, DBK, RAxB, RAB [Prefill])- Heißt wir brauchen keine weiteren Ausnahmen.[13.09.2021], E. Webert:- es muss eine weitere Ausnahme erfolgen- vgl. dazu CR 5703695 - RB: Pedalflattern im Stillstand (HBA und PFC im Stillstand)- die Logik wird mit der 2. Task eingecheckt => Task 5705543 [04.10.2021], E. Webert:- Unklar, ob die Änderung das Problem löst- laut weiteren Analysen kommt es zu einem nicht gewünschten Verhalten aufgrund einer Logik im ARB (MAX-Bildung bei SSM?)- Man sollte versuchen es vorher im ARB zu lösen, dann kann dieses CR rejectet werden- auf Feedback warten [04.11.2021], E. Webert:- vg. Mail im Anhang: AW_ noch offene OP-Bewertung für die anstehende CAT5.msg- laut CASE soll für MEB Classic erstmal keine Lösung erfolgen- für UN ECE soll es neue bewertet werden => teilweise gibt es Lösungsvorschläge für einen Fix im ARB => Mail im Anhang: WG Analyse Anregungen nach HBB.msg- Punkt wird rejectet, LogType: Other
LogType: Other, Company: VW, Summary: [0521][CASE][VW_MEB41x_SCS]MCP oscillations cause HBA exit and HBA triggering
Provide the details for the given input
ID: 5532710, Summary: HKMC_SK PE | FA00 | SWE5 | DTC&MIL Mapping Test - DTC&MIL mapping fails or inconsistencies between FSM and the code , State: ALM_Closed, Project: /Steering/Projects/HKMC/SK/PR45616_MY2018_HKMC_SK_EPS_CD_Hroom_AP, Company: HKMC, Team: 1963171, Classification: Incident / Problem / Bug, Comments: , Description: Activity Description:With the outcome from W130j as Impact Analysis results on SWE1 per one clustered change from this release and one build, the change impacted features and behaviors identified and determined, SW Requriement Project Manager arrange Feature manager or Funciton Developers to Generate SW Requriements by following below Task scope and ZF procedures and steps:(Notes: Due to specific change may derives tailored activities from Impact Analysis on below full activity scope, therefore the actual activities tailor status of the Task to be described by Task Responsible in this Task Notes area, per Review activity description, it need performed in connected review Task Conclusion area due to the main Task Notes area can't be updated while in Reivew phase)Task Scope:Feature:Behavior:Process following:1. Develop Behaviour Requirements (C_066_2_SSE_002_EN_SoftwareRequirementsAnalysis defines general)1.1 Write SW Requirements with bleow sub steps which follows C_066_3_SSE_025_EN Write SW Requirements Work Instruction:3.1. Processing Collected Software Requirements3.2. Manage Requirements and Traceability3.3. Software Requirements Style3.4. Handling of software requirement sources3.5. Handling of Signals and Parameters for software requirements3.6. Handling of Attributes for software requirementsAttributes shall be set according to the work instruction C_066_3_SSE_026_EN_SW_Attributes1.2 ?Assign SW Releases for SW Requirements with below sub steps which follows C_066_3_SSE_020_EN Assign SW Releases for SW Requirements Work Instruction:3.1. Add SW release to a requirement3.2. Removing a SW release from a requirement3.3. Maintaining requirements assigned to multiple SW releases – functional change3.4. Maintaining requirements assigned to multiple SW releases – no functional change3.5. Maintaining requirements assigned to multiple SW releases – bug fix2. Review Software Requirements (C_066_2_SSE_002_EN_SoftwareRequirementsAnalysis defines general)Organise a Software Requirements Review performed with below sub steps and follows C_066_3_SSE_029_EN Organise a Software Requirements Review Work Instruction:3.1. Organize a formal software requirements review3.1.1. Prepare the review of software requirements3.1.2. Perform technical and formal review3.1.3. Organize Review by stakeholder3.1.4. Stakeholder Review3.1.5. Finalize SW Requirements review3.2. Organize an informal software requirements review4. Review invitationInput for this WP are:?1. SW Release Plan2. System Requirement & Architecture (Compliance Analyzed)3. ECU HW design spec (Compliance Analyzed)4. Customer Requirement (Compliance Analyzed)5. Impact Analysis6. SW engineering traceability matrix?Output of this WP:1. SW Requirement2. SW Requirement Baseline3. FSF Manual (Updates)Responsible: SW Feature Manager, SW FM DeveloperSupport: SW Requirement Porject Manager, SWPM, SW Safety Engineer, SW Test Enineer ?, Conclusion: Change to Analysed, LogType: Other
ID: 5532710
Provide the details for the given ID
ID: 5532710, Summary: HKMC_SK PE | FA00 | SWE5 | DTC&MIL Mapping Test - DTC&MIL mapping fails or inconsistencies between FSM and the code , State: ALM_Closed, Project: /Steering/Projects/HKMC/SK/PR45616_MY2018_HKMC_SK_EPS_CD_Hroom_AP, Company: HKMC, Team: 1963171, Classification: Incident / Problem / Bug, Comments: , Description: Activity Description:With the outcome from W130j as Impact Analysis results on SWE1 per one clustered change from this release and one build, the change impacted features and behaviors identified and determined, SW Requriement Project Manager arrange Feature manager or Funciton Developers to Generate SW Requriements by following below Task scope and ZF procedures and steps:(Notes: Due to specific change may derives tailored activities from Impact Analysis on below full activity scope, therefore the actual activities tailor status of the Task to be described by Task Responsible in this Task Notes area, per Review activity description, it need performed in connected review Task Conclusion area due to the main Task Notes area can't be updated while in Reivew phase)Task Scope:Feature:Behavior:Process following:1. Develop Behaviour Requirements (C_066_2_SSE_002_EN_SoftwareRequirementsAnalysis defines general)1.1 Write SW Requirements with bleow sub steps which follows C_066_3_SSE_025_EN Write SW Requirements Work Instruction:3.1. Processing Collected Software Requirements3.2. Manage Requirements and Traceability3.3. Software Requirements Style3.4. Handling of software requirement sources3.5. Handling of Signals and Parameters for software requirements3.6. Handling of Attributes for software requirementsAttributes shall be set according to the work instruction C_066_3_SSE_026_EN_SW_Attributes1.2 ?Assign SW Releases for SW Requirements with below sub steps which follows C_066_3_SSE_020_EN Assign SW Releases for SW Requirements Work Instruction:3.1. Add SW release to a requirement3.2. Removing a SW release from a requirement3.3. Maintaining requirements assigned to multiple SW releases – functional change3.4. Maintaining requirements assigned to multiple SW releases – no functional change3.5. Maintaining requirements assigned to multiple SW releases – bug fix2. Review Software Requirements (C_066_2_SSE_002_EN_SoftwareRequirementsAnalysis defines general)Organise a Software Requirements Review performed with below sub steps and follows C_066_3_SSE_029_EN Organise a Software Requirements Review Work Instruction:3.1. Organize a formal software requirements review3.1.1. Prepare the review of software requirements3.1.2. Perform technical and formal review3.1.3. Organize Review by stakeholder3.1.4. Stakeholder Review3.1.5. Finalize SW Requirements review3.2. Organize an informal software requirements review4. Review invitationInput for this WP are:?1. SW Release Plan2. System Requirement & Architecture (Compliance Analyzed)3. ECU HW design spec (Compliance Analyzed)4. Customer Requirement (Compliance Analyzed)5. Impact Analysis6. SW engineering traceability matrix?Output of this WP:1. SW Requirement2. SW Requirement Baseline3. FSF Manual (Updates)Responsible: SW Feature Manager, SW FM DeveloperSupport: SW Requirement Porject Manager, SWPM, SW Safety Engineer, SW Test Enineer ?, Conclusion: Change to Analysed, LogType: Other
Summary: HKMC_SK PE | FA00 | SWE5 | DTC&MIL Mapping Test - DTC&MIL mapping fails or inconsistencies between FSM and the code
Provide the details for the given Summary
ID: 5532710, Summary: HKMC_SK PE | FA00 | SWE5 | DTC&MIL Mapping Test - DTC&MIL mapping fails or inconsistencies between FSM and the code , State: ALM_Closed, Project: /Steering/Projects/HKMC/SK/PR45616_MY2018_HKMC_SK_EPS_CD_Hroom_AP, Company: HKMC, Team: 1963171, Classification: Incident / Problem / Bug, Comments: , Description: Activity Description:With the outcome from W130j as Impact Analysis results on SWE1 per one clustered change from this release and one build, the change impacted features and behaviors identified and determined, SW Requriement Project Manager arrange Feature manager or Funciton Developers to Generate SW Requriements by following below Task scope and ZF procedures and steps:(Notes: Due to specific change may derives tailored activities from Impact Analysis on below full activity scope, therefore the actual activities tailor status of the Task to be described by Task Responsible in this Task Notes area, per Review activity description, it need performed in connected review Task Conclusion area due to the main Task Notes area can't be updated while in Reivew phase)Task Scope:Feature:Behavior:Process following:1. Develop Behaviour Requirements (C_066_2_SSE_002_EN_SoftwareRequirementsAnalysis defines general)1.1 Write SW Requirements with bleow sub steps which follows C_066_3_SSE_025_EN Write SW Requirements Work Instruction:3.1. Processing Collected Software Requirements3.2. Manage Requirements and Traceability3.3. Software Requirements Style3.4. Handling of software requirement sources3.5. Handling of Signals and Parameters for software requirements3.6. Handling of Attributes for software requirementsAttributes shall be set according to the work instruction C_066_3_SSE_026_EN_SW_Attributes1.2 ?Assign SW Releases for SW Requirements with below sub steps which follows C_066_3_SSE_020_EN Assign SW Releases for SW Requirements Work Instruction:3.1. Add SW release to a requirement3.2. Removing a SW release from a requirement3.3. Maintaining requirements assigned to multiple SW releases – functional change3.4. Maintaining requirements assigned to multiple SW releases – no functional change3.5. Maintaining requirements assigned to multiple SW releases – bug fix2. Review Software Requirements (C_066_2_SSE_002_EN_SoftwareRequirementsAnalysis defines general)Organise a Software Requirements Review performed with below sub steps and follows C_066_3_SSE_029_EN Organise a Software Requirements Review Work Instruction:3.1. Organize a formal software requirements review3.1.1. Prepare the review of software requirements3.1.2. Perform technical and formal review3.1.3. Organize Review by stakeholder3.1.4. Stakeholder Review3.1.5. Finalize SW Requirements review3.2. Organize an informal software requirements review4. Review invitationInput for this WP are:?1. SW Release Plan2. System Requirement & Architecture (Compliance Analyzed)3. ECU HW design spec (Compliance Analyzed)4. Customer Requirement (Compliance Analyzed)5. Impact Analysis6. SW engineering traceability matrix?Output of this WP:1. SW Requirement2. SW Requirement Baseline3. FSF Manual (Updates)Responsible: SW Feature Manager, SW FM DeveloperSupport: SW Requirement Porject Manager, SWPM, SW Safety Engineer, SW Test Enineer ?, Conclusion: Change to Analysed, LogType: Other
LogType: Other, Company: HKMC, Summary: HKMC_SK PE | FA00 | SWE5 | DTC&MIL Mapping Test - DTC&MIL mapping fails or inconsistencies between FSM and the code
Provide the details for the given input
ID: 5532752, Summary: [Issue] of PBC_040 - SIL Test - Actuator change to Unknown at RAR and HostAvailability NONE/APPLY/RELEASE, before RAR or Parkapply, State: ALM_Closed, Project: /EPB/CustomerDevelopment/Ford/P708-eDIH-Livonia, Company: CustomerDevelopment, Team: , Classification: Incident / Problem / Bug, Comments: , Description: Preconditions:Init with Fully released actuators. Close to Parkapplied, Set PbcIn.HostavailabilityRl/Rr/Both = None OR Relase OR Apply.Action:Set Wheespeed to 3 km/h or perform a parkapplyExpected Behaviour: Good side perform a RAR.Bad side MotorCommad not move to any state.Actual behaviour: Good side perform a RAR. bad side set PbcOut.MotorCommad = Apply(Stop/None one for cycle, and set PbcOut.ActuatorState to ePbcActuatorStateUnknown11/1/21: Analzed by Lubbers with changes made to Design Document.Further Information: Same behaviour with undervoltage and parkapply. Only left side try to start an actuation. This behaviour seems to be strange.Please see attachment, Conclusion: EPB System CCB - JAS - 11.08.21:Please investigate this point and advise the next steps., LogType: Other
ID: 5532752
Provide the details for the given ID
ID: 5532752, Summary: [Issue] of PBC_040 - SIL Test - Actuator change to Unknown at RAR and HostAvailability NONE/APPLY/RELEASE, before RAR or Parkapply, State: ALM_Closed, Project: /EPB/CustomerDevelopment/Ford/P708-eDIH-Livonia, Company: CustomerDevelopment, Team: , Classification: Incident / Problem / Bug, Comments: , Description: Preconditions:Init with Fully released actuators. Close to Parkapplied, Set PbcIn.HostavailabilityRl/Rr/Both = None OR Relase OR Apply.Action:Set Wheespeed to 3 km/h or perform a parkapplyExpected Behaviour: Good side perform a RAR.Bad side MotorCommad not move to any state.Actual behaviour: Good side perform a RAR. bad side set PbcOut.MotorCommad = Apply(Stop/None one for cycle, and set PbcOut.ActuatorState to ePbcActuatorStateUnknown11/1/21: Analzed by Lubbers with changes made to Design Document.Further Information: Same behaviour with undervoltage and parkapply. Only left side try to start an actuation. This behaviour seems to be strange.Please see attachment, Conclusion: EPB System CCB - JAS - 11.08.21:Please investigate this point and advise the next steps., LogType: Other
Summary: [Issue] of PBC_040 - SIL Test - Actuator change to Unknown at RAR and HostAvailability NONE/APPLY/RELEASE, before RAR or Parkapply
Provide the details for the given Summary
ID: 5532752, Summary: [Issue] of PBC_040 - SIL Test - Actuator change to Unknown at RAR and HostAvailability NONE/APPLY/RELEASE, before RAR or Parkapply, State: ALM_Closed, Project: /EPB/CustomerDevelopment/Ford/P708-eDIH-Livonia, Company: CustomerDevelopment, Team: , Classification: Incident / Problem / Bug, Comments: , Description: Preconditions:Init with Fully released actuators. Close to Parkapplied, Set PbcIn.HostavailabilityRl/Rr/Both = None OR Relase OR Apply.Action:Set Wheespeed to 3 km/h or perform a parkapplyExpected Behaviour: Good side perform a RAR.Bad side MotorCommad not move to any state.Actual behaviour: Good side perform a RAR. bad side set PbcOut.MotorCommad = Apply(Stop/None one for cycle, and set PbcOut.ActuatorState to ePbcActuatorStateUnknown11/1/21: Analzed by Lubbers with changes made to Design Document.Further Information: Same behaviour with undervoltage and parkapply. Only left side try to start an actuation. This behaviour seems to be strange.Please see attachment, Conclusion: EPB System CCB - JAS - 11.08.21:Please investigate this point and advise the next steps., LogType: Other
LogType: Other, Company: CustomerDevelopment, Summary: [Issue] of PBC_040 - SIL Test - Actuator change to Unknown at RAR and HostAvailability NONE/APPLY/RELEASE, before RAR or Parkapply
Provide the details for the given input
ID: 5532782, Summary: [Issue] of PBC_040 - SIL Test - Actuation stops even if actuation is possible due to change of Hostavailablity , State: ALM_Closed, Project: /EPB/CustomerDevelopment/Ford/P708-eDIH-Livonia, Company: CustomerDevelopment, Team: , Classification: Incident / Problem / Bug, Comments: , Description: Preconditions: Init with Fully released actuators.Action: Apply or Release, Set PbcInHostavailability to apply if acatuation is in apply direction or release if actuation is in release direction.Expected Behaviour: Actuation is finishedActual behaviour: Actuation stops and affected actuator is unknownFurther Information/Requirements: If actuation is possible shall not stop..Please see attachment 1/11/21: Analyzed by Mark Lubbers. Changes made to Design Document., Conclusion: EPB System CCB - JAS - 11.08.21:Please investigate this point and advise the next steps., LogType: Other
ID: 5532782
Provide the details for the given ID
ID: 5532782, Summary: [Issue] of PBC_040 - SIL Test - Actuation stops even if actuation is possible due to change of Hostavailablity , State: ALM_Closed, Project: /EPB/CustomerDevelopment/Ford/P708-eDIH-Livonia, Company: CustomerDevelopment, Team: , Classification: Incident / Problem / Bug, Comments: , Description: Preconditions: Init with Fully released actuators.Action: Apply or Release, Set PbcInHostavailability to apply if acatuation is in apply direction or release if actuation is in release direction.Expected Behaviour: Actuation is finishedActual behaviour: Actuation stops and affected actuator is unknownFurther Information/Requirements: If actuation is possible shall not stop..Please see attachment 1/11/21: Analyzed by Mark Lubbers. Changes made to Design Document., Conclusion: EPB System CCB - JAS - 11.08.21:Please investigate this point and advise the next steps., LogType: Other
Summary: [Issue] of PBC_040 - SIL Test - Actuation stops even if actuation is possible due to change of Hostavailablity
Provide the details for the given Summary
ID: 5532782, Summary: [Issue] of PBC_040 - SIL Test - Actuation stops even if actuation is possible due to change of Hostavailablity , State: ALM_Closed, Project: /EPB/CustomerDevelopment/Ford/P708-eDIH-Livonia, Company: CustomerDevelopment, Team: , Classification: Incident / Problem / Bug, Comments: , Description: Preconditions: Init with Fully released actuators.Action: Apply or Release, Set PbcInHostavailability to apply if acatuation is in apply direction or release if actuation is in release direction.Expected Behaviour: Actuation is finishedActual behaviour: Actuation stops and affected actuator is unknownFurther Information/Requirements: If actuation is possible shall not stop..Please see attachment 1/11/21: Analyzed by Mark Lubbers. Changes made to Design Document., Conclusion: EPB System CCB - JAS - 11.08.21:Please investigate this point and advise the next steps., LogType: Other
LogType: Other, Company: CustomerDevelopment, Summary: [Issue] of PBC_040 - SIL Test - Actuation stops even if actuation is possible due to change of Hostavailablity
Provide the details for the given input
ID: 5532789, Summary: [Issue] of PBC_040 - SIL Test - RAR perform with speed >= 15 km/h, State: ALM_Closed, Project: /EPB/CustomerDevelopment/Ford/P708-eDIH-Livonia, Company: CustomerDevelopment, Team: , Classification: Incident / Problem / Bug, Comments: , Description: Preconditions:Precondition for RARAction:Set all speeds >= 15 km/hExpected Behaviour: No RAR perfomedActual behaviour: RAR is performedFurther Information/Requirements: This threshold of 15km/h is the limit of RAR,because of HSB Vehicle safety speed. Maybe the HSB from Host will not enable the applyline and this will lead an internal fault. See VDA Chapter 3.1.2 HOST Safety Barrier Investigate possible difference between host and PBC ref speed calculation. SIL Test -130-304-PBC_RAR_BY_WHEEL_SPEED_15_KMH Please see attachment, Conclusion: EPB System CCB - JAS - 11.08.21:Please investigate this point and advise the next steps.12/02/21: Change Implemented per associated task., LogType: Other
ID: 5532789
Provide the details for the given ID
ID: 5532789, Summary: [Issue] of PBC_040 - SIL Test - RAR perform with speed >= 15 km/h, State: ALM_Closed, Project: /EPB/CustomerDevelopment/Ford/P708-eDIH-Livonia, Company: CustomerDevelopment, Team: , Classification: Incident / Problem / Bug, Comments: , Description: Preconditions:Precondition for RARAction:Set all speeds >= 15 km/hExpected Behaviour: No RAR perfomedActual behaviour: RAR is performedFurther Information/Requirements: This threshold of 15km/h is the limit of RAR,because of HSB Vehicle safety speed. Maybe the HSB from Host will not enable the applyline and this will lead an internal fault. See VDA Chapter 3.1.2 HOST Safety Barrier Investigate possible difference between host and PBC ref speed calculation. SIL Test -130-304-PBC_RAR_BY_WHEEL_SPEED_15_KMH Please see attachment, Conclusion: EPB System CCB - JAS - 11.08.21:Please investigate this point and advise the next steps.12/02/21: Change Implemented per associated task., LogType: Other
Summary: [Issue] of PBC_040 - SIL Test - RAR perform with speed >= 15 km/h
Provide the details for the given Summary
ID: 5532789, Summary: [Issue] of PBC_040 - SIL Test - RAR perform with speed >= 15 km/h, State: ALM_Closed, Project: /EPB/CustomerDevelopment/Ford/P708-eDIH-Livonia, Company: CustomerDevelopment, Team: , Classification: Incident / Problem / Bug, Comments: , Description: Preconditions:Precondition for RARAction:Set all speeds >= 15 km/hExpected Behaviour: No RAR perfomedActual behaviour: RAR is performedFurther Information/Requirements: This threshold of 15km/h is the limit of RAR,because of HSB Vehicle safety speed. Maybe the HSB from Host will not enable the applyline and this will lead an internal fault. See VDA Chapter 3.1.2 HOST Safety Barrier Investigate possible difference between host and PBC ref speed calculation. SIL Test -130-304-PBC_RAR_BY_WHEEL_SPEED_15_KMH Please see attachment, Conclusion: EPB System CCB - JAS - 11.08.21:Please investigate this point and advise the next steps.12/02/21: Change Implemented per associated task., LogType: Other
LogType: Other, Company: CustomerDevelopment, Summary: [Issue] of PBC_040 - SIL Test - RAR perform with speed >= 15 km/h
Provide the details for the given input
ID: 5532795, Summary: [Issue] of PBC_040 - SIL Test - PowerLatchRequest = ePbcPowerLatchNotRequested too early, State: ALM_Rejected, Project: /EPB/CustomerDevelopment/Ford/P708-eDIH-Livonia, Company: CustomerDevelopment, Team: , Classification: Incident / Problem / Bug, Comments: , Description: Preconditions: Init with Fully released actuators.Action:Apply Release under several condition.Expected Behaviour: PbcOut.EcuPowerLatchRequest = ePbcPowerLatchNotRequested two cycles after last PbcOut.MotorComamd = ePbcMotorCommandNoneActual behaviour: PbcOut.EcuPowerLatchRequest = ePbcPowerLatchNotRequested after last Pbcout.Actuatorstae = ePbcActuatorStateParkApplied ORePbcActuatorStateReleasedFurther Information/Requirements: This can lead to a lock of software. In the past we made the experience that the Host system calls PBC.Cyclic as long as PbcOut.EcuPowerLatchRequest = ePbcPowerLatchRequested and if this signal depends on the actuatorstate it can happen that the PbcMotoCommands stays at ePbcMotorCommandStop.Please see attachment, Conclusion: EPB System CCB - JAS - 11.08.21:Please investigate this point and advise the next steps.11/9/21: mrb Per Design Board review, this requirement is NOT necessary. (ML), LogType: Other
ID: 5532795
Provide the details for the given ID
ID: 5532795, Summary: [Issue] of PBC_040 - SIL Test - PowerLatchRequest = ePbcPowerLatchNotRequested too early, State: ALM_Rejected, Project: /EPB/CustomerDevelopment/Ford/P708-eDIH-Livonia, Company: CustomerDevelopment, Team: , Classification: Incident / Problem / Bug, Comments: , Description: Preconditions: Init with Fully released actuators.Action:Apply Release under several condition.Expected Behaviour: PbcOut.EcuPowerLatchRequest = ePbcPowerLatchNotRequested two cycles after last PbcOut.MotorComamd = ePbcMotorCommandNoneActual behaviour: PbcOut.EcuPowerLatchRequest = ePbcPowerLatchNotRequested after last Pbcout.Actuatorstae = ePbcActuatorStateParkApplied ORePbcActuatorStateReleasedFurther Information/Requirements: This can lead to a lock of software. In the past we made the experience that the Host system calls PBC.Cyclic as long as PbcOut.EcuPowerLatchRequest = ePbcPowerLatchRequested and if this signal depends on the actuatorstate it can happen that the PbcMotoCommands stays at ePbcMotorCommandStop.Please see attachment, Conclusion: EPB System CCB - JAS - 11.08.21:Please investigate this point and advise the next steps.11/9/21: mrb Per Design Board review, this requirement is NOT necessary. (ML), LogType: Other
Summary: [Issue] of PBC_040 - SIL Test - PowerLatchRequest = ePbcPowerLatchNotRequested too early
Provide the details for the given Summary
ID: 5532795, Summary: [Issue] of PBC_040 - SIL Test - PowerLatchRequest = ePbcPowerLatchNotRequested too early, State: ALM_Rejected, Project: /EPB/CustomerDevelopment/Ford/P708-eDIH-Livonia, Company: CustomerDevelopment, Team: , Classification: Incident / Problem / Bug, Comments: , Description: Preconditions: Init with Fully released actuators.Action:Apply Release under several condition.Expected Behaviour: PbcOut.EcuPowerLatchRequest = ePbcPowerLatchNotRequested two cycles after last PbcOut.MotorComamd = ePbcMotorCommandNoneActual behaviour: PbcOut.EcuPowerLatchRequest = ePbcPowerLatchNotRequested after last Pbcout.Actuatorstae = ePbcActuatorStateParkApplied ORePbcActuatorStateReleasedFurther Information/Requirements: This can lead to a lock of software. In the past we made the experience that the Host system calls PBC.Cyclic as long as PbcOut.EcuPowerLatchRequest = ePbcPowerLatchRequested and if this signal depends on the actuatorstate it can happen that the PbcMotoCommands stays at ePbcMotorCommandStop.Please see attachment, Conclusion: EPB System CCB - JAS - 11.08.21:Please investigate this point and advise the next steps.11/9/21: mrb Per Design Board review, this requirement is NOT necessary. (ML), LogType: Other
LogType: Other, Company: CustomerDevelopment, Summary: [Issue] of PBC_040 - SIL Test - PowerLatchRequest = ePbcPowerLatchNotRequested too early
Provide the details for the given input
ID: 5533018, Summary: [Daimler_MMA_IBC] VX1000 connection setting in A2l shall be corrected, State: ALM_Rejected, Project: /BRK/Customer/Daimler/MMA/IBC, Company: Daimler, Team: 4488194, Classification: Incident / Problem / Bug, Comments: [rausch fabian kbl adws31 (rauschf), aug 30, 2021 7:18:38 am cest]as confirmed in the attached email the issue is solved. cr was moved to rejected. [scafes alexandru tms (z0022277), aug 27, 2021 11:52:52 am cest]integration & build, a scafes 27.08.21 it have been confirmed that the issue was solved. see the email attachment. i propose the cr for rejection.[andre andreas kbl adws32 (andrea), aug 27, 2021 8:42:20 am cest]brksw integration & services ccb - aa (27.08.21 - 08:41):reinvestigate this cr according new information., Description: When trying o connect CANApe with generatedDA31_P05_M10_S02_VT2_200_010_000_RTP.A2L, following error is occured. Please analys and implment necessary Changes in A2l, Conclusion: [26.08.2021, ScafesA]Brief analysis summary:The issue appear for the A2L generated in the SW version X200. In the X200 it was a issue and the information in the A2Ls have been incomplete and wrong and could cause errors with the VX1000 connection.That Issue is confirmed that have been solved starting with SW version X250 with CR 5528764.Risk (low/medium/high): mediumAnalysis completed by (applicable only for distributed analyses):Alexandru ScafesProposal of next steps (incl. effort/h and verification): Retest if the VX 1000 connection is corrected and if the errors is still present on SW version X250 or newer., LogType: Other
ID: 5533018
Provide the details for the given ID
ID: 5533018, Summary: [Daimler_MMA_IBC] VX1000 connection setting in A2l shall be corrected, State: ALM_Rejected, Project: /BRK/Customer/Daimler/MMA/IBC, Company: Daimler, Team: 4488194, Classification: Incident / Problem / Bug, Comments: [rausch fabian kbl adws31 (rauschf), aug 30, 2021 7:18:38 am cest]as confirmed in the attached email the issue is solved. cr was moved to rejected. [scafes alexandru tms (z0022277), aug 27, 2021 11:52:52 am cest]integration & build, a scafes 27.08.21 it have been confirmed that the issue was solved. see the email attachment. i propose the cr for rejection.[andre andreas kbl adws32 (andrea), aug 27, 2021 8:42:20 am cest]brksw integration & services ccb - aa (27.08.21 - 08:41):reinvestigate this cr according new information., Description: When trying o connect CANApe with generatedDA31_P05_M10_S02_VT2_200_010_000_RTP.A2L, following error is occured. Please analys and implment necessary Changes in A2l, Conclusion: [26.08.2021, ScafesA]Brief analysis summary:The issue appear for the A2L generated in the SW version X200. In the X200 it was a issue and the information in the A2Ls have been incomplete and wrong and could cause errors with the VX1000 connection.That Issue is confirmed that have been solved starting with SW version X250 with CR 5528764.Risk (low/medium/high): mediumAnalysis completed by (applicable only for distributed analyses):Alexandru ScafesProposal of next steps (incl. effort/h and verification): Retest if the VX 1000 connection is corrected and if the errors is still present on SW version X250 or newer., LogType: Other
Summary: [Daimler_MMA_IBC] VX1000 connection setting in A2l shall be corrected
Provide the details for the given Summary
ID: 5533018, Summary: [Daimler_MMA_IBC] VX1000 connection setting in A2l shall be corrected, State: ALM_Rejected, Project: /BRK/Customer/Daimler/MMA/IBC, Company: Daimler, Team: 4488194, Classification: Incident / Problem / Bug, Comments: [rausch fabian kbl adws31 (rauschf), aug 30, 2021 7:18:38 am cest]as confirmed in the attached email the issue is solved. cr was moved to rejected. [scafes alexandru tms (z0022277), aug 27, 2021 11:52:52 am cest]integration & build, a scafes 27.08.21 it have been confirmed that the issue was solved. see the email attachment. i propose the cr for rejection.[andre andreas kbl adws32 (andrea), aug 27, 2021 8:42:20 am cest]brksw integration & services ccb - aa (27.08.21 - 08:41):reinvestigate this cr according new information., Description: When trying o connect CANApe with generatedDA31_P05_M10_S02_VT2_200_010_000_RTP.A2L, following error is occured. Please analys and implment necessary Changes in A2l, Conclusion: [26.08.2021, ScafesA]Brief analysis summary:The issue appear for the A2L generated in the SW version X200. In the X200 it was a issue and the information in the A2Ls have been incomplete and wrong and could cause errors with the VX1000 connection.That Issue is confirmed that have been solved starting with SW version X250 with CR 5528764.Risk (low/medium/high): mediumAnalysis completed by (applicable only for distributed analyses):Alexandru ScafesProposal of next steps (incl. effort/h and verification): Retest if the VX 1000 connection is corrected and if the errors is still present on SW version X250 or newer., LogType: Other
LogType: Other, Company: Daimler, Summary: [Daimler_MMA_IBC] VX1000 connection setting in A2l shall be corrected
Provide the details for the given input
ID: 5533022, Summary: [VW KPM] [SV][BL][CAN] F1AB nach CheckMemory, State: ALM_Closed, Project: /BRK/Customer/VW/MQB48-W/ESC, Company: VW, Team: 2504600, Classification: Incident / Problem / Bug, Comments: [(system user) user for queue manager (scs_queuemanager), sep 16, 2021 3:35:27 pm cest]preintegration of 5655446 was successful. a checkpoint has been created on path #/brk#customer/vw/mqb48-w/esc/05_software/view_mainline/mmc_boot#d=preinteg_vw_mqb_esc_a. checkpoint number is 1.13.1.1.1.13., Description: [Error Description]: VW80126.Gutfall (80126/VW80126.Gutfall):FLASH_TEST_GutfallKommentar Prüfer:Es hat sich trotz CheckMemory keiner der Software Block Versionen aktualisiert.[A: 80126-A119][A: 80126-A694]Fehler-Beschreibung DANTE:00000 (DIAG): Diagnose - RequestPDU (3): 22 F1 ABResponse (39): 62 F1 AB 58 33 32 35 58 33 32 33 41 30 30 32 44 45 4D 4F 49 58 30 35 41 30 30 36 41 30 30 31 42 30 30 31 42 30 30 3100000 (TEST): Block 1 Typ: Writable [DATA]. Die Software Block Version hat sich vor dem CheckMemory aktualisiert. > n.i.O.00000 (TEST): Typ: Writable [DATA]. Es hat sich trotz CheckMemory keiner der Software Block Versionen aktualisiert oder es wurde bereits vor dem CheckMemory gemacht. > n.i.O.zugehörige Dateien:Gutfall_2021-06-21_15-16-27_CAN_Diagnose.asc[Fault Type]: 0[Creator Contact Person]: Koch, Sven[Creator Email]: extern.nils.krueger@volkswagen.de[Creator Phone]: Developer comment: In SW Module apnv.c - ApplFblNvWriteBlockStates the invalidation of the block is not taking place. Needs to be corrected., Conclusion: Title: [VW KPM] [SV][BL][CAN] F1AB nach CheckMemory - Block Invalidation not ImplementedDescription:· Add NVRAM Block state write to invalidation of logical block Proposed Tests:· Check if block is invalid after erasing Estimated design effort/h: 1 Estimated implementation effort/h: 1 Estimated unit testing effort/h: 1 Total effort/h: 3 [Optional] Planned completion date:, LogType: Memory
ID: 5533022
Provide the details for the given ID
ID: 5533022, Summary: [VW KPM] [SV][BL][CAN] F1AB nach CheckMemory, State: ALM_Closed, Project: /BRK/Customer/VW/MQB48-W/ESC, Company: VW, Team: 2504600, Classification: Incident / Problem / Bug, Comments: [(system user) user for queue manager (scs_queuemanager), sep 16, 2021 3:35:27 pm cest]preintegration of 5655446 was successful. a checkpoint has been created on path #/brk#customer/vw/mqb48-w/esc/05_software/view_mainline/mmc_boot#d=preinteg_vw_mqb_esc_a. checkpoint number is 1.13.1.1.1.13., Description: [Error Description]: VW80126.Gutfall (80126/VW80126.Gutfall):FLASH_TEST_GutfallKommentar Prüfer:Es hat sich trotz CheckMemory keiner der Software Block Versionen aktualisiert.[A: 80126-A119][A: 80126-A694]Fehler-Beschreibung DANTE:00000 (DIAG): Diagnose - RequestPDU (3): 22 F1 ABResponse (39): 62 F1 AB 58 33 32 35 58 33 32 33 41 30 30 32 44 45 4D 4F 49 58 30 35 41 30 30 36 41 30 30 31 42 30 30 31 42 30 30 3100000 (TEST): Block 1 Typ: Writable [DATA]. Die Software Block Version hat sich vor dem CheckMemory aktualisiert. > n.i.O.00000 (TEST): Typ: Writable [DATA]. Es hat sich trotz CheckMemory keiner der Software Block Versionen aktualisiert oder es wurde bereits vor dem CheckMemory gemacht. > n.i.O.zugehörige Dateien:Gutfall_2021-06-21_15-16-27_CAN_Diagnose.asc[Fault Type]: 0[Creator Contact Person]: Koch, Sven[Creator Email]: extern.nils.krueger@volkswagen.de[Creator Phone]: Developer comment: In SW Module apnv.c - ApplFblNvWriteBlockStates the invalidation of the block is not taking place. Needs to be corrected., Conclusion: Title: [VW KPM] [SV][BL][CAN] F1AB nach CheckMemory - Block Invalidation not ImplementedDescription:· Add NVRAM Block state write to invalidation of logical block Proposed Tests:· Check if block is invalid after erasing Estimated design effort/h: 1 Estimated implementation effort/h: 1 Estimated unit testing effort/h: 1 Total effort/h: 3 [Optional] Planned completion date:, LogType: Memory
Summary: [VW KPM] [SV][BL][CAN] F1AB nach CheckMemory
Provide the details for the given Summary
ID: 5533022, Summary: [VW KPM] [SV][BL][CAN] F1AB nach CheckMemory, State: ALM_Closed, Project: /BRK/Customer/VW/MQB48-W/ESC, Company: VW, Team: 2504600, Classification: Incident / Problem / Bug, Comments: [(system user) user for queue manager (scs_queuemanager), sep 16, 2021 3:35:27 pm cest]preintegration of 5655446 was successful. a checkpoint has been created on path #/brk#customer/vw/mqb48-w/esc/05_software/view_mainline/mmc_boot#d=preinteg_vw_mqb_esc_a. checkpoint number is 1.13.1.1.1.13., Description: [Error Description]: VW80126.Gutfall (80126/VW80126.Gutfall):FLASH_TEST_GutfallKommentar Prüfer:Es hat sich trotz CheckMemory keiner der Software Block Versionen aktualisiert.[A: 80126-A119][A: 80126-A694]Fehler-Beschreibung DANTE:00000 (DIAG): Diagnose - RequestPDU (3): 22 F1 ABResponse (39): 62 F1 AB 58 33 32 35 58 33 32 33 41 30 30 32 44 45 4D 4F 49 58 30 35 41 30 30 36 41 30 30 31 42 30 30 31 42 30 30 3100000 (TEST): Block 1 Typ: Writable [DATA]. Die Software Block Version hat sich vor dem CheckMemory aktualisiert. > n.i.O.00000 (TEST): Typ: Writable [DATA]. Es hat sich trotz CheckMemory keiner der Software Block Versionen aktualisiert oder es wurde bereits vor dem CheckMemory gemacht. > n.i.O.zugehörige Dateien:Gutfall_2021-06-21_15-16-27_CAN_Diagnose.asc[Fault Type]: 0[Creator Contact Person]: Koch, Sven[Creator Email]: extern.nils.krueger@volkswagen.de[Creator Phone]: Developer comment: In SW Module apnv.c - ApplFblNvWriteBlockStates the invalidation of the block is not taking place. Needs to be corrected., Conclusion: Title: [VW KPM] [SV][BL][CAN] F1AB nach CheckMemory - Block Invalidation not ImplementedDescription:· Add NVRAM Block state write to invalidation of logical block Proposed Tests:· Check if block is invalid after erasing Estimated design effort/h: 1 Estimated implementation effort/h: 1 Estimated unit testing effort/h: 1 Total effort/h: 3 [Optional] Planned completion date:, LogType: Memory
LogType: Memory, Company: VW, Summary: [VW KPM] [SV][BL][CAN] F1AB nach CheckMemory
Provide the details for the given input
ID: 5533019, Summary: [VW KPM] [SV][PMode][CAN] PMode Parameter FF FF FF, State: ALM_Closed, Project: /BRK/Customer/VW/MQB48-W/ESC, Company: VW, Team: 2504591, Classification: Incident / Problem / Bug, Comments: , Description: Perform an analysis for the issue below and suggest the next steps. [Error Description]: Kontaktdaten:E-Mail: VWAG R: WOB, EESN Sys-VQBeanstandung vom Sys-VQ-PrüfplatzPMode.00.01.0.040.010 (PMode/PMode_ab_V8.1/physikalisch):Aktivierung aller Produktionsmodes in erlaubter SessionKommentar Prüfer:Der P-Mode wird durch die Parameter 0xFF FF FF nicht aktiviert. Gemäß der Spezifikation muss der P-Mode aktiviert werden, da mit Parameter 0xFF FF FF alle Bits gesetzt sind.[A: Q-LAH_PMode-9]Fehler-Beschreibung DANTE:00000 (DIAG): Diagnose - RequestPDU (3): 22 04 FEResponse (6): 62 04 FE 00 00 0000000 (TEST): Der Identifier 04 FE wurde mit 0x62 04 FE 00 00 00 beantwortet.Erwartet: != 00 00 00. > n.i.O.zugehörige Dateien:TC_PMode_00_01_0_040_010_2021-06-21_15-04-28_CAN_Diagnose.asc[Fault Type]: 0[Creator Contact Person]: Koch, Sven[Creator Email]: extern.nils.krueger@volkswagen.de[Creator Phone]:, Conclusion: 05.08.2021 BoianD: This topic is related to Base Software (Diag / Chasinf). OBD / SiSo has nothing to do with the triggering of the production mode., LogType: Other
ID: 5533019
Provide the details for the given ID
ID: 5533019, Summary: [VW KPM] [SV][PMode][CAN] PMode Parameter FF FF FF, State: ALM_Closed, Project: /BRK/Customer/VW/MQB48-W/ESC, Company: VW, Team: 2504591, Classification: Incident / Problem / Bug, Comments: , Description: Perform an analysis for the issue below and suggest the next steps. [Error Description]: Kontaktdaten:E-Mail: VWAG R: WOB, EESN Sys-VQBeanstandung vom Sys-VQ-PrüfplatzPMode.00.01.0.040.010 (PMode/PMode_ab_V8.1/physikalisch):Aktivierung aller Produktionsmodes in erlaubter SessionKommentar Prüfer:Der P-Mode wird durch die Parameter 0xFF FF FF nicht aktiviert. Gemäß der Spezifikation muss der P-Mode aktiviert werden, da mit Parameter 0xFF FF FF alle Bits gesetzt sind.[A: Q-LAH_PMode-9]Fehler-Beschreibung DANTE:00000 (DIAG): Diagnose - RequestPDU (3): 22 04 FEResponse (6): 62 04 FE 00 00 0000000 (TEST): Der Identifier 04 FE wurde mit 0x62 04 FE 00 00 00 beantwortet.Erwartet: != 00 00 00. > n.i.O.zugehörige Dateien:TC_PMode_00_01_0_040_010_2021-06-21_15-04-28_CAN_Diagnose.asc[Fault Type]: 0[Creator Contact Person]: Koch, Sven[Creator Email]: extern.nils.krueger@volkswagen.de[Creator Phone]:, Conclusion: 05.08.2021 BoianD: This topic is related to Base Software (Diag / Chasinf). OBD / SiSo has nothing to do with the triggering of the production mode., LogType: Other
Summary: [VW KPM] [SV][PMode][CAN] PMode Parameter FF FF FF
Provide the details for the given Summary
ID: 5533019, Summary: [VW KPM] [SV][PMode][CAN] PMode Parameter FF FF FF, State: ALM_Closed, Project: /BRK/Customer/VW/MQB48-W/ESC, Company: VW, Team: 2504591, Classification: Incident / Problem / Bug, Comments: , Description: Perform an analysis for the issue below and suggest the next steps. [Error Description]: Kontaktdaten:E-Mail: VWAG R: WOB, EESN Sys-VQBeanstandung vom Sys-VQ-PrüfplatzPMode.00.01.0.040.010 (PMode/PMode_ab_V8.1/physikalisch):Aktivierung aller Produktionsmodes in erlaubter SessionKommentar Prüfer:Der P-Mode wird durch die Parameter 0xFF FF FF nicht aktiviert. Gemäß der Spezifikation muss der P-Mode aktiviert werden, da mit Parameter 0xFF FF FF alle Bits gesetzt sind.[A: Q-LAH_PMode-9]Fehler-Beschreibung DANTE:00000 (DIAG): Diagnose - RequestPDU (3): 22 04 FEResponse (6): 62 04 FE 00 00 0000000 (TEST): Der Identifier 04 FE wurde mit 0x62 04 FE 00 00 00 beantwortet.Erwartet: != 00 00 00. > n.i.O.zugehörige Dateien:TC_PMode_00_01_0_040_010_2021-06-21_15-04-28_CAN_Diagnose.asc[Fault Type]: 0[Creator Contact Person]: Koch, Sven[Creator Email]: extern.nils.krueger@volkswagen.de[Creator Phone]:, Conclusion: 05.08.2021 BoianD: This topic is related to Base Software (Diag / Chasinf). OBD / SiSo has nothing to do with the triggering of the production mode., LogType: Other
LogType: Other, Company: VW, Summary: [VW KPM] [SV][PMode][CAN] PMode Parameter FF FF FF
Provide the details for the given input
ID: 5533079, Summary: [Defect]: [Diag] ESP178: Session Handling-OTX - Check reprogramming precondition Not Implemented, State: ALM_Closed, Project: /BRK/Customer/Daimler/MMA/IBC, Company: Daimler, Team: 4488191, Classification: Incident / Problem / Bug, Comments: [christian weyand (weyandc), jun 2, 2021 11:40:40 am cest]ccb-dc, weyandc: cr is closed after review.- [autosar] changes have been checked in with task 5292076. the task is linked to cr 5290840 which is linked to the same build as this cr.- [diag] related gaps regarding swe2, swe3 and swe4 will be handled with spawned cr 5323111.- [swad] task was canceled. the requested action will be performed with spawned cr 5346776 for sw_ad_backlog_x0200 with id 5323597.[christian rauh (rauhc), may 20, 2021 2:54:46 pm cest]dc-ccb: cr set to planned.[christian rauh (rauhc), may 20, 2021 2:54:24 pm cest]dc-ccb: cr approved.[christian rauh (rauhc), apr 14, 2021 3:28:49 pm cest]dc-ccb: please analyse and propose next steps., Description: This CR shall be used to implement the following diagnostic jobs:1. Check Reprogramming Preconditions - StartRoutine: $31 01 02 03 zz2. PreCheckProgrammingDependencies - StartRoutine: $31 01 02 07 zz Information:- The behavior of the routines is specified in the CDD but it must be checked whether further relevant customer requirements are specified in other specifications + DOORS modules.- The CR shall cover SWE1, SWE2, SWE3 and SWE4.- The CR has not be derived from BROP and/or DCRP but has been requested by the customer to be implemented for B1.1 (= X0150). Please, refer to the attached Excel Sheet "MMA_Diag_EffortEstimation_basedOn_v2.5_PlanningStatus_2021-04-08.xlsx" that is exchanged with the customer. To Diag CCB:- Please, add owner from Diag team.- Please, add analysers from Diag team and SwAD team., Conclusion: Brief analysis summary:19.05.2021 WeyandC:Routine 0x0203 "Check Reprogramming Preconditions" is not specified in DOORS module "EBS_Diagnostic_Requirements_Specification". But the routines is specified by the CDD and by specification "DDS R01-01".It is no longer requested by the customer that routine 0x0207 "PreCheckProgrammingDependencies" is supported by the application. This is why follow-up ALM_Change Request 5198683 has been or will be rejected.Purpose of the CR: 1. Implement sub function $01 "StartRoutine" for routine 0x0203 "Check Reprogramming Preconditions":The routine shall check which conditions are currently not fulfilled for entering the programming session. It shall return the number of not fulfilled conditions and a list of those conditions.The CDD already specifies a list of unfulfilled conditions. Additional conditions might be added if required after consultation with the customer.The following reasons have been identified and have been discussed with the customer: - 0x05: vehicle speed - 0x06: (1) Control is active or (2) EPB actuation is ongoing=> Please, note that condition (2) for reason 0x06 has not been specified by customer or System but it is expected that the condition will be specified by System in the future.Therefore, the check will be considered for the implementation of this routine. However, the stub ("IsEcuResetAllowedByPb") for the actual condition check will be kept as for the "Entering Programming Session" job ($10 02).2. As this is the first routine that is implemented for MMA, the CR must also be used to adapt the Diag framework to support routines under the project-specific conditions.- Adaptations are required to support sub function $01 "StartRoutine" for service $31 "RoutineControl" with additional response bytes.- Therefore, the generic start routine handling shall be adapted.- The following SW pool components are affected: DiagArAdapter, DiagTestMgmtUnitDIAG part: 1. Adapt SWC Diag- Add service port for the new routine to SWC Diag and configure direction to server:- Add runnable for the new routine.=> Export updated Diag_AUTOSAR_Diag.arxml.2. implementation of routine 0x0203 "Check Reprogramming Preconditions":=> Please, refer to the task description of the [SWE3/4][Diag] task for details: ALM_Task 53004693. Diag framework adaptations:=> Please, refer to the task description of the [SWE3/4][Diag] task for details: ALM_Task 5300469AUOTSAR part: - Import updated Diag_AUTOSAR_Diag.arxml.- Connect Dcm port to SWC Diag port for the new routine 0x0203 "Check Reprogramming Preconditions"- Map the new runnable to OS task Task_DiagEvents_D_C0_1. The slot is not relevant.=> Generate RTE and OS.NOTE: 1. SWC-Diag will call the following Autosar interfaces: - (void)Rte_Read_R_BrakeActive_BrakeControlArbitratorActive(&brake_ctrl_active); - (void)Rte_Read_R_ArbDriveTorque_DriveControlArbitratorActive(&drive_ctrl_active);The ports are still connected from Geely / VW (= baseline for the MMA project). No actions are required.The Autosar interfaces can be used from SwAD / Autosar point of view. Please, refer to the attached email "AW_ ALM_Change Request 5136349_ _MMA_Ő_Diag_ Implement _Programming Check_ routines.msg" for details.2. Diag Design:- It was decided for this routine that Dcm configuration is not manually adapted in DaVinci Configurator. The multiple in and out parameters are NOT replaced with a single in- and a single out-parameter. Hence, the DiagArAdapter routine runnable must copy data from the multiple in-parameters to the single generic Diag in-parameter and vice versa from the single Diag generic out-parameter to the multiple out-parameters.- It was also decided that stack variables (= function variables) will be used as the additional stack consumption is negligible.- For the future, it will be check whether the Dcm configuration will be manually adapted in DaVinci Configurator for new routines or whether shared Diag RAM variables shall be used to copy data between parameters defined by Autosar and generic Diag parameters.=> Both decision will not affect the implementation of routine 0x0203 that is provided with this CR.Risk (low/medium/high):mediumAnalysis completed by (applicable only for distributed analyses): WeyandC, SwAD part confirmed by C. Klukowski, Autosar task proposal confirmed by S. Basavaraju via TeamsProposal of next steps (incl. effort/h and verification):TASK 1/5Title: [MMA][Autosar][X0200] Connect ports between Dcm and SWC DIAG and map ports to OS tasks for routine 0x0203Description:- Import updated Diag_AUTOSAR_Diag.arxml.- Connect Dcm port to SWC Diag port for the new routine: 0x0203 "Check Reprogramming Preconditions"- Map the new runnable for the routine to OS task Task_DiagEvents_D_C0_1. The slot is not relevant.=> Generate RTE, and OS.Owner: Hemanth AmbarukhanaReviewer: Sireesha Basavaraju, C. WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 7h[Optional] Planned completion date: 26.05.2021 (set by task owner)TASK 2/5Title: [MMA][Diag][SWE1][X0200] Support new routine 0x0203 "Check Reprogramming Preconditions"Description:The following DIDs routine be implemented with this CR: Routine 0x0203 "Check Reprogramming Preconditions" with sub function $01 "StartRoutine" is specified by the CDD and by specification "DDS R01-01". Functionality:The routine shall check which conditions are currently not fulfilled for entering the programming session. It shall return the number of not fulfilled conditions and a list of those conditions.The CDD already specifies a list of unfulfilled conditions. Additional conditions might be added if required after consultation with the customer.The following reasons have been identified by now or require clarification:- 0x05: vehicle speed- 0x06: (1) Control is active or (2) EPB actuation is ongoing=> Please, note that condition (2) for reason 0x06 has not been specified by customer or System but it is expected that the condition will be specified by System in the future. Therefore, the check will be considered for the implementation of this routine. However, the stub ("IsEcuResetAllowedByPb") for the actual condition check will be kept as for the "Entering Programming Session" job ($10 02). Refer to the attached emails for further details. Please, use this CR to define SW requirements for this routine.Owner: J. HornungReviewer: C. WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 4h[Optional] Planned completion date: 26.05.2021TASK 3/5Title: [MMA][Diag][SWE2][X0200] Support new routine 0x0203 "Check Reprogramming Preconditions"Description:(SWE2) Please update SwAD model according to derived requirements. The CR is used to implement routine 0x0203 "Check Reprogramming Preconditions".Please, note that SW requirements might not be available in time. In that case, it must be checked whether a follow-up CR needs to be created.Owner: C. WeyandReviewer: A. ElfekyEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 4h[Optional] Planned completion date: 28.05.2021TASK 4/5Title: [MMA][Diag][SWE3/4][X0200] Implement routine 0x0203 "Check Reprogramming Preconditions" and adapt RoutineControl frameworkDescription:Purpose of the task:1. Implement sub function $01 "StartRoutine" for routine 0x0203 "Check Reprogramming Preconditions":The routine shall check which conditions are currently not fulfilled for entering the programming session. It shall return the number of not fulfilled conditions and a list of those conditions.The CDD already specifies a list of unfulfilled conditions. Additional conditions might be added if required after consultation with the customer.The following reasons have been identified by now or require clarification:- 0x05: vehicle speed- 0x06: (1) Control is active or (2) EPB actuation is ongoing=> Please, note that condition (2) for reason 0x06 has not been specified by customer or System but it is expected that the condition will be specified by System in the future.Therefore, the check will be considered for the implementation of this routine. However, the stub ("IsEcuResetAllowedByPb") for the actual condition check will be kept as for the "Entering Programming Session" job ($10 02).2. As this is the first routine that is implemented for MMA, the task must also be used to adapt the Diag framework to support routines under the project-specific conditions.- Adaptations are required to support sub function $01 "StartRoutine" for service $31 "RoutineControl" with additional response bytes.- Therefore, the generic start routine handling shall be adapted.- The following SW pool components are affected: DiagArAdapter, DiagTestMgmtUnitGeneral:This task shall be used for SWE3 (design model update + implementation) + SWE4 (VCast).Details:1. Adapt SWC Diag:- Add service port for the new routine to SWC Diag and configure direction to server:- Add runnable for the new routine.=> Export updated Diag_AUTOSAR_Diag.arxml2. Framework adaptations:DiagArAdapter:- Adapt the interface GenericStartRoutineInterface:- new parameter list: const U16 test_id, const U8 *input_parameters, U8 *const output_parameters, const U8 param_length, U16 * const out_param_length, Dcm_NegativeResponseCodeType *ErrorCode- adapt the call of function CommandTest according to the new parameter list of the CommandInterface- Adapt the interface GenericStopRoutineInterface- adapt the call of function CommandTest according to the new parameter list of the CommandInterface- Adapt the interface GenericASyncShortTermAdjustmentInterface- adapt the call of function CommandTest according to the new parameter list of the CommandInterfaceTestGroup:- Adapt the interface CommandTest:- new parameter list: const U16 comms_id, const U8 test_type, const BOOLEAN command, const U8* const parameters, U8* const output_data, const U16 length, U16* const out_length- add a new block after the "Execute Command" block and before the "Update Group Status block":- check if "status" is TST_STATUS_OK and "out_length" is not NULL; if so call interface "ExecuteGetCommandDataInterface" and store the return value via "out_length" pointer- Add new type definition in the global header file for function pointer to retrieve the response parameters for start routine service request: typedef U16 (*GET_COMMAND_TEST_DATA_TYPE)(U8* results)TestSpecification:- Add new function U16 ExecuteGetCommandDataInterface(const U32 test_id, U8 results_buffer[]) with subsystem scope- the function shall check whether "GetCommandTestDataInterface" is not NULL for the given "test_id"- if so, it shall return the length returned by the respective "GetCommandTestDataInterface" interface.- otherwise, it shall return 0 as length.- Adapt definition of data type TEST_SPEC_DATA_TYPE:- add new paramter "GET_COMMAND_TEST_DATA_TYPE GetCommandTestDataInterface" behind the "Get_Result_Data_Inteface" parameterInputOutputControlById.c:- non functional adaptation to make the SW compile:- adapt the calls of function "CommandTest" in function "IoControlByIdentifier" to make the SW compile- pass NULL for the new parameters of "CommandTest"3. Implementation of routine 0x0203:DiagArAdapter_cfg:- Implement the new runnable "RoutineServices_Check_Reprogramming_Preconditions_Start":- define stack variables:- for 2nd parameter of CommandTest: const U8 start_routine_in_signals = 0u- for 3rd parameter of CommandTest (=> it is expected that a size of 8 bytes will be sufficient => currently a size of 2 bytes would be ok): U8 start_routine_out_signals[DIAG_PRGR_PRECND_MAX_DYN_LENGTH]- for 5th parameter of CommandTest: U16 data_length_out = 0u- OpStatus == DCM_initial:- call CommandTest with the listed parameters and with 1st parameter = PROG_PRECOND_CHECK_TEST_ID, with 4th parameter = 0 and with ErrorCode as 6th parameter- if returned data_length_out is less than minimal response length (= 2) or greater than minimal response legnth + size of array "start_routine_out_signals":- call UpdateTestManagementActive(FALSE)- return E_NOT_OK with ErrorCode DCM_E_GENERALREJECT- otherwise:- copy data from "start_routine_out_signals" to actual out parameters "routineInfo_Out", "Number_of_Unfulfilled_Preconditions_Out", "List_of_Preconditions_Out" and set "DataLength" to the correct value- return E_OK- OpStatus == DCM_CANCEL:- call UpdateTestManagementActive(FALSE)- return E_OK- OpStatus has another value:- return E_NOT_OK with ErrorCode DCM_E_GENERALREJECTTestSpecification_Cfg:- Adapt ROM table Test_Spec_Data: replace dummy entry with entry for routine 0x0203:{&CommandChkPrgrPrecnd,&UpdateChkPrgrPrecnd,NULL,NULL,&ReportChkPrgrPrecndCommandData,PROG_PRECOND_CHECK_TEST_ID,ROUTINE_BY_ID_TEST,EXCLUSIVE_TEST_GROUP,SECURITY_ACCESS_NOT_REQUIRED,PARAM_LENGTH_ZERO,(U8)IOC_NO_CHECK_REQUIRED}RoutineControl_Cfg:1. Implement Command_Interface with subsystem scope: CommandChkPrgrPrecnd- Check all programming preconditions by calling the following functions and store the check results in LOCAL variable:- CheckNonDefaultSessionSpeed()=> returns FALSE if speed is to high and programming session cannot be entered- (void)Rte_Read_R_BrakeActive_BrakeControlArbitratorActive(&BOOLEAN x) and (void)Rte_Read_R_ArbDriveTorque_DriveControlArbitratorActive(&BOOLEAN y)=> at least one function returns TRUE if a control intervention is active and programming session cannot be entered- IsEcuResetAllowedByPb()=> returns FALSE if EPB actuation is active and programming session cannot be entered2. Implement Update_Interface with subsystem scope: UpdateChkPrgrPrecnd- just return FALSE3. Implement GetCommandTestDataInterface with subsystem scope: ReportChkPrgrPrecndCommandData- set first response byte (DIAG_ROUTINE_STATUS_BYTE_INDEX) to 0x00 (DIAG_DAI_RID_SUCCESS_COMPLETED)- set second byte to the number of Programming PreConditions that are not fulfilled and prevent the system from entering the programming session => note: the number must be calculated in this function- if speed condition is unfulfilled, set next free response byte to 0x05 (DIAG_VEHICLE_SPEED_COND)- if control intervention or EPB actuation is in progress, set next free response byte to 0x06 (DIAG_CONTROLLER_ACTIVE_COND)- return the number of additional response bytes (= all bytes without pos. response byte + subfunction byte and RID bytes)Note:Please, find an untested(!) implementation proposal "Untested_Diag_ImplementatioProposal.zipx" attached to the task.Note that this implementation might not work correctly, and may cause QAC and polyspace warnings that needs to be fixed or handled.The proposal is based on SW checkpoint 1.3.3.142 with DiagArAdapter checkpoint 1.9.1.16 and DiagTestMgmtUnit checkpoint 1.8.2.7.Owner: Ashwini DigajerlaReviewer: C. WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 18h[Optional] Planned completion date: 25.05.2021 (set by task owner)TASK 5/5Title: [MMA][X0200][SWAD] Support new routine 0x0203 "Check Reprogramming Preconditions"Description:Please import and map requirements for stub implementation of the following routine:0x0203 "Check Reprogramming Preconditions" Map new runnable to OS task Task_DiagEvents_D_C0_1.Owner: C. KlukowskiReviewer: C. Bayer, C. WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 8h[Optional] Planned completion date: 27.05.2021 (set by task owner), LogType: Other
ID: 5533079
Provide the details for the given ID
ID: 5533079, Summary: [Defect]: [Diag] ESP178: Session Handling-OTX - Check reprogramming precondition Not Implemented, State: ALM_Closed, Project: /BRK/Customer/Daimler/MMA/IBC, Company: Daimler, Team: 4488191, Classification: Incident / Problem / Bug, Comments: [christian weyand (weyandc), jun 2, 2021 11:40:40 am cest]ccb-dc, weyandc: cr is closed after review.- [autosar] changes have been checked in with task 5292076. the task is linked to cr 5290840 which is linked to the same build as this cr.- [diag] related gaps regarding swe2, swe3 and swe4 will be handled with spawned cr 5323111.- [swad] task was canceled. the requested action will be performed with spawned cr 5346776 for sw_ad_backlog_x0200 with id 5323597.[christian rauh (rauhc), may 20, 2021 2:54:46 pm cest]dc-ccb: cr set to planned.[christian rauh (rauhc), may 20, 2021 2:54:24 pm cest]dc-ccb: cr approved.[christian rauh (rauhc), apr 14, 2021 3:28:49 pm cest]dc-ccb: please analyse and propose next steps., Description: This CR shall be used to implement the following diagnostic jobs:1. Check Reprogramming Preconditions - StartRoutine: $31 01 02 03 zz2. PreCheckProgrammingDependencies - StartRoutine: $31 01 02 07 zz Information:- The behavior of the routines is specified in the CDD but it must be checked whether further relevant customer requirements are specified in other specifications + DOORS modules.- The CR shall cover SWE1, SWE2, SWE3 and SWE4.- The CR has not be derived from BROP and/or DCRP but has been requested by the customer to be implemented for B1.1 (= X0150). Please, refer to the attached Excel Sheet "MMA_Diag_EffortEstimation_basedOn_v2.5_PlanningStatus_2021-04-08.xlsx" that is exchanged with the customer. To Diag CCB:- Please, add owner from Diag team.- Please, add analysers from Diag team and SwAD team., Conclusion: Brief analysis summary:19.05.2021 WeyandC:Routine 0x0203 "Check Reprogramming Preconditions" is not specified in DOORS module "EBS_Diagnostic_Requirements_Specification". But the routines is specified by the CDD and by specification "DDS R01-01".It is no longer requested by the customer that routine 0x0207 "PreCheckProgrammingDependencies" is supported by the application. This is why follow-up ALM_Change Request 5198683 has been or will be rejected.Purpose of the CR: 1. Implement sub function $01 "StartRoutine" for routine 0x0203 "Check Reprogramming Preconditions":The routine shall check which conditions are currently not fulfilled for entering the programming session. It shall return the number of not fulfilled conditions and a list of those conditions.The CDD already specifies a list of unfulfilled conditions. Additional conditions might be added if required after consultation with the customer.The following reasons have been identified and have been discussed with the customer: - 0x05: vehicle speed - 0x06: (1) Control is active or (2) EPB actuation is ongoing=> Please, note that condition (2) for reason 0x06 has not been specified by customer or System but it is expected that the condition will be specified by System in the future.Therefore, the check will be considered for the implementation of this routine. However, the stub ("IsEcuResetAllowedByPb") for the actual condition check will be kept as for the "Entering Programming Session" job ($10 02).2. As this is the first routine that is implemented for MMA, the CR must also be used to adapt the Diag framework to support routines under the project-specific conditions.- Adaptations are required to support sub function $01 "StartRoutine" for service $31 "RoutineControl" with additional response bytes.- Therefore, the generic start routine handling shall be adapted.- The following SW pool components are affected: DiagArAdapter, DiagTestMgmtUnitDIAG part: 1. Adapt SWC Diag- Add service port for the new routine to SWC Diag and configure direction to server:- Add runnable for the new routine.=> Export updated Diag_AUTOSAR_Diag.arxml.2. implementation of routine 0x0203 "Check Reprogramming Preconditions":=> Please, refer to the task description of the [SWE3/4][Diag] task for details: ALM_Task 53004693. Diag framework adaptations:=> Please, refer to the task description of the [SWE3/4][Diag] task for details: ALM_Task 5300469AUOTSAR part: - Import updated Diag_AUTOSAR_Diag.arxml.- Connect Dcm port to SWC Diag port for the new routine 0x0203 "Check Reprogramming Preconditions"- Map the new runnable to OS task Task_DiagEvents_D_C0_1. The slot is not relevant.=> Generate RTE and OS.NOTE: 1. SWC-Diag will call the following Autosar interfaces: - (void)Rte_Read_R_BrakeActive_BrakeControlArbitratorActive(&brake_ctrl_active); - (void)Rte_Read_R_ArbDriveTorque_DriveControlArbitratorActive(&drive_ctrl_active);The ports are still connected from Geely / VW (= baseline for the MMA project). No actions are required.The Autosar interfaces can be used from SwAD / Autosar point of view. Please, refer to the attached email "AW_ ALM_Change Request 5136349_ _MMA_Ő_Diag_ Implement _Programming Check_ routines.msg" for details.2. Diag Design:- It was decided for this routine that Dcm configuration is not manually adapted in DaVinci Configurator. The multiple in and out parameters are NOT replaced with a single in- and a single out-parameter. Hence, the DiagArAdapter routine runnable must copy data from the multiple in-parameters to the single generic Diag in-parameter and vice versa from the single Diag generic out-parameter to the multiple out-parameters.- It was also decided that stack variables (= function variables) will be used as the additional stack consumption is negligible.- For the future, it will be check whether the Dcm configuration will be manually adapted in DaVinci Configurator for new routines or whether shared Diag RAM variables shall be used to copy data between parameters defined by Autosar and generic Diag parameters.=> Both decision will not affect the implementation of routine 0x0203 that is provided with this CR.Risk (low/medium/high):mediumAnalysis completed by (applicable only for distributed analyses): WeyandC, SwAD part confirmed by C. Klukowski, Autosar task proposal confirmed by S. Basavaraju via TeamsProposal of next steps (incl. effort/h and verification):TASK 1/5Title: [MMA][Autosar][X0200] Connect ports between Dcm and SWC DIAG and map ports to OS tasks for routine 0x0203Description:- Import updated Diag_AUTOSAR_Diag.arxml.- Connect Dcm port to SWC Diag port for the new routine: 0x0203 "Check Reprogramming Preconditions"- Map the new runnable for the routine to OS task Task_DiagEvents_D_C0_1. The slot is not relevant.=> Generate RTE, and OS.Owner: Hemanth AmbarukhanaReviewer: Sireesha Basavaraju, C. WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 7h[Optional] Planned completion date: 26.05.2021 (set by task owner)TASK 2/5Title: [MMA][Diag][SWE1][X0200] Support new routine 0x0203 "Check Reprogramming Preconditions"Description:The following DIDs routine be implemented with this CR: Routine 0x0203 "Check Reprogramming Preconditions" with sub function $01 "StartRoutine" is specified by the CDD and by specification "DDS R01-01". Functionality:The routine shall check which conditions are currently not fulfilled for entering the programming session. It shall return the number of not fulfilled conditions and a list of those conditions.The CDD already specifies a list of unfulfilled conditions. Additional conditions might be added if required after consultation with the customer.The following reasons have been identified by now or require clarification:- 0x05: vehicle speed- 0x06: (1) Control is active or (2) EPB actuation is ongoing=> Please, note that condition (2) for reason 0x06 has not been specified by customer or System but it is expected that the condition will be specified by System in the future. Therefore, the check will be considered for the implementation of this routine. However, the stub ("IsEcuResetAllowedByPb") for the actual condition check will be kept as for the "Entering Programming Session" job ($10 02). Refer to the attached emails for further details. Please, use this CR to define SW requirements for this routine.Owner: J. HornungReviewer: C. WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 4h[Optional] Planned completion date: 26.05.2021TASK 3/5Title: [MMA][Diag][SWE2][X0200] Support new routine 0x0203 "Check Reprogramming Preconditions"Description:(SWE2) Please update SwAD model according to derived requirements. The CR is used to implement routine 0x0203 "Check Reprogramming Preconditions".Please, note that SW requirements might not be available in time. In that case, it must be checked whether a follow-up CR needs to be created.Owner: C. WeyandReviewer: A. ElfekyEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 4h[Optional] Planned completion date: 28.05.2021TASK 4/5Title: [MMA][Diag][SWE3/4][X0200] Implement routine 0x0203 "Check Reprogramming Preconditions" and adapt RoutineControl frameworkDescription:Purpose of the task:1. Implement sub function $01 "StartRoutine" for routine 0x0203 "Check Reprogramming Preconditions":The routine shall check which conditions are currently not fulfilled for entering the programming session. It shall return the number of not fulfilled conditions and a list of those conditions.The CDD already specifies a list of unfulfilled conditions. Additional conditions might be added if required after consultation with the customer.The following reasons have been identified by now or require clarification:- 0x05: vehicle speed- 0x06: (1) Control is active or (2) EPB actuation is ongoing=> Please, note that condition (2) for reason 0x06 has not been specified by customer or System but it is expected that the condition will be specified by System in the future.Therefore, the check will be considered for the implementation of this routine. However, the stub ("IsEcuResetAllowedByPb") for the actual condition check will be kept as for the "Entering Programming Session" job ($10 02).2. As this is the first routine that is implemented for MMA, the task must also be used to adapt the Diag framework to support routines under the project-specific conditions.- Adaptations are required to support sub function $01 "StartRoutine" for service $31 "RoutineControl" with additional response bytes.- Therefore, the generic start routine handling shall be adapted.- The following SW pool components are affected: DiagArAdapter, DiagTestMgmtUnitGeneral:This task shall be used for SWE3 (design model update + implementation) + SWE4 (VCast).Details:1. Adapt SWC Diag:- Add service port for the new routine to SWC Diag and configure direction to server:- Add runnable for the new routine.=> Export updated Diag_AUTOSAR_Diag.arxml2. Framework adaptations:DiagArAdapter:- Adapt the interface GenericStartRoutineInterface:- new parameter list: const U16 test_id, const U8 *input_parameters, U8 *const output_parameters, const U8 param_length, U16 * const out_param_length, Dcm_NegativeResponseCodeType *ErrorCode- adapt the call of function CommandTest according to the new parameter list of the CommandInterface- Adapt the interface GenericStopRoutineInterface- adapt the call of function CommandTest according to the new parameter list of the CommandInterface- Adapt the interface GenericASyncShortTermAdjustmentInterface- adapt the call of function CommandTest according to the new parameter list of the CommandInterfaceTestGroup:- Adapt the interface CommandTest:- new parameter list: const U16 comms_id, const U8 test_type, const BOOLEAN command, const U8* const parameters, U8* const output_data, const U16 length, U16* const out_length- add a new block after the "Execute Command" block and before the "Update Group Status block":- check if "status" is TST_STATUS_OK and "out_length" is not NULL; if so call interface "ExecuteGetCommandDataInterface" and store the return value via "out_length" pointer- Add new type definition in the global header file for function pointer to retrieve the response parameters for start routine service request: typedef U16 (*GET_COMMAND_TEST_DATA_TYPE)(U8* results)TestSpecification:- Add new function U16 ExecuteGetCommandDataInterface(const U32 test_id, U8 results_buffer[]) with subsystem scope- the function shall check whether "GetCommandTestDataInterface" is not NULL for the given "test_id"- if so, it shall return the length returned by the respective "GetCommandTestDataInterface" interface.- otherwise, it shall return 0 as length.- Adapt definition of data type TEST_SPEC_DATA_TYPE:- add new paramter "GET_COMMAND_TEST_DATA_TYPE GetCommandTestDataInterface" behind the "Get_Result_Data_Inteface" parameterInputOutputControlById.c:- non functional adaptation to make the SW compile:- adapt the calls of function "CommandTest" in function "IoControlByIdentifier" to make the SW compile- pass NULL for the new parameters of "CommandTest"3. Implementation of routine 0x0203:DiagArAdapter_cfg:- Implement the new runnable "RoutineServices_Check_Reprogramming_Preconditions_Start":- define stack variables:- for 2nd parameter of CommandTest: const U8 start_routine_in_signals = 0u- for 3rd parameter of CommandTest (=> it is expected that a size of 8 bytes will be sufficient => currently a size of 2 bytes would be ok): U8 start_routine_out_signals[DIAG_PRGR_PRECND_MAX_DYN_LENGTH]- for 5th parameter of CommandTest: U16 data_length_out = 0u- OpStatus == DCM_initial:- call CommandTest with the listed parameters and with 1st parameter = PROG_PRECOND_CHECK_TEST_ID, with 4th parameter = 0 and with ErrorCode as 6th parameter- if returned data_length_out is less than minimal response length (= 2) or greater than minimal response legnth + size of array "start_routine_out_signals":- call UpdateTestManagementActive(FALSE)- return E_NOT_OK with ErrorCode DCM_E_GENERALREJECT- otherwise:- copy data from "start_routine_out_signals" to actual out parameters "routineInfo_Out", "Number_of_Unfulfilled_Preconditions_Out", "List_of_Preconditions_Out" and set "DataLength" to the correct value- return E_OK- OpStatus == DCM_CANCEL:- call UpdateTestManagementActive(FALSE)- return E_OK- OpStatus has another value:- return E_NOT_OK with ErrorCode DCM_E_GENERALREJECTTestSpecification_Cfg:- Adapt ROM table Test_Spec_Data: replace dummy entry with entry for routine 0x0203:{&CommandChkPrgrPrecnd,&UpdateChkPrgrPrecnd,NULL,NULL,&ReportChkPrgrPrecndCommandData,PROG_PRECOND_CHECK_TEST_ID,ROUTINE_BY_ID_TEST,EXCLUSIVE_TEST_GROUP,SECURITY_ACCESS_NOT_REQUIRED,PARAM_LENGTH_ZERO,(U8)IOC_NO_CHECK_REQUIRED}RoutineControl_Cfg:1. Implement Command_Interface with subsystem scope: CommandChkPrgrPrecnd- Check all programming preconditions by calling the following functions and store the check results in LOCAL variable:- CheckNonDefaultSessionSpeed()=> returns FALSE if speed is to high and programming session cannot be entered- (void)Rte_Read_R_BrakeActive_BrakeControlArbitratorActive(&BOOLEAN x) and (void)Rte_Read_R_ArbDriveTorque_DriveControlArbitratorActive(&BOOLEAN y)=> at least one function returns TRUE if a control intervention is active and programming session cannot be entered- IsEcuResetAllowedByPb()=> returns FALSE if EPB actuation is active and programming session cannot be entered2. Implement Update_Interface with subsystem scope: UpdateChkPrgrPrecnd- just return FALSE3. Implement GetCommandTestDataInterface with subsystem scope: ReportChkPrgrPrecndCommandData- set first response byte (DIAG_ROUTINE_STATUS_BYTE_INDEX) to 0x00 (DIAG_DAI_RID_SUCCESS_COMPLETED)- set second byte to the number of Programming PreConditions that are not fulfilled and prevent the system from entering the programming session => note: the number must be calculated in this function- if speed condition is unfulfilled, set next free response byte to 0x05 (DIAG_VEHICLE_SPEED_COND)- if control intervention or EPB actuation is in progress, set next free response byte to 0x06 (DIAG_CONTROLLER_ACTIVE_COND)- return the number of additional response bytes (= all bytes without pos. response byte + subfunction byte and RID bytes)Note:Please, find an untested(!) implementation proposal "Untested_Diag_ImplementatioProposal.zipx" attached to the task.Note that this implementation might not work correctly, and may cause QAC and polyspace warnings that needs to be fixed or handled.The proposal is based on SW checkpoint 1.3.3.142 with DiagArAdapter checkpoint 1.9.1.16 and DiagTestMgmtUnit checkpoint 1.8.2.7.Owner: Ashwini DigajerlaReviewer: C. WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 18h[Optional] Planned completion date: 25.05.2021 (set by task owner)TASK 5/5Title: [MMA][X0200][SWAD] Support new routine 0x0203 "Check Reprogramming Preconditions"Description:Please import and map requirements for stub implementation of the following routine:0x0203 "Check Reprogramming Preconditions" Map new runnable to OS task Task_DiagEvents_D_C0_1.Owner: C. KlukowskiReviewer: C. Bayer, C. WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 8h[Optional] Planned completion date: 27.05.2021 (set by task owner), LogType: Other
Summary: [Defect]: [Diag] ESP178: Session Handling-OTX - Check reprogramming precondition Not Implemented
Provide the details for the given Summary
ID: 5533079, Summary: [Defect]: [Diag] ESP178: Session Handling-OTX - Check reprogramming precondition Not Implemented, State: ALM_Closed, Project: /BRK/Customer/Daimler/MMA/IBC, Company: Daimler, Team: 4488191, Classification: Incident / Problem / Bug, Comments: [christian weyand (weyandc), jun 2, 2021 11:40:40 am cest]ccb-dc, weyandc: cr is closed after review.- [autosar] changes have been checked in with task 5292076. the task is linked to cr 5290840 which is linked to the same build as this cr.- [diag] related gaps regarding swe2, swe3 and swe4 will be handled with spawned cr 5323111.- [swad] task was canceled. the requested action will be performed with spawned cr 5346776 for sw_ad_backlog_x0200 with id 5323597.[christian rauh (rauhc), may 20, 2021 2:54:46 pm cest]dc-ccb: cr set to planned.[christian rauh (rauhc), may 20, 2021 2:54:24 pm cest]dc-ccb: cr approved.[christian rauh (rauhc), apr 14, 2021 3:28:49 pm cest]dc-ccb: please analyse and propose next steps., Description: This CR shall be used to implement the following diagnostic jobs:1. Check Reprogramming Preconditions - StartRoutine: $31 01 02 03 zz2. PreCheckProgrammingDependencies - StartRoutine: $31 01 02 07 zz Information:- The behavior of the routines is specified in the CDD but it must be checked whether further relevant customer requirements are specified in other specifications + DOORS modules.- The CR shall cover SWE1, SWE2, SWE3 and SWE4.- The CR has not be derived from BROP and/or DCRP but has been requested by the customer to be implemented for B1.1 (= X0150). Please, refer to the attached Excel Sheet "MMA_Diag_EffortEstimation_basedOn_v2.5_PlanningStatus_2021-04-08.xlsx" that is exchanged with the customer. To Diag CCB:- Please, add owner from Diag team.- Please, add analysers from Diag team and SwAD team., Conclusion: Brief analysis summary:19.05.2021 WeyandC:Routine 0x0203 "Check Reprogramming Preconditions" is not specified in DOORS module "EBS_Diagnostic_Requirements_Specification". But the routines is specified by the CDD and by specification "DDS R01-01".It is no longer requested by the customer that routine 0x0207 "PreCheckProgrammingDependencies" is supported by the application. This is why follow-up ALM_Change Request 5198683 has been or will be rejected.Purpose of the CR: 1. Implement sub function $01 "StartRoutine" for routine 0x0203 "Check Reprogramming Preconditions":The routine shall check which conditions are currently not fulfilled for entering the programming session. It shall return the number of not fulfilled conditions and a list of those conditions.The CDD already specifies a list of unfulfilled conditions. Additional conditions might be added if required after consultation with the customer.The following reasons have been identified and have been discussed with the customer: - 0x05: vehicle speed - 0x06: (1) Control is active or (2) EPB actuation is ongoing=> Please, note that condition (2) for reason 0x06 has not been specified by customer or System but it is expected that the condition will be specified by System in the future.Therefore, the check will be considered for the implementation of this routine. However, the stub ("IsEcuResetAllowedByPb") for the actual condition check will be kept as for the "Entering Programming Session" job ($10 02).2. As this is the first routine that is implemented for MMA, the CR must also be used to adapt the Diag framework to support routines under the project-specific conditions.- Adaptations are required to support sub function $01 "StartRoutine" for service $31 "RoutineControl" with additional response bytes.- Therefore, the generic start routine handling shall be adapted.- The following SW pool components are affected: DiagArAdapter, DiagTestMgmtUnitDIAG part: 1. Adapt SWC Diag- Add service port for the new routine to SWC Diag and configure direction to server:- Add runnable for the new routine.=> Export updated Diag_AUTOSAR_Diag.arxml.2. implementation of routine 0x0203 "Check Reprogramming Preconditions":=> Please, refer to the task description of the [SWE3/4][Diag] task for details: ALM_Task 53004693. Diag framework adaptations:=> Please, refer to the task description of the [SWE3/4][Diag] task for details: ALM_Task 5300469AUOTSAR part: - Import updated Diag_AUTOSAR_Diag.arxml.- Connect Dcm port to SWC Diag port for the new routine 0x0203 "Check Reprogramming Preconditions"- Map the new runnable to OS task Task_DiagEvents_D_C0_1. The slot is not relevant.=> Generate RTE and OS.NOTE: 1. SWC-Diag will call the following Autosar interfaces: - (void)Rte_Read_R_BrakeActive_BrakeControlArbitratorActive(&brake_ctrl_active); - (void)Rte_Read_R_ArbDriveTorque_DriveControlArbitratorActive(&drive_ctrl_active);The ports are still connected from Geely / VW (= baseline for the MMA project). No actions are required.The Autosar interfaces can be used from SwAD / Autosar point of view. Please, refer to the attached email "AW_ ALM_Change Request 5136349_ _MMA_Ő_Diag_ Implement _Programming Check_ routines.msg" for details.2. Diag Design:- It was decided for this routine that Dcm configuration is not manually adapted in DaVinci Configurator. The multiple in and out parameters are NOT replaced with a single in- and a single out-parameter. Hence, the DiagArAdapter routine runnable must copy data from the multiple in-parameters to the single generic Diag in-parameter and vice versa from the single Diag generic out-parameter to the multiple out-parameters.- It was also decided that stack variables (= function variables) will be used as the additional stack consumption is negligible.- For the future, it will be check whether the Dcm configuration will be manually adapted in DaVinci Configurator for new routines or whether shared Diag RAM variables shall be used to copy data between parameters defined by Autosar and generic Diag parameters.=> Both decision will not affect the implementation of routine 0x0203 that is provided with this CR.Risk (low/medium/high):mediumAnalysis completed by (applicable only for distributed analyses): WeyandC, SwAD part confirmed by C. Klukowski, Autosar task proposal confirmed by S. Basavaraju via TeamsProposal of next steps (incl. effort/h and verification):TASK 1/5Title: [MMA][Autosar][X0200] Connect ports between Dcm and SWC DIAG and map ports to OS tasks for routine 0x0203Description:- Import updated Diag_AUTOSAR_Diag.arxml.- Connect Dcm port to SWC Diag port for the new routine: 0x0203 "Check Reprogramming Preconditions"- Map the new runnable for the routine to OS task Task_DiagEvents_D_C0_1. The slot is not relevant.=> Generate RTE, and OS.Owner: Hemanth AmbarukhanaReviewer: Sireesha Basavaraju, C. WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 7h[Optional] Planned completion date: 26.05.2021 (set by task owner)TASK 2/5Title: [MMA][Diag][SWE1][X0200] Support new routine 0x0203 "Check Reprogramming Preconditions"Description:The following DIDs routine be implemented with this CR: Routine 0x0203 "Check Reprogramming Preconditions" with sub function $01 "StartRoutine" is specified by the CDD and by specification "DDS R01-01". Functionality:The routine shall check which conditions are currently not fulfilled for entering the programming session. It shall return the number of not fulfilled conditions and a list of those conditions.The CDD already specifies a list of unfulfilled conditions. Additional conditions might be added if required after consultation with the customer.The following reasons have been identified by now or require clarification:- 0x05: vehicle speed- 0x06: (1) Control is active or (2) EPB actuation is ongoing=> Please, note that condition (2) for reason 0x06 has not been specified by customer or System but it is expected that the condition will be specified by System in the future. Therefore, the check will be considered for the implementation of this routine. However, the stub ("IsEcuResetAllowedByPb") for the actual condition check will be kept as for the "Entering Programming Session" job ($10 02). Refer to the attached emails for further details. Please, use this CR to define SW requirements for this routine.Owner: J. HornungReviewer: C. WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 4h[Optional] Planned completion date: 26.05.2021TASK 3/5Title: [MMA][Diag][SWE2][X0200] Support new routine 0x0203 "Check Reprogramming Preconditions"Description:(SWE2) Please update SwAD model according to derived requirements. The CR is used to implement routine 0x0203 "Check Reprogramming Preconditions".Please, note that SW requirements might not be available in time. In that case, it must be checked whether a follow-up CR needs to be created.Owner: C. WeyandReviewer: A. ElfekyEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 4h[Optional] Planned completion date: 28.05.2021TASK 4/5Title: [MMA][Diag][SWE3/4][X0200] Implement routine 0x0203 "Check Reprogramming Preconditions" and adapt RoutineControl frameworkDescription:Purpose of the task:1. Implement sub function $01 "StartRoutine" for routine 0x0203 "Check Reprogramming Preconditions":The routine shall check which conditions are currently not fulfilled for entering the programming session. It shall return the number of not fulfilled conditions and a list of those conditions.The CDD already specifies a list of unfulfilled conditions. Additional conditions might be added if required after consultation with the customer.The following reasons have been identified by now or require clarification:- 0x05: vehicle speed- 0x06: (1) Control is active or (2) EPB actuation is ongoing=> Please, note that condition (2) for reason 0x06 has not been specified by customer or System but it is expected that the condition will be specified by System in the future.Therefore, the check will be considered for the implementation of this routine. However, the stub ("IsEcuResetAllowedByPb") for the actual condition check will be kept as for the "Entering Programming Session" job ($10 02).2. As this is the first routine that is implemented for MMA, the task must also be used to adapt the Diag framework to support routines under the project-specific conditions.- Adaptations are required to support sub function $01 "StartRoutine" for service $31 "RoutineControl" with additional response bytes.- Therefore, the generic start routine handling shall be adapted.- The following SW pool components are affected: DiagArAdapter, DiagTestMgmtUnitGeneral:This task shall be used for SWE3 (design model update + implementation) + SWE4 (VCast).Details:1. Adapt SWC Diag:- Add service port for the new routine to SWC Diag and configure direction to server:- Add runnable for the new routine.=> Export updated Diag_AUTOSAR_Diag.arxml2. Framework adaptations:DiagArAdapter:- Adapt the interface GenericStartRoutineInterface:- new parameter list: const U16 test_id, const U8 *input_parameters, U8 *const output_parameters, const U8 param_length, U16 * const out_param_length, Dcm_NegativeResponseCodeType *ErrorCode- adapt the call of function CommandTest according to the new parameter list of the CommandInterface- Adapt the interface GenericStopRoutineInterface- adapt the call of function CommandTest according to the new parameter list of the CommandInterface- Adapt the interface GenericASyncShortTermAdjustmentInterface- adapt the call of function CommandTest according to the new parameter list of the CommandInterfaceTestGroup:- Adapt the interface CommandTest:- new parameter list: const U16 comms_id, const U8 test_type, const BOOLEAN command, const U8* const parameters, U8* const output_data, const U16 length, U16* const out_length- add a new block after the "Execute Command" block and before the "Update Group Status block":- check if "status" is TST_STATUS_OK and "out_length" is not NULL; if so call interface "ExecuteGetCommandDataInterface" and store the return value via "out_length" pointer- Add new type definition in the global header file for function pointer to retrieve the response parameters for start routine service request: typedef U16 (*GET_COMMAND_TEST_DATA_TYPE)(U8* results)TestSpecification:- Add new function U16 ExecuteGetCommandDataInterface(const U32 test_id, U8 results_buffer[]) with subsystem scope- the function shall check whether "GetCommandTestDataInterface" is not NULL for the given "test_id"- if so, it shall return the length returned by the respective "GetCommandTestDataInterface" interface.- otherwise, it shall return 0 as length.- Adapt definition of data type TEST_SPEC_DATA_TYPE:- add new paramter "GET_COMMAND_TEST_DATA_TYPE GetCommandTestDataInterface" behind the "Get_Result_Data_Inteface" parameterInputOutputControlById.c:- non functional adaptation to make the SW compile:- adapt the calls of function "CommandTest" in function "IoControlByIdentifier" to make the SW compile- pass NULL for the new parameters of "CommandTest"3. Implementation of routine 0x0203:DiagArAdapter_cfg:- Implement the new runnable "RoutineServices_Check_Reprogramming_Preconditions_Start":- define stack variables:- for 2nd parameter of CommandTest: const U8 start_routine_in_signals = 0u- for 3rd parameter of CommandTest (=> it is expected that a size of 8 bytes will be sufficient => currently a size of 2 bytes would be ok): U8 start_routine_out_signals[DIAG_PRGR_PRECND_MAX_DYN_LENGTH]- for 5th parameter of CommandTest: U16 data_length_out = 0u- OpStatus == DCM_initial:- call CommandTest with the listed parameters and with 1st parameter = PROG_PRECOND_CHECK_TEST_ID, with 4th parameter = 0 and with ErrorCode as 6th parameter- if returned data_length_out is less than minimal response length (= 2) or greater than minimal response legnth + size of array "start_routine_out_signals":- call UpdateTestManagementActive(FALSE)- return E_NOT_OK with ErrorCode DCM_E_GENERALREJECT- otherwise:- copy data from "start_routine_out_signals" to actual out parameters "routineInfo_Out", "Number_of_Unfulfilled_Preconditions_Out", "List_of_Preconditions_Out" and set "DataLength" to the correct value- return E_OK- OpStatus == DCM_CANCEL:- call UpdateTestManagementActive(FALSE)- return E_OK- OpStatus has another value:- return E_NOT_OK with ErrorCode DCM_E_GENERALREJECTTestSpecification_Cfg:- Adapt ROM table Test_Spec_Data: replace dummy entry with entry for routine 0x0203:{&CommandChkPrgrPrecnd,&UpdateChkPrgrPrecnd,NULL,NULL,&ReportChkPrgrPrecndCommandData,PROG_PRECOND_CHECK_TEST_ID,ROUTINE_BY_ID_TEST,EXCLUSIVE_TEST_GROUP,SECURITY_ACCESS_NOT_REQUIRED,PARAM_LENGTH_ZERO,(U8)IOC_NO_CHECK_REQUIRED}RoutineControl_Cfg:1. Implement Command_Interface with subsystem scope: CommandChkPrgrPrecnd- Check all programming preconditions by calling the following functions and store the check results in LOCAL variable:- CheckNonDefaultSessionSpeed()=> returns FALSE if speed is to high and programming session cannot be entered- (void)Rte_Read_R_BrakeActive_BrakeControlArbitratorActive(&BOOLEAN x) and (void)Rte_Read_R_ArbDriveTorque_DriveControlArbitratorActive(&BOOLEAN y)=> at least one function returns TRUE if a control intervention is active and programming session cannot be entered- IsEcuResetAllowedByPb()=> returns FALSE if EPB actuation is active and programming session cannot be entered2. Implement Update_Interface with subsystem scope: UpdateChkPrgrPrecnd- just return FALSE3. Implement GetCommandTestDataInterface with subsystem scope: ReportChkPrgrPrecndCommandData- set first response byte (DIAG_ROUTINE_STATUS_BYTE_INDEX) to 0x00 (DIAG_DAI_RID_SUCCESS_COMPLETED)- set second byte to the number of Programming PreConditions that are not fulfilled and prevent the system from entering the programming session => note: the number must be calculated in this function- if speed condition is unfulfilled, set next free response byte to 0x05 (DIAG_VEHICLE_SPEED_COND)- if control intervention or EPB actuation is in progress, set next free response byte to 0x06 (DIAG_CONTROLLER_ACTIVE_COND)- return the number of additional response bytes (= all bytes without pos. response byte + subfunction byte and RID bytes)Note:Please, find an untested(!) implementation proposal "Untested_Diag_ImplementatioProposal.zipx" attached to the task.Note that this implementation might not work correctly, and may cause QAC and polyspace warnings that needs to be fixed or handled.The proposal is based on SW checkpoint 1.3.3.142 with DiagArAdapter checkpoint 1.9.1.16 and DiagTestMgmtUnit checkpoint 1.8.2.7.Owner: Ashwini DigajerlaReviewer: C. WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 18h[Optional] Planned completion date: 25.05.2021 (set by task owner)TASK 5/5Title: [MMA][X0200][SWAD] Support new routine 0x0203 "Check Reprogramming Preconditions"Description:Please import and map requirements for stub implementation of the following routine:0x0203 "Check Reprogramming Preconditions" Map new runnable to OS task Task_DiagEvents_D_C0_1.Owner: C. KlukowskiReviewer: C. Bayer, C. WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 8h[Optional] Planned completion date: 27.05.2021 (set by task owner), LogType: Other
LogType: Other, Company: Daimler, Summary: [Defect]: [Diag] ESP178: Session Handling-OTX - Check reprogramming precondition Not Implemented
Provide the details for the given input
ID: 5533074, Summary: [Defect]: [Diag] ESP178: ID-Data services not implemented, State: ALM_Closed, Project: /BRK/Customer/Daimler/MMA/IBC, Company: Daimler, Team: 4488189, Classification: Incident / Problem / Bug, Comments: [christian rauh (rauhc), may 7, 2021 10:03:58 am cest]dc-ccb: cr closed after formal review.[(system user) user for queue manager (scs_queuemanager), may 5, 2021 8:43:38 pm cest]preintegration of 5204252 was successful. a checkpoint has been created on path #/brk#customer/daimler/mma/ibc/05_software/view_mainline/mmc_appl#d=iqm_preinteg_da31_p05_m10_s02_vtx. checkpoint number is 1.3.3.127.[christian weyand (weyandc), may 5, 2021 8:49:00 am cest]dc-ccb: owner of reviewer 5197065 was changed as originally intended reviewer is not available.[(system user) user for queue manager (scs_queuemanager), may 4, 2021 9:05:55 pm cest]preintegration of 5204252 was successful. a checkpoint has been created on path #/brk#customer/daimler/mma/ibc/05_software/view_mainline/mmc_appl#d=iqm_preinteg_da31_p05_m10_s02_vtx. checkpoint number is 1.3.3.126.[christian rauh (rauhc), apr 28, 2021 6:55:54 am cest]dc-ccb: cr approved.[christian rauh (rauhc), jan 12, 2021 11:15:15 am cet]dc-ccb: please analyse and propose next steps., Description: Aim (Objective and Rationale): Feature implementation of [DCRP 46.1] SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Maturity Level: ML1 / Note Basic Technology Rollout Plan (BROP) - Milestone B1 As part of 'Work step: Perform Preliminary Impact Analysis' in stages https://cdc-stages.emea.zf-world.com:8443/pkit/go/pelement.do?id=469319&type=Subprocess following teams are identified, which are impacted by the customer requirements.Diag, Comms, Security, Memo Please assign as 'Owners'; DiagPlease assign as 'Analysers'; Diag, Memo, SwAD.Details (Exact description):Doing by SwD:(SWE1)Please derive requirements from the 'Source' (for 'Source' refer below) and map the behavior to the derived requirements(SWE2)Please update SwAD model according to derived requirements.(SWE3)Please develop a sw design (RPY model) and implement the behaviors according to the derived requirements.(SWE4)Please develop sw unit tests according to the derived requirements.Doing by SwAD:(SwAD)Import the derived requirements into SwAD model.Input Work Products (Link or other reference): Source (customer requirements): refer attached excel sheet 'MMA_Diag_Customer_Reqs_v1.1_SwAD.xlsx' ,please filter column 'N' 'Diag Cluster ID' for the value of 16Link to customer requirements: http://skobde-doors9wa.ad.trw.com:8080/dwa/rm/urn:rational:e9aba799-bc96-11e5-b6b9-419012b199da:1-479f06bc41562230-M-0011ac00 The attachment 'MMA_Diag_Customer_Reqs_v1.1_SwAD.xlsx' is an export of the customer DOORS module 'EBS Diagnostic Requirements Specification', current 29.1, which contains additional columns:'F' (Provider of information),'G' (Behavior),'H' (Involved team).Description of the additional columns based on an example:'C': DIAG_2119;'E': 'The service Read DTC Information (SID $19) shall be supported, with all in this requirement specification defined "DTC Information''F': This column contains the teams or the behavior which support the implementation of this requirement by the behavior in column 'G', e.g. to provide information/interface to fulfill the requirement. In this case Fm has to provide an interface.'G': Behavior: This column contains the behavior(s) which have to implement the customer requirement. In this case the customer requirement shall be implemented by the in column 'G' mentioned behavior(s).'H': This column contains the teams which are impacted by this requirement, team might be in supporting role (refer column 'F') and other in 'responsible role' to implement the behavior (refer column'H'). Output Work Products:Refer stagesAcceptance Criteria:The requirements are derived.SwAD model updated according to derived requirements.Sw design (RPY model) and implementation of the behaviors according to the derived requirements is done.sw unit tests according to the derived requirements are developed.Derived requirements are mapped to behaviors and imported to Domain Architecture.In case of gaps/incompleteness/incorrectness which shall not be resolved with particular Task (where the review has failed), only 'ONE' follow up CR shall be created which covers all findings of all Tasks of that CR (purpose: reduction of CRs).This must be agreed with the SwPM and the CR must be planned by SwPM.This CR must be spawned by the parent CR of the failed Task.Responsibility to provide the findings which shall be solved with another CR into the another CR belongs to the Owner of this Task. The reviewer should complete/close the Task only if the findings are documented in the follow up CR.Example how the follow-up CR might look:Summary: [FollowUp] <Summary_Of_CR_spawnedBy>Description:'This CR is a follow-up CR of <ID_of_CR_spawnedBy>.With this CR the findings shall be resolved, which were identified during the review of the Task(s) attached to the CR <ID_of_CR_spawnedBy>.It is agreed with SwPM to shift the correction of the findings to another build.Task: <ID of Task with Findings>Refer attachment 'ReviewFindingsOfTask_<ID of Task with Findings>'.', Conclusion: Brief analysis summary:22.04.2021Ashwini DigajerlaDig team:As per cluster ID 16 below DIDs has to be implemented.-Read ECU Name(c)-Read Supported configuration mechanisms(0xF131)-Read DID for Snapshot-Date: Vehicle Odometer in LowResolution(0x010A)-Read DID for Snapshot-Date: Current Operating Time(0x0133)Due to non availbility of the required interfaces for DID 0x010A and 0x0133 from Coms and FM subsytems ,seperate Spawn CR is created for implementing this 2 DIDs.Req Reference:Cdd file from D:\Daimbler\VariantSB\DiagMain\Cfg\Model Davini Configarator changes: ->Although all diagnostic jobs are already configured in the Dcm configuration, a Dcm configuration update will be required with this CR 4861342 .This is because:1. “Dsp Data Use Port” shall be changed to “USE_DATA_SYNCH_CLIENT_SERVER” As the callout will never return “pending”.->Task mapping for the RTE calls shall be done.Davini Developer changes: ->Create new runnables for 0xF101 and 0xF103 DIDs and generated DCM and RTE.Diag Application changes: Code Changes:-> Implement Read functions in DiagArAdapter_Cfg.c file->Add Read functions for 2 DIDs in the file \ReadDataByIdentifier_Cfg_Priv.h .-> In ReadDataByIdentifier_Cfg.c file add the call back functions in lookup table and implement functions to read the data.-> Add required macros to the corresponding ReadDataByIdentifier_Cfg.h. and ReadDataByIdentifier_Cfg_sub.h files.->only ROM data will be read with the 2 DIDs->Attached code changes.-> No actions required by MeMo,FM and coms team for this CR. 26.04.2021 WeyandC: Ooi Siang Tan has been removed from the list of analysers as MeMo team is not involved in this CR. Please, refer to the attached email "AW_ _DCRP 46_1_ _IBC__SW-D_ SF 8_8 System Diagnostic Function -Read ID-Data_ Remaining jobs_ Cluster ID 16.msg". Risk (low/medium/high): lowAnalysis completed by (applicable only for distributed analyses): Ashwini Digajerla . TASKTitle: [SWE1/4][Diag] SF 8.8 System Diagnostic Function Read ID-Data: Remaining jobs, Cluster ID 16Description:(SWE1) Please, provide Sw requirements for the customer requirements that specify diagnostic service: 0xF104,0xF131Link to customer requirements: http://skobde-doors9wa.ad.trw.com:8080/dwa/rm/urn:rational:e9aba799-bc96-11e5-b6b9-419012b199da:1-479f06bc41562230-M-0011ac00 Owner: Joachim HornungReviewer: Christian WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 4h[Optional] Planned completion date:TASKTitle: [SWE2/4][Diag] SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Description:(SWE2) Please update SwAD model according to derived requirements. The CR is used to implement diagnsotic service :0xF104,0xF131Please, note that SW requirements might not be available in time. In that case, it must be checked whether a follow-up CR needs to be created.Owner: Christian WeyandReviewer: Ahmed ElfekyEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 7h[Optional] Planned completion date: 30.04.2021 TASKTitle: [SWE3/4][Diag] SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Description:Implement Diag application part to support DIDs 0xF104 and 0xF131 . The task shall be used:1. to update the design model2. to implement the requested functionality including QAC, polyspace and log file analysis3. and to update / add VCast tests, execute them and link them to the design model. Details for point 2: The implementation in diagnostic application needs to be adapted with below new DIDs.-Read ECU Name(0xF104)-Read Supported configuration mechanisms(0xF131)Davini Configarator changes: ->Although all diagnostic jobs are already configured in the Dcm configuration, a Dcm configuration update will be required with this CR 4861342 .This is because:1. “Dsp Data Use Port” shall be changed to “USE_DATA_SYNCH_CLIENT_SERVER” As the callout will never return “pending”.->Task mapping for the RTE calls shall be done.Davini Developer changes: ->Create new runnables for 0xF101 and 0xF103 DIDs and generated DCM and RTE.Diag Application changes: Code Changes:-> Implement Read functions in DiagArAdapter_Cfg.c file->Add Read functions for 2 DIDs in the file \ReadDataByIdentifier_Cfg_Priv.h .-> In ReadDataByIdentifier_Cfg.c file add the call back functions in lookup table and implement functions to read the data.-> Add required macros to the corresponding ReadDataByIdentifier_Cfg.h. and ReadDataByIdentifier_Cfg_sub.h files.->only ROM data will be read with the 2 DIDs->Attached code changes.-> No actions required by MeMo,FM and coms team for this CR. Owner: Irannavar Satish Pundalik EXT HDR Tata ElxsiReviewer: Ashwini DigajerlaEstimated design effort/h:6Estimated implementation effort/h:6Estimated unit testing effort/h:18Total effort/h: 30h[Optional] Planned completion date: 30.04.2021 Task SwAD:Title:(SWE4/4)SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Description: Please import and map requirements.Owner:Caesar KlukowskiReviewer: Christoph Bayer, Christian WeyandTotal effort/h: 8[Optional] Planned completion date: 4.5.2021 Task AUTOSAR:Title:SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Description:->With new Arxml provided by Diag task ,create new service ports and runnables for 0xF101 and 0xF103 DIDs .->Do task mapping for the new runnables in configarator . .->Generated DCM and RTE and checkin the changes.Owner: Sireesha BasavarajuReviewer: Hemanth Ambarukhana KrishnaTotal effort/h: 8[Optional] Planned completion date: 30.4.2021, LogType: Other
ID: 5533074
Provide the details for the given ID
ID: 5533074, Summary: [Defect]: [Diag] ESP178: ID-Data services not implemented, State: ALM_Closed, Project: /BRK/Customer/Daimler/MMA/IBC, Company: Daimler, Team: 4488189, Classification: Incident / Problem / Bug, Comments: [christian rauh (rauhc), may 7, 2021 10:03:58 am cest]dc-ccb: cr closed after formal review.[(system user) user for queue manager (scs_queuemanager), may 5, 2021 8:43:38 pm cest]preintegration of 5204252 was successful. a checkpoint has been created on path #/brk#customer/daimler/mma/ibc/05_software/view_mainline/mmc_appl#d=iqm_preinteg_da31_p05_m10_s02_vtx. checkpoint number is 1.3.3.127.[christian weyand (weyandc), may 5, 2021 8:49:00 am cest]dc-ccb: owner of reviewer 5197065 was changed as originally intended reviewer is not available.[(system user) user for queue manager (scs_queuemanager), may 4, 2021 9:05:55 pm cest]preintegration of 5204252 was successful. a checkpoint has been created on path #/brk#customer/daimler/mma/ibc/05_software/view_mainline/mmc_appl#d=iqm_preinteg_da31_p05_m10_s02_vtx. checkpoint number is 1.3.3.126.[christian rauh (rauhc), apr 28, 2021 6:55:54 am cest]dc-ccb: cr approved.[christian rauh (rauhc), jan 12, 2021 11:15:15 am cet]dc-ccb: please analyse and propose next steps., Description: Aim (Objective and Rationale): Feature implementation of [DCRP 46.1] SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Maturity Level: ML1 / Note Basic Technology Rollout Plan (BROP) - Milestone B1 As part of 'Work step: Perform Preliminary Impact Analysis' in stages https://cdc-stages.emea.zf-world.com:8443/pkit/go/pelement.do?id=469319&type=Subprocess following teams are identified, which are impacted by the customer requirements.Diag, Comms, Security, Memo Please assign as 'Owners'; DiagPlease assign as 'Analysers'; Diag, Memo, SwAD.Details (Exact description):Doing by SwD:(SWE1)Please derive requirements from the 'Source' (for 'Source' refer below) and map the behavior to the derived requirements(SWE2)Please update SwAD model according to derived requirements.(SWE3)Please develop a sw design (RPY model) and implement the behaviors according to the derived requirements.(SWE4)Please develop sw unit tests according to the derived requirements.Doing by SwAD:(SwAD)Import the derived requirements into SwAD model.Input Work Products (Link or other reference): Source (customer requirements): refer attached excel sheet 'MMA_Diag_Customer_Reqs_v1.1_SwAD.xlsx' ,please filter column 'N' 'Diag Cluster ID' for the value of 16Link to customer requirements: http://skobde-doors9wa.ad.trw.com:8080/dwa/rm/urn:rational:e9aba799-bc96-11e5-b6b9-419012b199da:1-479f06bc41562230-M-0011ac00 The attachment 'MMA_Diag_Customer_Reqs_v1.1_SwAD.xlsx' is an export of the customer DOORS module 'EBS Diagnostic Requirements Specification', current 29.1, which contains additional columns:'F' (Provider of information),'G' (Behavior),'H' (Involved team).Description of the additional columns based on an example:'C': DIAG_2119;'E': 'The service Read DTC Information (SID $19) shall be supported, with all in this requirement specification defined "DTC Information''F': This column contains the teams or the behavior which support the implementation of this requirement by the behavior in column 'G', e.g. to provide information/interface to fulfill the requirement. In this case Fm has to provide an interface.'G': Behavior: This column contains the behavior(s) which have to implement the customer requirement. In this case the customer requirement shall be implemented by the in column 'G' mentioned behavior(s).'H': This column contains the teams which are impacted by this requirement, team might be in supporting role (refer column 'F') and other in 'responsible role' to implement the behavior (refer column'H'). Output Work Products:Refer stagesAcceptance Criteria:The requirements are derived.SwAD model updated according to derived requirements.Sw design (RPY model) and implementation of the behaviors according to the derived requirements is done.sw unit tests according to the derived requirements are developed.Derived requirements are mapped to behaviors and imported to Domain Architecture.In case of gaps/incompleteness/incorrectness which shall not be resolved with particular Task (where the review has failed), only 'ONE' follow up CR shall be created which covers all findings of all Tasks of that CR (purpose: reduction of CRs).This must be agreed with the SwPM and the CR must be planned by SwPM.This CR must be spawned by the parent CR of the failed Task.Responsibility to provide the findings which shall be solved with another CR into the another CR belongs to the Owner of this Task. The reviewer should complete/close the Task only if the findings are documented in the follow up CR.Example how the follow-up CR might look:Summary: [FollowUp] <Summary_Of_CR_spawnedBy>Description:'This CR is a follow-up CR of <ID_of_CR_spawnedBy>.With this CR the findings shall be resolved, which were identified during the review of the Task(s) attached to the CR <ID_of_CR_spawnedBy>.It is agreed with SwPM to shift the correction of the findings to another build.Task: <ID of Task with Findings>Refer attachment 'ReviewFindingsOfTask_<ID of Task with Findings>'.', Conclusion: Brief analysis summary:22.04.2021Ashwini DigajerlaDig team:As per cluster ID 16 below DIDs has to be implemented.-Read ECU Name(c)-Read Supported configuration mechanisms(0xF131)-Read DID for Snapshot-Date: Vehicle Odometer in LowResolution(0x010A)-Read DID for Snapshot-Date: Current Operating Time(0x0133)Due to non availbility of the required interfaces for DID 0x010A and 0x0133 from Coms and FM subsytems ,seperate Spawn CR is created for implementing this 2 DIDs.Req Reference:Cdd file from D:\Daimbler\VariantSB\DiagMain\Cfg\Model Davini Configarator changes: ->Although all diagnostic jobs are already configured in the Dcm configuration, a Dcm configuration update will be required with this CR 4861342 .This is because:1. “Dsp Data Use Port” shall be changed to “USE_DATA_SYNCH_CLIENT_SERVER” As the callout will never return “pending”.->Task mapping for the RTE calls shall be done.Davini Developer changes: ->Create new runnables for 0xF101 and 0xF103 DIDs and generated DCM and RTE.Diag Application changes: Code Changes:-> Implement Read functions in DiagArAdapter_Cfg.c file->Add Read functions for 2 DIDs in the file \ReadDataByIdentifier_Cfg_Priv.h .-> In ReadDataByIdentifier_Cfg.c file add the call back functions in lookup table and implement functions to read the data.-> Add required macros to the corresponding ReadDataByIdentifier_Cfg.h. and ReadDataByIdentifier_Cfg_sub.h files.->only ROM data will be read with the 2 DIDs->Attached code changes.-> No actions required by MeMo,FM and coms team for this CR. 26.04.2021 WeyandC: Ooi Siang Tan has been removed from the list of analysers as MeMo team is not involved in this CR. Please, refer to the attached email "AW_ _DCRP 46_1_ _IBC__SW-D_ SF 8_8 System Diagnostic Function -Read ID-Data_ Remaining jobs_ Cluster ID 16.msg". Risk (low/medium/high): lowAnalysis completed by (applicable only for distributed analyses): Ashwini Digajerla . TASKTitle: [SWE1/4][Diag] SF 8.8 System Diagnostic Function Read ID-Data: Remaining jobs, Cluster ID 16Description:(SWE1) Please, provide Sw requirements for the customer requirements that specify diagnostic service: 0xF104,0xF131Link to customer requirements: http://skobde-doors9wa.ad.trw.com:8080/dwa/rm/urn:rational:e9aba799-bc96-11e5-b6b9-419012b199da:1-479f06bc41562230-M-0011ac00 Owner: Joachim HornungReviewer: Christian WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 4h[Optional] Planned completion date:TASKTitle: [SWE2/4][Diag] SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Description:(SWE2) Please update SwAD model according to derived requirements. The CR is used to implement diagnsotic service :0xF104,0xF131Please, note that SW requirements might not be available in time. In that case, it must be checked whether a follow-up CR needs to be created.Owner: Christian WeyandReviewer: Ahmed ElfekyEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 7h[Optional] Planned completion date: 30.04.2021 TASKTitle: [SWE3/4][Diag] SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Description:Implement Diag application part to support DIDs 0xF104 and 0xF131 . The task shall be used:1. to update the design model2. to implement the requested functionality including QAC, polyspace and log file analysis3. and to update / add VCast tests, execute them and link them to the design model. Details for point 2: The implementation in diagnostic application needs to be adapted with below new DIDs.-Read ECU Name(0xF104)-Read Supported configuration mechanisms(0xF131)Davini Configarator changes: ->Although all diagnostic jobs are already configured in the Dcm configuration, a Dcm configuration update will be required with this CR 4861342 .This is because:1. “Dsp Data Use Port” shall be changed to “USE_DATA_SYNCH_CLIENT_SERVER” As the callout will never return “pending”.->Task mapping for the RTE calls shall be done.Davini Developer changes: ->Create new runnables for 0xF101 and 0xF103 DIDs and generated DCM and RTE.Diag Application changes: Code Changes:-> Implement Read functions in DiagArAdapter_Cfg.c file->Add Read functions for 2 DIDs in the file \ReadDataByIdentifier_Cfg_Priv.h .-> In ReadDataByIdentifier_Cfg.c file add the call back functions in lookup table and implement functions to read the data.-> Add required macros to the corresponding ReadDataByIdentifier_Cfg.h. and ReadDataByIdentifier_Cfg_sub.h files.->only ROM data will be read with the 2 DIDs->Attached code changes.-> No actions required by MeMo,FM and coms team for this CR. Owner: Irannavar Satish Pundalik EXT HDR Tata ElxsiReviewer: Ashwini DigajerlaEstimated design effort/h:6Estimated implementation effort/h:6Estimated unit testing effort/h:18Total effort/h: 30h[Optional] Planned completion date: 30.04.2021 Task SwAD:Title:(SWE4/4)SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Description: Please import and map requirements.Owner:Caesar KlukowskiReviewer: Christoph Bayer, Christian WeyandTotal effort/h: 8[Optional] Planned completion date: 4.5.2021 Task AUTOSAR:Title:SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Description:->With new Arxml provided by Diag task ,create new service ports and runnables for 0xF101 and 0xF103 DIDs .->Do task mapping for the new runnables in configarator . .->Generated DCM and RTE and checkin the changes.Owner: Sireesha BasavarajuReviewer: Hemanth Ambarukhana KrishnaTotal effort/h: 8[Optional] Planned completion date: 30.4.2021, LogType: Other
Summary: [Defect]: [Diag] ESP178: ID-Data services not implemented
Provide the details for the given Summary
ID: 5533074, Summary: [Defect]: [Diag] ESP178: ID-Data services not implemented, State: ALM_Closed, Project: /BRK/Customer/Daimler/MMA/IBC, Company: Daimler, Team: 4488189, Classification: Incident / Problem / Bug, Comments: [christian rauh (rauhc), may 7, 2021 10:03:58 am cest]dc-ccb: cr closed after formal review.[(system user) user for queue manager (scs_queuemanager), may 5, 2021 8:43:38 pm cest]preintegration of 5204252 was successful. a checkpoint has been created on path #/brk#customer/daimler/mma/ibc/05_software/view_mainline/mmc_appl#d=iqm_preinteg_da31_p05_m10_s02_vtx. checkpoint number is 1.3.3.127.[christian weyand (weyandc), may 5, 2021 8:49:00 am cest]dc-ccb: owner of reviewer 5197065 was changed as originally intended reviewer is not available.[(system user) user for queue manager (scs_queuemanager), may 4, 2021 9:05:55 pm cest]preintegration of 5204252 was successful. a checkpoint has been created on path #/brk#customer/daimler/mma/ibc/05_software/view_mainline/mmc_appl#d=iqm_preinteg_da31_p05_m10_s02_vtx. checkpoint number is 1.3.3.126.[christian rauh (rauhc), apr 28, 2021 6:55:54 am cest]dc-ccb: cr approved.[christian rauh (rauhc), jan 12, 2021 11:15:15 am cet]dc-ccb: please analyse and propose next steps., Description: Aim (Objective and Rationale): Feature implementation of [DCRP 46.1] SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Maturity Level: ML1 / Note Basic Technology Rollout Plan (BROP) - Milestone B1 As part of 'Work step: Perform Preliminary Impact Analysis' in stages https://cdc-stages.emea.zf-world.com:8443/pkit/go/pelement.do?id=469319&type=Subprocess following teams are identified, which are impacted by the customer requirements.Diag, Comms, Security, Memo Please assign as 'Owners'; DiagPlease assign as 'Analysers'; Diag, Memo, SwAD.Details (Exact description):Doing by SwD:(SWE1)Please derive requirements from the 'Source' (for 'Source' refer below) and map the behavior to the derived requirements(SWE2)Please update SwAD model according to derived requirements.(SWE3)Please develop a sw design (RPY model) and implement the behaviors according to the derived requirements.(SWE4)Please develop sw unit tests according to the derived requirements.Doing by SwAD:(SwAD)Import the derived requirements into SwAD model.Input Work Products (Link or other reference): Source (customer requirements): refer attached excel sheet 'MMA_Diag_Customer_Reqs_v1.1_SwAD.xlsx' ,please filter column 'N' 'Diag Cluster ID' for the value of 16Link to customer requirements: http://skobde-doors9wa.ad.trw.com:8080/dwa/rm/urn:rational:e9aba799-bc96-11e5-b6b9-419012b199da:1-479f06bc41562230-M-0011ac00 The attachment 'MMA_Diag_Customer_Reqs_v1.1_SwAD.xlsx' is an export of the customer DOORS module 'EBS Diagnostic Requirements Specification', current 29.1, which contains additional columns:'F' (Provider of information),'G' (Behavior),'H' (Involved team).Description of the additional columns based on an example:'C': DIAG_2119;'E': 'The service Read DTC Information (SID $19) shall be supported, with all in this requirement specification defined "DTC Information''F': This column contains the teams or the behavior which support the implementation of this requirement by the behavior in column 'G', e.g. to provide information/interface to fulfill the requirement. In this case Fm has to provide an interface.'G': Behavior: This column contains the behavior(s) which have to implement the customer requirement. In this case the customer requirement shall be implemented by the in column 'G' mentioned behavior(s).'H': This column contains the teams which are impacted by this requirement, team might be in supporting role (refer column 'F') and other in 'responsible role' to implement the behavior (refer column'H'). Output Work Products:Refer stagesAcceptance Criteria:The requirements are derived.SwAD model updated according to derived requirements.Sw design (RPY model) and implementation of the behaviors according to the derived requirements is done.sw unit tests according to the derived requirements are developed.Derived requirements are mapped to behaviors and imported to Domain Architecture.In case of gaps/incompleteness/incorrectness which shall not be resolved with particular Task (where the review has failed), only 'ONE' follow up CR shall be created which covers all findings of all Tasks of that CR (purpose: reduction of CRs).This must be agreed with the SwPM and the CR must be planned by SwPM.This CR must be spawned by the parent CR of the failed Task.Responsibility to provide the findings which shall be solved with another CR into the another CR belongs to the Owner of this Task. The reviewer should complete/close the Task only if the findings are documented in the follow up CR.Example how the follow-up CR might look:Summary: [FollowUp] <Summary_Of_CR_spawnedBy>Description:'This CR is a follow-up CR of <ID_of_CR_spawnedBy>.With this CR the findings shall be resolved, which were identified during the review of the Task(s) attached to the CR <ID_of_CR_spawnedBy>.It is agreed with SwPM to shift the correction of the findings to another build.Task: <ID of Task with Findings>Refer attachment 'ReviewFindingsOfTask_<ID of Task with Findings>'.', Conclusion: Brief analysis summary:22.04.2021Ashwini DigajerlaDig team:As per cluster ID 16 below DIDs has to be implemented.-Read ECU Name(c)-Read Supported configuration mechanisms(0xF131)-Read DID for Snapshot-Date: Vehicle Odometer in LowResolution(0x010A)-Read DID for Snapshot-Date: Current Operating Time(0x0133)Due to non availbility of the required interfaces for DID 0x010A and 0x0133 from Coms and FM subsytems ,seperate Spawn CR is created for implementing this 2 DIDs.Req Reference:Cdd file from D:\Daimbler\VariantSB\DiagMain\Cfg\Model Davini Configarator changes: ->Although all diagnostic jobs are already configured in the Dcm configuration, a Dcm configuration update will be required with this CR 4861342 .This is because:1. “Dsp Data Use Port” shall be changed to “USE_DATA_SYNCH_CLIENT_SERVER” As the callout will never return “pending”.->Task mapping for the RTE calls shall be done.Davini Developer changes: ->Create new runnables for 0xF101 and 0xF103 DIDs and generated DCM and RTE.Diag Application changes: Code Changes:-> Implement Read functions in DiagArAdapter_Cfg.c file->Add Read functions for 2 DIDs in the file \ReadDataByIdentifier_Cfg_Priv.h .-> In ReadDataByIdentifier_Cfg.c file add the call back functions in lookup table and implement functions to read the data.-> Add required macros to the corresponding ReadDataByIdentifier_Cfg.h. and ReadDataByIdentifier_Cfg_sub.h files.->only ROM data will be read with the 2 DIDs->Attached code changes.-> No actions required by MeMo,FM and coms team for this CR. 26.04.2021 WeyandC: Ooi Siang Tan has been removed from the list of analysers as MeMo team is not involved in this CR. Please, refer to the attached email "AW_ _DCRP 46_1_ _IBC__SW-D_ SF 8_8 System Diagnostic Function -Read ID-Data_ Remaining jobs_ Cluster ID 16.msg". Risk (low/medium/high): lowAnalysis completed by (applicable only for distributed analyses): Ashwini Digajerla . TASKTitle: [SWE1/4][Diag] SF 8.8 System Diagnostic Function Read ID-Data: Remaining jobs, Cluster ID 16Description:(SWE1) Please, provide Sw requirements for the customer requirements that specify diagnostic service: 0xF104,0xF131Link to customer requirements: http://skobde-doors9wa.ad.trw.com:8080/dwa/rm/urn:rational:e9aba799-bc96-11e5-b6b9-419012b199da:1-479f06bc41562230-M-0011ac00 Owner: Joachim HornungReviewer: Christian WeyandEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 4h[Optional] Planned completion date:TASKTitle: [SWE2/4][Diag] SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Description:(SWE2) Please update SwAD model according to derived requirements. The CR is used to implement diagnsotic service :0xF104,0xF131Please, note that SW requirements might not be available in time. In that case, it must be checked whether a follow-up CR needs to be created.Owner: Christian WeyandReviewer: Ahmed ElfekyEstimated design effort/h:Estimated implementation effort/h:Estimated unit testing effort/h:Total effort/h: 7h[Optional] Planned completion date: 30.04.2021 TASKTitle: [SWE3/4][Diag] SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Description:Implement Diag application part to support DIDs 0xF104 and 0xF131 . The task shall be used:1. to update the design model2. to implement the requested functionality including QAC, polyspace and log file analysis3. and to update / add VCast tests, execute them and link them to the design model. Details for point 2: The implementation in diagnostic application needs to be adapted with below new DIDs.-Read ECU Name(0xF104)-Read Supported configuration mechanisms(0xF131)Davini Configarator changes: ->Although all diagnostic jobs are already configured in the Dcm configuration, a Dcm configuration update will be required with this CR 4861342 .This is because:1. “Dsp Data Use Port” shall be changed to “USE_DATA_SYNCH_CLIENT_SERVER” As the callout will never return “pending”.->Task mapping for the RTE calls shall be done.Davini Developer changes: ->Create new runnables for 0xF101 and 0xF103 DIDs and generated DCM and RTE.Diag Application changes: Code Changes:-> Implement Read functions in DiagArAdapter_Cfg.c file->Add Read functions for 2 DIDs in the file \ReadDataByIdentifier_Cfg_Priv.h .-> In ReadDataByIdentifier_Cfg.c file add the call back functions in lookup table and implement functions to read the data.-> Add required macros to the corresponding ReadDataByIdentifier_Cfg.h. and ReadDataByIdentifier_Cfg_sub.h files.->only ROM data will be read with the 2 DIDs->Attached code changes.-> No actions required by MeMo,FM and coms team for this CR. Owner: Irannavar Satish Pundalik EXT HDR Tata ElxsiReviewer: Ashwini DigajerlaEstimated design effort/h:6Estimated implementation effort/h:6Estimated unit testing effort/h:18Total effort/h: 30h[Optional] Planned completion date: 30.04.2021 Task SwAD:Title:(SWE4/4)SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Description: Please import and map requirements.Owner:Caesar KlukowskiReviewer: Christoph Bayer, Christian WeyandTotal effort/h: 8[Optional] Planned completion date: 4.5.2021 Task AUTOSAR:Title:SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16Description:->With new Arxml provided by Diag task ,create new service ports and runnables for 0xF101 and 0xF103 DIDs .->Do task mapping for the new runnables in configarator . .->Generated DCM and RTE and checkin the changes.Owner: Sireesha BasavarajuReviewer: Hemanth Ambarukhana KrishnaTotal effort/h: 8[Optional] Planned completion date: 30.4.2021, LogType: Other
LogType: Other, Company: Daimler, Summary: [Defect]: [Diag] ESP178: ID-Data services not implemented
Provide the details for the given input
ID: 5533127, Summary: [VW][MQB48W][ESC][X0401-010_X330] ESP_StartStopp_Info = Systemfehler, State: ALM_Closed, Project: /BRK/Customer/VW/MQB48-W/ESC, Company: VW, Team: 2504646, Classification: Incident / Problem / Bug, Comments: [simo mannan kbl adwc54 (simom1), jul 28, 2021 3:35:45 pm cest][autosar & 3rd party sw ccb 2021-07-28] simom1: cr closed.[(system user) user for queue manager (scs_queuemanager), jul 28, 2021 2:15:58 pm cest]preintegration of 5541855 was successful. a checkpoint has been created on path #/brk#customer/vw/mqb48-w/esc/05_software/view_mainline/mmc_appl#d=iqm_preinteg_vw10_p03_m10_vtx_401_xxx_xxx_a. checkpoint number is 1.633.1.215.2.72.[(system user) user for queue manager (scs_queuemanager), jul 27, 2021 6:55:52 pm cest]preintegration of 5541855 was successful. a checkpoint has been created on path #/brk#customer/vw/mqb48-w/esc/05_software/view_mainline/mmc_appl#d=iqm_preinteg_vw10_p03_m10_vtx_401_xxx_xxx_a. checkpoint number is 1.633.1.215.2.71.[simo mannan kbl adwc54 (simom1), jul 26, 2021 6:08:37 pm cest][autosar & 3rd party sw ccb 2021-07-26] simom1: cr approved.[ujawane riya kbl adwc54 (ujawanr1), jul 26, 2021 10:03:19 am cest]cr assigned. proceed with the analysis., Description: Due to incorrect size of the ICC array "IccTxBuf_C1_C0.IsChassinfFunctionEnable_boolean" and the "for loop" shown below, Start/Stop function is always considered to be disabled by Chassinf (IsChassinfFunctionEnable(CHASSINF_SSA) always returns FALSE) even if the ECU is coded for Start/Stop and therefore, 'Systemfehler' is sent on the signal "ESP_StartStopp_Info" by the Start/Stop Handler. The issue is reported for X0401 SW as ICC is still used. In the later SW versions, ICC is replaced with RTE and this issue would not occur . The above fix therefore, is only required for X0401 SW., Conclusion: Brief analysis summary:This CR should be used for Regeneration of ICC to provide updated inter core communication wrapper for the rest of the software.Regeneration is required to resolve the issues due to incorrect size of ICC array 'IccTxBuf_C1_C0.IsChassinfFunctionEnable_boolean 'Correct array size is 152. Latest x401 CP : 1.633.1.215.2.68 should be used. Risk (low/medium/high): lowAnalysis completed by (applicable only for distributed analyses):Proposal of next steps (incl. effort/h and verification): Implement proposed task, LogType: Other
ID: 5533127
Provide the details for the given ID
ID: 5533127, Summary: [VW][MQB48W][ESC][X0401-010_X330] ESP_StartStopp_Info = Systemfehler, State: ALM_Closed, Project: /BRK/Customer/VW/MQB48-W/ESC, Company: VW, Team: 2504646, Classification: Incident / Problem / Bug, Comments: [simo mannan kbl adwc54 (simom1), jul 28, 2021 3:35:45 pm cest][autosar & 3rd party sw ccb 2021-07-28] simom1: cr closed.[(system user) user for queue manager (scs_queuemanager), jul 28, 2021 2:15:58 pm cest]preintegration of 5541855 was successful. a checkpoint has been created on path #/brk#customer/vw/mqb48-w/esc/05_software/view_mainline/mmc_appl#d=iqm_preinteg_vw10_p03_m10_vtx_401_xxx_xxx_a. checkpoint number is 1.633.1.215.2.72.[(system user) user for queue manager (scs_queuemanager), jul 27, 2021 6:55:52 pm cest]preintegration of 5541855 was successful. a checkpoint has been created on path #/brk#customer/vw/mqb48-w/esc/05_software/view_mainline/mmc_appl#d=iqm_preinteg_vw10_p03_m10_vtx_401_xxx_xxx_a. checkpoint number is 1.633.1.215.2.71.[simo mannan kbl adwc54 (simom1), jul 26, 2021 6:08:37 pm cest][autosar & 3rd party sw ccb 2021-07-26] simom1: cr approved.[ujawane riya kbl adwc54 (ujawanr1), jul 26, 2021 10:03:19 am cest]cr assigned. proceed with the analysis., Description: Due to incorrect size of the ICC array "IccTxBuf_C1_C0.IsChassinfFunctionEnable_boolean" and the "for loop" shown below, Start/Stop function is always considered to be disabled by Chassinf (IsChassinfFunctionEnable(CHASSINF_SSA) always returns FALSE) even if the ECU is coded for Start/Stop and therefore, 'Systemfehler' is sent on the signal "ESP_StartStopp_Info" by the Start/Stop Handler. The issue is reported for X0401 SW as ICC is still used. In the later SW versions, ICC is replaced with RTE and this issue would not occur . The above fix therefore, is only required for X0401 SW., Conclusion: Brief analysis summary:This CR should be used for Regeneration of ICC to provide updated inter core communication wrapper for the rest of the software.Regeneration is required to resolve the issues due to incorrect size of ICC array 'IccTxBuf_C1_C0.IsChassinfFunctionEnable_boolean 'Correct array size is 152. Latest x401 CP : 1.633.1.215.2.68 should be used. Risk (low/medium/high): lowAnalysis completed by (applicable only for distributed analyses):Proposal of next steps (incl. effort/h and verification): Implement proposed task, LogType: Other
Summary: [VW][MQB48W][ESC][X0401-010_X330] ESP_StartStopp_Info = Systemfehler
Provide the details for the given Summary
ID: 5533127, Summary: [VW][MQB48W][ESC][X0401-010_X330] ESP_StartStopp_Info = Systemfehler, State: ALM_Closed, Project: /BRK/Customer/VW/MQB48-W/ESC, Company: VW, Team: 2504646, Classification: Incident / Problem / Bug, Comments: [simo mannan kbl adwc54 (simom1), jul 28, 2021 3:35:45 pm cest][autosar & 3rd party sw ccb 2021-07-28] simom1: cr closed.[(system user) user for queue manager (scs_queuemanager), jul 28, 2021 2:15:58 pm cest]preintegration of 5541855 was successful. a checkpoint has been created on path #/brk#customer/vw/mqb48-w/esc/05_software/view_mainline/mmc_appl#d=iqm_preinteg_vw10_p03_m10_vtx_401_xxx_xxx_a. checkpoint number is 1.633.1.215.2.72.[(system user) user for queue manager (scs_queuemanager), jul 27, 2021 6:55:52 pm cest]preintegration of 5541855 was successful. a checkpoint has been created on path #/brk#customer/vw/mqb48-w/esc/05_software/view_mainline/mmc_appl#d=iqm_preinteg_vw10_p03_m10_vtx_401_xxx_xxx_a. checkpoint number is 1.633.1.215.2.71.[simo mannan kbl adwc54 (simom1), jul 26, 2021 6:08:37 pm cest][autosar & 3rd party sw ccb 2021-07-26] simom1: cr approved.[ujawane riya kbl adwc54 (ujawanr1), jul 26, 2021 10:03:19 am cest]cr assigned. proceed with the analysis., Description: Due to incorrect size of the ICC array "IccTxBuf_C1_C0.IsChassinfFunctionEnable_boolean" and the "for loop" shown below, Start/Stop function is always considered to be disabled by Chassinf (IsChassinfFunctionEnable(CHASSINF_SSA) always returns FALSE) even if the ECU is coded for Start/Stop and therefore, 'Systemfehler' is sent on the signal "ESP_StartStopp_Info" by the Start/Stop Handler. The issue is reported for X0401 SW as ICC is still used. In the later SW versions, ICC is replaced with RTE and this issue would not occur . The above fix therefore, is only required for X0401 SW., Conclusion: Brief analysis summary:This CR should be used for Regeneration of ICC to provide updated inter core communication wrapper for the rest of the software.Regeneration is required to resolve the issues due to incorrect size of ICC array 'IccTxBuf_C1_C0.IsChassinfFunctionEnable_boolean 'Correct array size is 152. Latest x401 CP : 1.633.1.215.2.68 should be used. Risk (low/medium/high): lowAnalysis completed by (applicable only for distributed analyses):Proposal of next steps (incl. effort/h and verification): Implement proposed task, LogType: Other
LogType: Other, Company: VW, Summary: [VW][MQB48W][ESC][X0401-010_X330] ESP_StartStopp_Info = Systemfehler
Provide the details for the given input
ID: 5533486, Summary: Customer Request: parameter set in new format: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC", State: ALM_Checked, Project: /EPB/CustomerDevelopment/Audi/CBEV, Company: CustomerDevelopment, Team: 1872073, Classification: Requirements, Comments: [gerz michael kbl adby212 (wyrthm), aug 11, 2021 11:51:44 am cest]f&c ccb - mg - 11.08.2021 - 11:51cr closed., Description: Realization of Customer request: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC" target is to provide the recent Parameterset (series software S011) in a new format for new Software S012: CRs shall be created for following tasks F&C: *. update minor Revision of recent Parameter set “PARAMPBL_Audi_CBEV_039_056_000.c” 0G à 0H à new Parameter set(Integration: *. creating of new ODX file with the name: “DB_0003_7101_4KE_A00H_AU516PBCA00H_M3PBCVAR001ECE18HA.odx” *. using new ODX create (v2.50): url:integrity://skobde-mks.kobde.trw.com:7001/si/viewhistory?project=/EPB/CustomerDevelopment/Audi/CBEV/01%5fFrom%5fCustomer/03%5fTools/ODXCreate/project.pj&selection=%22ODXCreate%5fV250%5fLizenz%5f20221205.7z%22 *. with new FDS2309: url:integrity://skobde-mks.kobde.trw.com:7001/si/viewhistory?project=/EPB/CustomerDevelopment/Audi/CBEV/01%5fFrom%5fCustomer/03%5fTools/ODXCreate/project.pj&selection=%22config%5fFDSProject%5f2309%5fE.7z%22 *. and possibly (depending on answer of Conti): new SA2 code (to be provided by Continental) *. Preparation of Zip file using Audi Tool: url:integrity://skobde-mks.kobde.trw.com:7001/si/viewhistory?project=/EPB/CustomerDevelopment/Audi/PPE/01%5fFrom%5fCustomer/03%5fTools/ODX/project.pj&selection=%22dsdg22sys42%5fwithout%5fprefix.zip%22 ) This Change Request shall be used to for PBC Function & Control Team - change in parameter set, Conclusion: P. Billig (23.07.21 - 14:10):Brief investigation comment:This CR is for adapting some revision numbers and generating the new PARAMPBL_*.c file only (F&C part, see above). To do so: - Adapt minor revision of parameter file as usual. Do NOT generate parameter files yet.- In file PBC_PARA\03_Integration\Build_Param\Config\DB_0003_7101_4KE_A001_AU5160000000_AU5164KESW0001DSA001.ocnf adapt values <DataRecordVersion>A00G</DataRecordVersion><ModulVariant>AU516PBCA00G</ModulVariant> to <DataRecordVersion>A00H</DataRecordVersion><ModulVariant>AU516PBCA00H</ModulVariant> - Update PBC_PARA\03_Integration\Build_Param\Build module to checkpoint 1.14.1.9.1.3- Now generate new parameter files.- If not present, check in generated PARAMPBL_*.c file- If an older PARAMPBL_*.c is present at the same folder with a different name, remove it.- Check in other parameter file generation artifacts, as usual. Risk (low/medium/high): mediumProposal of next steps (incl. effort / h and verifier):- One task for TCI: <Title> Audi CBEV - Adapt some parameter file revision numbers and generate new parameter files / Verifier: E. Harder (8 h) Is a change in the ParameterFile required? (Do we need a PARA build?)Yes [x] or No [] Function & Control CCB - FZI - 22.07.21 - 13:40:Please investigate this point and advise the next steps., LogType: Other
ID: 5533486
Provide the details for the given ID
ID: 5533486, Summary: Customer Request: parameter set in new format: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC", State: ALM_Checked, Project: /EPB/CustomerDevelopment/Audi/CBEV, Company: CustomerDevelopment, Team: 1872073, Classification: Requirements, Comments: [gerz michael kbl adby212 (wyrthm), aug 11, 2021 11:51:44 am cest]f&c ccb - mg - 11.08.2021 - 11:51cr closed., Description: Realization of Customer request: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC" target is to provide the recent Parameterset (series software S011) in a new format for new Software S012: CRs shall be created for following tasks F&C: *. update minor Revision of recent Parameter set “PARAMPBL_Audi_CBEV_039_056_000.c” 0G à 0H à new Parameter set(Integration: *. creating of new ODX file with the name: “DB_0003_7101_4KE_A00H_AU516PBCA00H_M3PBCVAR001ECE18HA.odx” *. using new ODX create (v2.50): url:integrity://skobde-mks.kobde.trw.com:7001/si/viewhistory?project=/EPB/CustomerDevelopment/Audi/CBEV/01%5fFrom%5fCustomer/03%5fTools/ODXCreate/project.pj&selection=%22ODXCreate%5fV250%5fLizenz%5f20221205.7z%22 *. with new FDS2309: url:integrity://skobde-mks.kobde.trw.com:7001/si/viewhistory?project=/EPB/CustomerDevelopment/Audi/CBEV/01%5fFrom%5fCustomer/03%5fTools/ODXCreate/project.pj&selection=%22config%5fFDSProject%5f2309%5fE.7z%22 *. and possibly (depending on answer of Conti): new SA2 code (to be provided by Continental) *. Preparation of Zip file using Audi Tool: url:integrity://skobde-mks.kobde.trw.com:7001/si/viewhistory?project=/EPB/CustomerDevelopment/Audi/PPE/01%5fFrom%5fCustomer/03%5fTools/ODX/project.pj&selection=%22dsdg22sys42%5fwithout%5fprefix.zip%22 ) This Change Request shall be used to for PBC Function & Control Team - change in parameter set, Conclusion: P. Billig (23.07.21 - 14:10):Brief investigation comment:This CR is for adapting some revision numbers and generating the new PARAMPBL_*.c file only (F&C part, see above). To do so: - Adapt minor revision of parameter file as usual. Do NOT generate parameter files yet.- In file PBC_PARA\03_Integration\Build_Param\Config\DB_0003_7101_4KE_A001_AU5160000000_AU5164KESW0001DSA001.ocnf adapt values <DataRecordVersion>A00G</DataRecordVersion><ModulVariant>AU516PBCA00G</ModulVariant> to <DataRecordVersion>A00H</DataRecordVersion><ModulVariant>AU516PBCA00H</ModulVariant> - Update PBC_PARA\03_Integration\Build_Param\Build module to checkpoint 1.14.1.9.1.3- Now generate new parameter files.- If not present, check in generated PARAMPBL_*.c file- If an older PARAMPBL_*.c is present at the same folder with a different name, remove it.- Check in other parameter file generation artifacts, as usual. Risk (low/medium/high): mediumProposal of next steps (incl. effort / h and verifier):- One task for TCI: <Title> Audi CBEV - Adapt some parameter file revision numbers and generate new parameter files / Verifier: E. Harder (8 h) Is a change in the ParameterFile required? (Do we need a PARA build?)Yes [x] or No [] Function & Control CCB - FZI - 22.07.21 - 13:40:Please investigate this point and advise the next steps., LogType: Other
Summary: Customer Request: parameter set in new format: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC"
Provide the details for the given Summary
ID: 5533486, Summary: Customer Request: parameter set in new format: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC", State: ALM_Checked, Project: /EPB/CustomerDevelopment/Audi/CBEV, Company: CustomerDevelopment, Team: 1872073, Classification: Requirements, Comments: [gerz michael kbl adby212 (wyrthm), aug 11, 2021 11:51:44 am cest]f&c ccb - mg - 11.08.2021 - 11:51cr closed., Description: Realization of Customer request: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC" target is to provide the recent Parameterset (series software S011) in a new format for new Software S012: CRs shall be created for following tasks F&C: *. update minor Revision of recent Parameter set “PARAMPBL_Audi_CBEV_039_056_000.c” 0G à 0H à new Parameter set(Integration: *. creating of new ODX file with the name: “DB_0003_7101_4KE_A00H_AU516PBCA00H_M3PBCVAR001ECE18HA.odx” *. using new ODX create (v2.50): url:integrity://skobde-mks.kobde.trw.com:7001/si/viewhistory?project=/EPB/CustomerDevelopment/Audi/CBEV/01%5fFrom%5fCustomer/03%5fTools/ODXCreate/project.pj&selection=%22ODXCreate%5fV250%5fLizenz%5f20221205.7z%22 *. with new FDS2309: url:integrity://skobde-mks.kobde.trw.com:7001/si/viewhistory?project=/EPB/CustomerDevelopment/Audi/CBEV/01%5fFrom%5fCustomer/03%5fTools/ODXCreate/project.pj&selection=%22config%5fFDSProject%5f2309%5fE.7z%22 *. and possibly (depending on answer of Conti): new SA2 code (to be provided by Continental) *. Preparation of Zip file using Audi Tool: url:integrity://skobde-mks.kobde.trw.com:7001/si/viewhistory?project=/EPB/CustomerDevelopment/Audi/PPE/01%5fFrom%5fCustomer/03%5fTools/ODX/project.pj&selection=%22dsdg22sys42%5fwithout%5fprefix.zip%22 ) This Change Request shall be used to for PBC Function & Control Team - change in parameter set, Conclusion: P. Billig (23.07.21 - 14:10):Brief investigation comment:This CR is for adapting some revision numbers and generating the new PARAMPBL_*.c file only (F&C part, see above). To do so: - Adapt minor revision of parameter file as usual. Do NOT generate parameter files yet.- In file PBC_PARA\03_Integration\Build_Param\Config\DB_0003_7101_4KE_A001_AU5160000000_AU5164KESW0001DSA001.ocnf adapt values <DataRecordVersion>A00G</DataRecordVersion><ModulVariant>AU516PBCA00G</ModulVariant> to <DataRecordVersion>A00H</DataRecordVersion><ModulVariant>AU516PBCA00H</ModulVariant> - Update PBC_PARA\03_Integration\Build_Param\Build module to checkpoint 1.14.1.9.1.3- Now generate new parameter files.- If not present, check in generated PARAMPBL_*.c file- If an older PARAMPBL_*.c is present at the same folder with a different name, remove it.- Check in other parameter file generation artifacts, as usual. Risk (low/medium/high): mediumProposal of next steps (incl. effort / h and verifier):- One task for TCI: <Title> Audi CBEV - Adapt some parameter file revision numbers and generate new parameter files / Verifier: E. Harder (8 h) Is a change in the ParameterFile required? (Do we need a PARA build?)Yes [x] or No [] Function & Control CCB - FZI - 22.07.21 - 13:40:Please investigate this point and advise the next steps., LogType: Other
LogType: Other, Company: CustomerDevelopment, Summary: Customer Request: parameter set in new format: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC"
Provide the details for the given input
ID: 5533541, Summary: [QRCM] GM T1XX - Motor Position Sensor (MPS) Failure to Learn, State: ALM_Rejected, Project: /BrkEngEQFS/EngineeringQuality, Company: EngineeringQuality, Team: , Classification: Quality, Comments: , Description: "systematic root-cause" should be documented in 3x5 Why, and an improvement idea should be proposed.This CR is to track the implementation of the systematic improvement, Conclusion: Reject this CR for Preventive Action. SW can handle any specified range of error adjustment. 2% was specificed by Systems group., LogType: Other
ID: 5533541
Provide the details for the given ID
ID: 5533541, Summary: [QRCM] GM T1XX - Motor Position Sensor (MPS) Failure to Learn, State: ALM_Rejected, Project: /BrkEngEQFS/EngineeringQuality, Company: EngineeringQuality, Team: , Classification: Quality, Comments: , Description: "systematic root-cause" should be documented in 3x5 Why, and an improvement idea should be proposed.This CR is to track the implementation of the systematic improvement, Conclusion: Reject this CR for Preventive Action. SW can handle any specified range of error adjustment. 2% was specificed by Systems group., LogType: Other
Summary: [QRCM] GM T1XX - Motor Position Sensor (MPS) Failure to Learn
Provide the details for the given Summary
ID: 5533541, Summary: [QRCM] GM T1XX - Motor Position Sensor (MPS) Failure to Learn, State: ALM_Rejected, Project: /BrkEngEQFS/EngineeringQuality, Company: EngineeringQuality, Team: , Classification: Quality, Comments: , Description: "systematic root-cause" should be documented in 3x5 Why, and an improvement idea should be proposed.This CR is to track the implementation of the systematic improvement, Conclusion: Reject this CR for Preventive Action. SW can handle any specified range of error adjustment. 2% was specificed by Systems group., LogType: Other
LogType: Other, Company: EngineeringQuality, Summary: [QRCM] GM T1XX - Motor Position Sensor (MPS) Failure to Learn
Provide the details for the given input
ID: 5461318, Summary: [QA][PA2116][SYS.4][GP.2.1.2][GP.2.1.3][GP.2.1.4][SYS.5][GP.2.1.2][GP.2.1.3]Only Duration estimation mentioned in the MS project plan but not the effort (person days), State: ALM_Closed, Project: /Steering/Projects/Geely/Lotus_EPA/PR55729_LVS_ENG_APP_Geely_Lotus_EPA_EPS_BD_SYS_HRoom_AP, Company: Geely, Team: 4247386, Classification: Quality, Comments: , Description: Update MS Project information according to mentioned points., Conclusion: Update MS project information according to the weekness that ASPICE mentioned., LogType: Other
ID: 5461318
Provide the details for the given ID
ID: 5461318, Summary: [QA][PA2116][SYS.4][GP.2.1.2][GP.2.1.3][GP.2.1.4][SYS.5][GP.2.1.2][GP.2.1.3]Only Duration estimation mentioned in the MS project plan but not the effort (person days), State: ALM_Closed, Project: /Steering/Projects/Geely/Lotus_EPA/PR55729_LVS_ENG_APP_Geely_Lotus_EPA_EPS_BD_SYS_HRoom_AP, Company: Geely, Team: 4247386, Classification: Quality, Comments: , Description: Update MS Project information according to mentioned points., Conclusion: Update MS project information according to the weekness that ASPICE mentioned., LogType: Other
Summary: [QA][PA2116][SYS.4][GP.2.1.2][GP.2.1.3][GP.2.1.4][SYS.5][GP.2.1.2][GP.2.1.3]Only Duration estimation mentioned in the MS project plan but not the effort (person days)
Provide the details for the given Summary
ID: 5461318, Summary: [QA][PA2116][SYS.4][GP.2.1.2][GP.2.1.3][GP.2.1.4][SYS.5][GP.2.1.2][GP.2.1.3]Only Duration estimation mentioned in the MS project plan but not the effort (person days), State: ALM_Closed, Project: /Steering/Projects/Geely/Lotus_EPA/PR55729_LVS_ENG_APP_Geely_Lotus_EPA_EPS_BD_SYS_HRoom_AP, Company: Geely, Team: 4247386, Classification: Quality, Comments: , Description: Update MS Project information according to mentioned points., Conclusion: Update MS project information according to the weekness that ASPICE mentioned., LogType: Other
LogType: Other, Company: Geely, Summary: [QA][PA2116][SYS.4][GP.2.1.2][GP.2.1.3][GP.2.1.4][SYS.5][GP.2.1.2][GP.2.1.3]Only Duration estimation mentioned in the MS project plan but not the effort (person days)
Provide the details for the given input
ID: 5533620, Summary: Integration OP A100/BEV3 PBM - Remove Ground Disconnected Faults, State: ALM_Closed, Project: /IBC/Customer/GM/A100, Company: GM, Team: 2612757, Classification: Requirements, Comments: , Description: The goal of this CR is to disable/remove Ground monitor failsafes from A100 PBM, A100 SBM and 31XX.2 programs., Conclusion: Andrew Berg 07-21-21 Proposed_Changes_v2.zip attached.QAC Report v2.zip attached.Test Report v2.docx attached. Andrew Berg 07-14-21 Proposed_Changes_v1.zip attached.QAC Report v1.zip attached., LogType: Fault Detection Log
ID: 5533620
Provide the details for the given ID
ID: 5533620, Summary: Integration OP A100/BEV3 PBM - Remove Ground Disconnected Faults, State: ALM_Closed, Project: /IBC/Customer/GM/A100, Company: GM, Team: 2612757, Classification: Requirements, Comments: , Description: The goal of this CR is to disable/remove Ground monitor failsafes from A100 PBM, A100 SBM and 31XX.2 programs., Conclusion: Andrew Berg 07-21-21 Proposed_Changes_v2.zip attached.QAC Report v2.zip attached.Test Report v2.docx attached. Andrew Berg 07-14-21 Proposed_Changes_v1.zip attached.QAC Report v1.zip attached., LogType: Fault Detection Log
Summary: Integration OP A100/BEV3 PBM - Remove Ground Disconnected Faults
Provide the details for the given Summary
ID: 5533620, Summary: Integration OP A100/BEV3 PBM - Remove Ground Disconnected Faults, State: ALM_Closed, Project: /IBC/Customer/GM/A100, Company: GM, Team: 2612757, Classification: Requirements, Comments: , Description: The goal of this CR is to disable/remove Ground monitor failsafes from A100 PBM, A100 SBM and 31XX.2 programs., Conclusion: Andrew Berg 07-21-21 Proposed_Changes_v2.zip attached.QAC Report v2.zip attached.Test Report v2.docx attached. Andrew Berg 07-14-21 Proposed_Changes_v1.zip attached.QAC Report v1.zip attached., LogType: Fault Detection Log
LogType: Fault Detection Log, Company: GM, Summary: Integration OP A100/BEV3 PBM - Remove Ground Disconnected Faults
Provide the details for the given input
ID: 5533633, Summary: Integration OP A100/BEV3 SBM - Remove Ground Disconnected Faults, State: ALM_Closed, Project: /IBC/Customer/GM/A100, Company: GM, Team: 2612757, Classification: Requirements, Comments: , Description: The goal of this CR is to disable/remove Ground monitor failsafes from A100 PBM, A100 SBM and 31XX.2 programs., Conclusion: Andrew Berg 07-21-21 Proposed_Changes_v2.zip attached.QAC Report v2.zip attached.Test Report v2.docx attached. Andrew Berg 07-14-21 Proposed_Changes_v1.zip attached.QAC Report v1.zip attached., LogType: Fault Detection Log
ID: 5533633
Provide the details for the given ID
ID: 5533633, Summary: Integration OP A100/BEV3 SBM - Remove Ground Disconnected Faults, State: ALM_Closed, Project: /IBC/Customer/GM/A100, Company: GM, Team: 2612757, Classification: Requirements, Comments: , Description: The goal of this CR is to disable/remove Ground monitor failsafes from A100 PBM, A100 SBM and 31XX.2 programs., Conclusion: Andrew Berg 07-21-21 Proposed_Changes_v2.zip attached.QAC Report v2.zip attached.Test Report v2.docx attached. Andrew Berg 07-14-21 Proposed_Changes_v1.zip attached.QAC Report v1.zip attached., LogType: Fault Detection Log
Summary: Integration OP A100/BEV3 SBM - Remove Ground Disconnected Faults
Provide the details for the given Summary
ID: 5533633, Summary: Integration OP A100/BEV3 SBM - Remove Ground Disconnected Faults, State: ALM_Closed, Project: /IBC/Customer/GM/A100, Company: GM, Team: 2612757, Classification: Requirements, Comments: , Description: The goal of this CR is to disable/remove Ground monitor failsafes from A100 PBM, A100 SBM and 31XX.2 programs., Conclusion: Andrew Berg 07-21-21 Proposed_Changes_v2.zip attached.QAC Report v2.zip attached.Test Report v2.docx attached. Andrew Berg 07-14-21 Proposed_Changes_v1.zip attached.QAC Report v1.zip attached., LogType: Fault Detection Log
LogType: Fault Detection Log, Company: GM, Summary: Integration OP A100/BEV3 SBM - Remove Ground Disconnected Faults
Provide the details for the given input
ID: 5461337, Summary: [OPEL K0][X300_173][CAT2][ADTY3][TEC]: UNEXPECTED_EXCEPTION - fault is seen unexpected, State: ALM_Closed, Project: /SCS/Customer/PSA/K0, Company: PSA, Team: 3544059, Classification: Incident / Problem / Bug, Comments: [karthik kamasamudram (z0016377), jul 6, 2021 6:01:30 am cest]closed by swpm[(system user) user for queue manager (scs_queuemanager), jul 2, 2021 2:38:54 pm cest]preintegration of 5472204 was successful. a checkpoint has been created on path #/scs#customer/psa/opel_x250/05_software/view_mainline/mmc_appl#d=preintegration_opel_x250. checkpoint number is 1.2.1.372., Description: SW-Resets due to exceptions in Opel-K0 project and below change was introduced with “ALM_Task 5202634: [OPEL K0] [PSW] Proivde interfaces for Tx signals” where the dataset are not aligned to group ID ordering of CAL sub groups. But addition of new Calibration set for AAW does not match to the group ordering,, Conclusion: The group ordering for the AAW calibration set must be changed, LogType: Fault Detection Log
ID: 5461337
Provide the details for the given ID
ID: 5461337, Summary: [OPEL K0][X300_173][CAT2][ADTY3][TEC]: UNEXPECTED_EXCEPTION - fault is seen unexpected, State: ALM_Closed, Project: /SCS/Customer/PSA/K0, Company: PSA, Team: 3544059, Classification: Incident / Problem / Bug, Comments: [karthik kamasamudram (z0016377), jul 6, 2021 6:01:30 am cest]closed by swpm[(system user) user for queue manager (scs_queuemanager), jul 2, 2021 2:38:54 pm cest]preintegration of 5472204 was successful. a checkpoint has been created on path #/scs#customer/psa/opel_x250/05_software/view_mainline/mmc_appl#d=preintegration_opel_x250. checkpoint number is 1.2.1.372., Description: SW-Resets due to exceptions in Opel-K0 project and below change was introduced with “ALM_Task 5202634: [OPEL K0] [PSW] Proivde interfaces for Tx signals” where the dataset are not aligned to group ID ordering of CAL sub groups. But addition of new Calibration set for AAW does not match to the group ordering,, Conclusion: The group ordering for the AAW calibration set must be changed, LogType: Fault Detection Log
Summary: [OPEL K0][X300_173][CAT2][ADTY3][TEC]: UNEXPECTED_EXCEPTION - fault is seen unexpected
Provide the details for the given Summary
ID: 5461337, Summary: [OPEL K0][X300_173][CAT2][ADTY3][TEC]: UNEXPECTED_EXCEPTION - fault is seen unexpected, State: ALM_Closed, Project: /SCS/Customer/PSA/K0, Company: PSA, Team: 3544059, Classification: Incident / Problem / Bug, Comments: [karthik kamasamudram (z0016377), jul 6, 2021 6:01:30 am cest]closed by swpm[(system user) user for queue manager (scs_queuemanager), jul 2, 2021 2:38:54 pm cest]preintegration of 5472204 was successful. a checkpoint has been created on path #/scs#customer/psa/opel_x250/05_software/view_mainline/mmc_appl#d=preintegration_opel_x250. checkpoint number is 1.2.1.372., Description: SW-Resets due to exceptions in Opel-K0 project and below change was introduced with “ALM_Task 5202634: [OPEL K0] [PSW] Proivde interfaces for Tx signals” where the dataset are not aligned to group ID ordering of CAL sub groups. But addition of new Calibration set for AAW does not match to the group ordering,, Conclusion: The group ordering for the AAW calibration set must be changed, LogType: Fault Detection Log
LogType: Fault Detection Log, Company: PSA, Summary: [OPEL K0][X300_173][CAT2][ADTY3][TEC]: UNEXPECTED_EXCEPTION - fault is seen unexpected
Provide the details for the given input
ID: 5533777, Summary: [xxxxxxx] [NA] GM T1XX - MEC counter corrupted during EOL test (NVRAM), State: ALM_Defined, Project: /BrkEngEQFS/EngineeringQuality, Company: EngineeringQuality, Team: 3383777, Classification: Incident / Problem / Bug, Comments: [hollingsworth mark lvn aqdb3 (z0053591), sep 20, 2021 10:56:45 pm cest]comment below is a mix-up. this issue is not for steven helinski.this topic is within nvram (memo-team) stephan scheider from my team ( alfter ingo dr. kbl adwc) will support here, he is vacation and will be back 4th october.?but i still can't assign correct owner to this cr. [hollingsworth mark lvn aqdb3 (z0053591), aug 31, 2021 2:55:58 pm cest] - not able to add the correct owner, steve helinski (aka helinski steven lvn adwn21 <steven.helinski@zf.com>), probably because of the project this cr is in., Description: - This CR is to track the improvement from 3x5Why “systemic leg” Root cause: Data owner and memory stack service provider are not aligned. ? Per Stephan Scheider, the process is mature for IBC Gen2 core projects, so called “NVRAM Contracts” in DOORs for each data block. Data owners select appropriate failure correction option for memory stack service provider to implement. This concept should be investigated - then next steps defined for potential roll-out in North America projects, Conclusion: Meeting Minutes: Oct-5Participants: Mark Hollingsworth, Stephan Scheider Discussion:Memory stack is a service provider which must contract with datablock owners and implement according to datablock owner request.Datablock owners must understand impact of NVRAM failures on their data, and select appropriate failure correction option. The process is mature as explaind for IBC Gen2 core project:There are NVRAM contracts in DOORS for each datablock.The contracts formarlizes key points:1) who is datablock owner2) what are requirements for datablock protection The process is informally handled in most existing projects. Someone in project knows NVRAM and should know data owner counterparts. Possible improvement is to develop a interview style guidance/questionnaire for datablock owners which is similar to the DOORs contract.Stephan suggest I contact Mel in ADWC2 to see if he can support., LogType: Other
ID: 5533777
Provide the details for the given ID
ID: 5533777, Summary: [xxxxxxx] [NA] GM T1XX - MEC counter corrupted during EOL test (NVRAM), State: ALM_Defined, Project: /BrkEngEQFS/EngineeringQuality, Company: EngineeringQuality, Team: 3383777, Classification: Incident / Problem / Bug, Comments: [hollingsworth mark lvn aqdb3 (z0053591), sep 20, 2021 10:56:45 pm cest]comment below is a mix-up. this issue is not for steven helinski.this topic is within nvram (memo-team) stephan scheider from my team ( alfter ingo dr. kbl adwc) will support here, he is vacation and will be back 4th october.?but i still can't assign correct owner to this cr. [hollingsworth mark lvn aqdb3 (z0053591), aug 31, 2021 2:55:58 pm cest] - not able to add the correct owner, steve helinski (aka helinski steven lvn adwn21 <steven.helinski@zf.com>), probably because of the project this cr is in., Description: - This CR is to track the improvement from 3x5Why “systemic leg” Root cause: Data owner and memory stack service provider are not aligned. ? Per Stephan Scheider, the process is mature for IBC Gen2 core projects, so called “NVRAM Contracts” in DOORs for each data block. Data owners select appropriate failure correction option for memory stack service provider to implement. This concept should be investigated - then next steps defined for potential roll-out in North America projects, Conclusion: Meeting Minutes: Oct-5Participants: Mark Hollingsworth, Stephan Scheider Discussion:Memory stack is a service provider which must contract with datablock owners and implement according to datablock owner request.Datablock owners must understand impact of NVRAM failures on their data, and select appropriate failure correction option. The process is mature as explaind for IBC Gen2 core project:There are NVRAM contracts in DOORS for each datablock.The contracts formarlizes key points:1) who is datablock owner2) what are requirements for datablock protection The process is informally handled in most existing projects. Someone in project knows NVRAM and should know data owner counterparts. Possible improvement is to develop a interview style guidance/questionnaire for datablock owners which is similar to the DOORs contract.Stephan suggest I contact Mel in ADWC2 to see if he can support., LogType: Other
Summary: [xxxxxxx] [NA] GM T1XX - MEC counter corrupted during EOL test (NVRAM)
Provide the details for the given Summary
ID: 5533777, Summary: [xxxxxxx] [NA] GM T1XX - MEC counter corrupted during EOL test (NVRAM), State: ALM_Defined, Project: /BrkEngEQFS/EngineeringQuality, Company: EngineeringQuality, Team: 3383777, Classification: Incident / Problem / Bug, Comments: [hollingsworth mark lvn aqdb3 (z0053591), sep 20, 2021 10:56:45 pm cest]comment below is a mix-up. this issue is not for steven helinski.this topic is within nvram (memo-team) stephan scheider from my team ( alfter ingo dr. kbl adwc) will support here, he is vacation and will be back 4th october.?but i still can't assign correct owner to this cr. [hollingsworth mark lvn aqdb3 (z0053591), aug 31, 2021 2:55:58 pm cest] - not able to add the correct owner, steve helinski (aka helinski steven lvn adwn21 <steven.helinski@zf.com>), probably because of the project this cr is in., Description: - This CR is to track the improvement from 3x5Why “systemic leg” Root cause: Data owner and memory stack service provider are not aligned. ? Per Stephan Scheider, the process is mature for IBC Gen2 core projects, so called “NVRAM Contracts” in DOORs for each data block. Data owners select appropriate failure correction option for memory stack service provider to implement. This concept should be investigated - then next steps defined for potential roll-out in North America projects, Conclusion: Meeting Minutes: Oct-5Participants: Mark Hollingsworth, Stephan Scheider Discussion:Memory stack is a service provider which must contract with datablock owners and implement according to datablock owner request.Datablock owners must understand impact of NVRAM failures on their data, and select appropriate failure correction option. The process is mature as explaind for IBC Gen2 core project:There are NVRAM contracts in DOORS for each datablock.The contracts formarlizes key points:1) who is datablock owner2) what are requirements for datablock protection The process is informally handled in most existing projects. Someone in project knows NVRAM and should know data owner counterparts. Possible improvement is to develop a interview style guidance/questionnaire for datablock owners which is similar to the DOORs contract.Stephan suggest I contact Mel in ADWC2 to see if he can support., LogType: Other
LogType: Other, Company: EngineeringQuality, Summary: [xxxxxxx] [NA] GM T1XX - MEC counter corrupted during EOL test (NVRAM)
Provide the details for the given input
ID: 5533814, Summary: 18A incorrect in ESLM data package, State: ALM_Closed, Project: /Steering/Projects/FCA-FIAT/MP/PR55906_LVS_ENG_APP_FCA_598_EPS_CD_SYS_HRoom_NA, Company: FCA-FIAT, Team: 4038904, Classification: Incident / Problem / Bug, Comments: , Description: , Conclusion: One task for PXX team to implement the fix 2021-08-04 StolarsK: Fix was implemented. CR can be closed., LogType: Other
ID: 5533814
Provide the details for the given ID
ID: 5533814, Summary: 18A incorrect in ESLM data package, State: ALM_Closed, Project: /Steering/Projects/FCA-FIAT/MP/PR55906_LVS_ENG_APP_FCA_598_EPS_CD_SYS_HRoom_NA, Company: FCA-FIAT, Team: 4038904, Classification: Incident / Problem / Bug, Comments: , Description: , Conclusion: One task for PXX team to implement the fix 2021-08-04 StolarsK: Fix was implemented. CR can be closed., LogType: Other
Summary: 18A incorrect in ESLM data package
Provide the details for the given Summary
ID: 5533814, Summary: 18A incorrect in ESLM data package, State: ALM_Closed, Project: /Steering/Projects/FCA-FIAT/MP/PR55906_LVS_ENG_APP_FCA_598_EPS_CD_SYS_HRoom_NA, Company: FCA-FIAT, Team: 4038904, Classification: Incident / Problem / Bug, Comments: , Description: , Conclusion: One task for PXX team to implement the fix 2021-08-04 StolarsK: Fix was implemented. CR can be closed., LogType: Other
LogType: Other, Company: FCA-FIAT, Summary: 18A incorrect in ESLM data package
Provide the details for the given input
ID: 5461871, Summary: [QA][WPA][PV03][S110-S120] System Baseline Work product to be released_ReAX, State: ALM_Closed, Project: /Steering/Projects/ZF/ReAx/PR47704_Core_ZF_ReAx_EPP, Company: ZF, Team: 2294505, Classification: Quality, Comments: [singh rajinder ext ext (singhr9), sep 29, 2021 4:05:42 pm cest]task for s150/s200 c40 checklist has been moved to pv03 master cr4767460, Description: Due to Resource constraints TSC and System Baseline updates could not be supported at the respective S Gates originally planned. Agreed that these items should be re-planned to align with S200 (Depending allocation of Resource). It was noted that System Baseline should not be expected to be delivered at S120 as this requires full confirmation of the TSC attributes and this can not be achieved at this early stage of a project. This CR has been created specifically to cover following SE/PIL activities: WPr#55 - TSC Baseline and confirmation [Defered from S120]. Refer to original S120 ALM_Task 5406385. WPr#31 - System Baseline [Deferred from S120 as can not be completed until TSC has been reviewed and attributes set]. Refer to original S110 ALM_Task 5405979 . In addition to above PM to raise Action related to: With Quality consent; update the PV03 WPP to record re-planning of these work products. In addition raise Clarity Risk against the Resource constraints for the PIL/SE role. Identify on the associated Tasks the target dates for the re-planned Work Products., Conclusion: *2021-10-05 SINGHR9 *Related Tasks have been completed and Work Products Delivered. S200 to be run and checklist is managed separate to this CR. *2021-07-07 SINGHR9 Re-plan of key Work Products documented in related ALM_Action 5481501. Proceed to create tasks for S200 for: WPr#55 - TSC Baseline and confirmation WPr#31 - System Baseline, LogType: Other
ID: 5461871
Provide the details for the given ID
ID: 5461871, Summary: [QA][WPA][PV03][S110-S120] System Baseline Work product to be released_ReAX, State: ALM_Closed, Project: /Steering/Projects/ZF/ReAx/PR47704_Core_ZF_ReAx_EPP, Company: ZF, Team: 2294505, Classification: Quality, Comments: [singh rajinder ext ext (singhr9), sep 29, 2021 4:05:42 pm cest]task for s150/s200 c40 checklist has been moved to pv03 master cr4767460, Description: Due to Resource constraints TSC and System Baseline updates could not be supported at the respective S Gates originally planned. Agreed that these items should be re-planned to align with S200 (Depending allocation of Resource). It was noted that System Baseline should not be expected to be delivered at S120 as this requires full confirmation of the TSC attributes and this can not be achieved at this early stage of a project. This CR has been created specifically to cover following SE/PIL activities: WPr#55 - TSC Baseline and confirmation [Defered from S120]. Refer to original S120 ALM_Task 5406385. WPr#31 - System Baseline [Deferred from S120 as can not be completed until TSC has been reviewed and attributes set]. Refer to original S110 ALM_Task 5405979 . In addition to above PM to raise Action related to: With Quality consent; update the PV03 WPP to record re-planning of these work products. In addition raise Clarity Risk against the Resource constraints for the PIL/SE role. Identify on the associated Tasks the target dates for the re-planned Work Products., Conclusion: *2021-10-05 SINGHR9 *Related Tasks have been completed and Work Products Delivered. S200 to be run and checklist is managed separate to this CR. *2021-07-07 SINGHR9 Re-plan of key Work Products documented in related ALM_Action 5481501. Proceed to create tasks for S200 for: WPr#55 - TSC Baseline and confirmation WPr#31 - System Baseline, LogType: Other
Summary: [QA][WPA][PV03][S110-S120] System Baseline Work product to be released_ReAX
Provide the details for the given Summary
ID: 5461871, Summary: [QA][WPA][PV03][S110-S120] System Baseline Work product to be released_ReAX, State: ALM_Closed, Project: /Steering/Projects/ZF/ReAx/PR47704_Core_ZF_ReAx_EPP, Company: ZF, Team: 2294505, Classification: Quality, Comments: [singh rajinder ext ext (singhr9), sep 29, 2021 4:05:42 pm cest]task for s150/s200 c40 checklist has been moved to pv03 master cr4767460, Description: Due to Resource constraints TSC and System Baseline updates could not be supported at the respective S Gates originally planned. Agreed that these items should be re-planned to align with S200 (Depending allocation of Resource). It was noted that System Baseline should not be expected to be delivered at S120 as this requires full confirmation of the TSC attributes and this can not be achieved at this early stage of a project. This CR has been created specifically to cover following SE/PIL activities: WPr#55 - TSC Baseline and confirmation [Defered from S120]. Refer to original S120 ALM_Task 5406385. WPr#31 - System Baseline [Deferred from S120 as can not be completed until TSC has been reviewed and attributes set]. Refer to original S110 ALM_Task 5405979 . In addition to above PM to raise Action related to: With Quality consent; update the PV03 WPP to record re-planning of these work products. In addition raise Clarity Risk against the Resource constraints for the PIL/SE role. Identify on the associated Tasks the target dates for the re-planned Work Products., Conclusion: *2021-10-05 SINGHR9 *Related Tasks have been completed and Work Products Delivered. S200 to be run and checklist is managed separate to this CR. *2021-07-07 SINGHR9 Re-plan of key Work Products documented in related ALM_Action 5481501. Proceed to create tasks for S200 for: WPr#55 - TSC Baseline and confirmation WPr#31 - System Baseline, LogType: Other
LogType: Other, Company: ZF, Summary: [QA][WPA][PV03][S110-S120] System Baseline Work product to be released_ReAX
Provide the details for the given input
ID: 5461909, Summary: [QA][WPA][S120][PV03] TSC needs an update with the changes to PV03 for ReAx project, State: ALM_Closed, Project: /Steering/Projects/ZF/ReAx/PR47704_Core_ZF_ReAx_EPP, Company: ZF, Team: 2294505, Classification: Quality, Comments: [singh rajinder ext ext (singhr9), sep 29, 2021 4:05:42 pm cest]task for s150/s200 c40 checklist has been moved to pv03 master cr4767460, Description: Due to Resource constraints TSC and System Baseline updates could not be supported at the respective S Gates originally planned. Agreed that these items should be re-planned to align with S200 (Depending allocation of Resource). It was noted that System Baseline should not be expected to be delivered at S120 as this requires full confirmation of the TSC attributes and this can not be achieved at this early stage of a project. This CR has been created specifically to cover following SE/PIL activities: WPr#55 - TSC Baseline and confirmation [Defered from S120]. Refer to original S120 ALM_Task 5406385. WPr#31 - System Baseline [Deferred from S120 as can not be completed until TSC has been reviewed and attributes set]. Refer to original S110 ALM_Task 5405979 . In addition to above PM to raise Action related to: With Quality consent; update the PV03 WPP to record re-planning of these work products. In addition raise Clarity Risk against the Resource constraints for the PIL/SE role. Identify on the associated Tasks the target dates for the re-planned Work Products., Conclusion: *2021-10-05 SINGHR9 *Related Tasks have been completed and Work Products Delivered. S200 to be run and checklist is managed separate to this CR. *2021-07-07 SINGHR9 Re-plan of key Work Products documented in related ALM_Action 5481501. Proceed to create tasks for S200 for: WPr#55 - TSC Baseline and confirmation WPr#31 - System Baseline, LogType: Other
ID: 5461909
Provide the details for the given ID
ID: 5461909, Summary: [QA][WPA][S120][PV03] TSC needs an update with the changes to PV03 for ReAx project, State: ALM_Closed, Project: /Steering/Projects/ZF/ReAx/PR47704_Core_ZF_ReAx_EPP, Company: ZF, Team: 2294505, Classification: Quality, Comments: [singh rajinder ext ext (singhr9), sep 29, 2021 4:05:42 pm cest]task for s150/s200 c40 checklist has been moved to pv03 master cr4767460, Description: Due to Resource constraints TSC and System Baseline updates could not be supported at the respective S Gates originally planned. Agreed that these items should be re-planned to align with S200 (Depending allocation of Resource). It was noted that System Baseline should not be expected to be delivered at S120 as this requires full confirmation of the TSC attributes and this can not be achieved at this early stage of a project. This CR has been created specifically to cover following SE/PIL activities: WPr#55 - TSC Baseline and confirmation [Defered from S120]. Refer to original S120 ALM_Task 5406385. WPr#31 - System Baseline [Deferred from S120 as can not be completed until TSC has been reviewed and attributes set]. Refer to original S110 ALM_Task 5405979 . In addition to above PM to raise Action related to: With Quality consent; update the PV03 WPP to record re-planning of these work products. In addition raise Clarity Risk against the Resource constraints for the PIL/SE role. Identify on the associated Tasks the target dates for the re-planned Work Products., Conclusion: *2021-10-05 SINGHR9 *Related Tasks have been completed and Work Products Delivered. S200 to be run and checklist is managed separate to this CR. *2021-07-07 SINGHR9 Re-plan of key Work Products documented in related ALM_Action 5481501. Proceed to create tasks for S200 for: WPr#55 - TSC Baseline and confirmation WPr#31 - System Baseline, LogType: Other
Summary: [QA][WPA][S120][PV03] TSC needs an update with the changes to PV03 for ReAx project
Provide the details for the given Summary
ID: 5461909, Summary: [QA][WPA][S120][PV03] TSC needs an update with the changes to PV03 for ReAx project, State: ALM_Closed, Project: /Steering/Projects/ZF/ReAx/PR47704_Core_ZF_ReAx_EPP, Company: ZF, Team: 2294505, Classification: Quality, Comments: [singh rajinder ext ext (singhr9), sep 29, 2021 4:05:42 pm cest]task for s150/s200 c40 checklist has been moved to pv03 master cr4767460, Description: Due to Resource constraints TSC and System Baseline updates could not be supported at the respective S Gates originally planned. Agreed that these items should be re-planned to align with S200 (Depending allocation of Resource). It was noted that System Baseline should not be expected to be delivered at S120 as this requires full confirmation of the TSC attributes and this can not be achieved at this early stage of a project. This CR has been created specifically to cover following SE/PIL activities: WPr#55 - TSC Baseline and confirmation [Defered from S120]. Refer to original S120 ALM_Task 5406385. WPr#31 - System Baseline [Deferred from S120 as can not be completed until TSC has been reviewed and attributes set]. Refer to original S110 ALM_Task 5405979 . In addition to above PM to raise Action related to: With Quality consent; update the PV03 WPP to record re-planning of these work products. In addition raise Clarity Risk against the Resource constraints for the PIL/SE role. Identify on the associated Tasks the target dates for the re-planned Work Products., Conclusion: *2021-10-05 SINGHR9 *Related Tasks have been completed and Work Products Delivered. S200 to be run and checklist is managed separate to this CR. *2021-07-07 SINGHR9 Re-plan of key Work Products documented in related ALM_Action 5481501. Proceed to create tasks for S200 for: WPr#55 - TSC Baseline and confirmation WPr#31 - System Baseline, LogType: Other
LogType: Other, Company: ZF, Summary: [QA][WPA][S120][PV03] TSC needs an update with the changes to PV03 for ReAx project
Provide the details for the given input