did
int64 0
671
| query
stringlengths 6
865
| name
stringlengths 1
75
| datatype
stringclasses 6
values | unit
stringclasses 5
values | IRDI
stringlengths 20
21
| metalabel
int64 1
37
|
---|---|---|---|---|---|---|
300 | actual value of the discrete input unit | discrete input value | null | null | 0173-1#02-ABC146#001 | 13 |
301 | actual value of the discrete output unit | discrete output value | null | null | 0173-1#02-ABC142#001 | 13 |
302 | user-defined value for use with fault action property | fault value | STRING | null | 0173-1#02-ABC130#001 | 1 |
303 | total number of transitions of the value from th off to the on state | on off cycle | INTEGER | null | 0173-1#02-ABC141#001 | 31 |
304 | desired operation mode of the pump | set operation mode | STRING | null | 0173-1#02-ABC140#001 | 1 |
305 | desired control mode of the pump | set control mode | STRING | null | 0173-1#02-ABC139#001 | 1 |
306 | actual status of the element | property-status | null | null | 0173-1#02-ABC132#001 | 13 |
307 | operation status of a machine | on/off | null | null | 0173-1#02-ABC131#001 | 13 |
308 | input variable to a comparing element in a controlling system, which sets the desired value of the controlled variable and is deducted from the command variable | reference variable | REAL_MEASURE | null | 0173-1#02-ABC128#001 | 19 |
309 | output variable of the controlling system, which is also an input variable of the controlled system | manipulated variable | STRING | null | 0173-1#02-ABC125#001 | 1 |
310 | variable quantity, which represents the controlled variable and is returned to the comparing element | feedback variable | REAL_MEASURE | null | 0173-1#02-ABC122#001 | 19 |
311 | duration of the time interval by which the output variable is shifted relative to the input variable | dead time | REAL_MEASURE | null | 0173-1#02-AAM698#005 | 19 |
312 | proportional element, the quotient of the variation of the output variable to the corresponding variation of the input variable | proportional action coefficient | STRING | null | 0173-1#02-ABC127#001 | 1 |
313 | characterization of the way and the extent to which the human operator intervenes in the control equipment | operating mode | STRING | null | 0173-1#02-ABC126#001 | 1 |
314 | integral element, the quotient of the time derivative of the output variable to the fixed value of the input variable | integral action coefficient | STRING | null | 0173-1#02-ABC124#001 | 1 |
315 | variable quantity which has, or combination of variable quantities which have, to be influenced by the control | final controlled variable | REAL_MEASURE | null | 0173-1#02-ABC123#001 | 19 |
316 | for a derivative element, the quotient of the value of the output variable to the value of the time derivative of the input variable | derivative action coefficient | STRING | null | 0173-1#02-ABC121#001 | 1 |
317 | output variable of the controlling element, which is deducted from the control difference variable and is also the input variable of the actuator | controller output variable | REAL_MEASURE | null | 0173-1#02-ABC120#001 | 19 |
318 | output variable of the controlled system that will be acted upon by one or more manipulated variables | controlled variable | REAL_MEASURE | null | 0173-1#02-ABC119#001 | 19 |
319 | difference between the reference variable and the feedback variable | control difference variable | REAL_MEASURE | null | 0173-1#02-ABC118#001 | 19 |
320 | variable quantity, which is not influenced by the control but is introduced into the control system from outside with the aim of making the final controlled variable follow it in a given relationship | command variable | REAL_MEASURE | null | 0173-1#02-ABC117#001 | 19 |
321 | absolute static pressure of the emerging mixture immediate downstream the pressure connection | Counterpressure | null | null | 0173-1#02-BAJ129#007 | 13 |
322 | temperature of the refrigerating agent used for cooling | Coolant temperature | REAL_MEASURE | null | 0173-1#02-AAB758#006 | 19 |
323 | measured rate of flow passing through the exit from the volute divided by the throat area | mean velocity at throat | REAL_MEASURE | null | 0173-1#02-ABC161#001 | 19 |
324 | measured power transmitted to the pump by its driver | water pump power consumption | REAL_MEASURE | null | 0173-1#02-AAJ763#003 | 19 |
325 | amount of the absolute value of the total head above the head, equivalent to the vapour pressure of the liquid at the particular temperature, with reference to the NPSH datum plane | net positive suction head | REAL_MEASURE | null | 0173-1#02-ABC164#001 | 19 |
326 | difference between the total head at the outlet side of the pump and the total head at the inlet side of the pump | lift circulating pump | REAL_MEASURE | null | 0173-1#02-AAI540#004 | 19 |
327 | measured dfifference between instantaneous pressure and static pressure | sound pressure | REAL_MEASURE | null | 0173-1#02-ABC178#001 | 19 |
328 | determined through a surface, product of the sound pressure, p, and the component of the particle velocity, un, at a point on the surface in the direction normal to the surface, integrated over that surface | sound power | REAL_MEASURE | null | 0173-1#02-ABC177#001 | 19 |
329 | determined integral of the sound power, p, over a stated time interval of duration t (starting at t1 and ending at t2) | sound energy | REAL_MEASURE | null | 0173-1#02-ABC175#001 | 19 |
330 | measured residual force acting at right angles to the line of the shaft and derived from hydraulic forces | radial load of pump rotor | REAL_MEASURE | null | 0173-1#02-ABC174#001 | 19 |
331 | measured temperature of the pump | pump temperature | REAL_MEASURE | null | 0173-1#02-ABC173#001 | 19 |
332 | measured rate of flow leaking from shaft seals | leakage rate of flow | REAL_MEASURE | null | 0173-1#02-ABC157#001 | 19 |
333 | measured clearance flow between the housing and the impeller | clearance flow | REAL_MEASURE | null | 0173-1#02-ABC151#001 | 19 |
334 | determined power loss due clearance flows | power loss due to internal leakage | REAL_MEASURE | null | 0173-1#02-ABC168#001 | 19 |
335 | measured position of the axial rotor in bearing | axial rotor position | REAL_TYPE | null | 0173-1#02-ABC149#001 | 37 |
336 | measured residual thrust acting through the shaft derived from hydraulic or mechanical forces | axial load of pump rotor | REAL_MEASURE | null | 0173-1#02-ABC148#001 | 19 |
337 | ten times the logarithm to the base 10 of the ratio of the sound power of a source, p, to a reference value, p0, expressed in decibels | sound output level | null | null | 0173-1#02-BAA081#005 | 13 |
338 | measured oil pressure of the lubrication system | lubricating oil pressure | REAL_MEASURE | null | 0173-1#02-ABC160#001 | 19 |
339 | measured oil consumption of the lubricating system | lubricating oil consumption | REAL_MEASURE | null | 0173-1#02-ABC159#001 | 19 |
340 | measured level | level | REAL_MEASURE | null | 0173-1#02-ABC158#001 | 19 |
341 | part of the active maintenance time taken to perform a preventive maintenance | active preventive maintenance time | REAL_MEASURE | null | 0173-1#02-ABA746#001 | 19 |
342 | part of maintenance time when preventive maintenance is carried out on an item, including technical, logistic and internal administrative delay | preventive maintenance time | REAL_MEASURE | null | 0173-1#02-ABA745#001 | 19 |
343 | maintainability of an item determined by the design under expected conditions of maintenance and logistic support | intrinsic maintainability | REAL_MEASURE | null | 0173-1#02-ABA734#001 | 19 |
344 | Percent probability of a fault-free operation over the period of time specified under the reliability period under specified environmental conditions | Reliability according to norm | REAL_MEASURE | null | 0173-1#02-AAY978#001 | 19 |
345 | average of the time to restauration | time to restoration | REAL_MEASURE | null | 0173-1#02-ABA728#001 | 19 |
346 | time interval throughout which an item is in a standby state | standby time | REAL_MEASURE | null | 0173-1#02-ABA726#001 | 19 |
347 | average of the time to restauration | mean time to restauration | REAL_MEASURE | null | 0173-1#02-ABA721#001 | 19 |
348 | time interval throughout which an item is in an external disabled state | external disabled time | REAL_MEASURE | null | 0173-1#02-ABA715#001 | 19 |
349 | Timescale for the mean downtime | mean downtime | REAL_MEASURE | null | 0173-1#02-AAO768#001 | 19 |
350 | delivery which is to be expected for usual operation | normal feed flow | REAL_MEASURE | null | 0173-1#02-BAJ126#007 | 19 |
351 | gauge pressure of the gaseous state of a substance which is in thermodynamic equilibrium with the liquid or solid phase of the substance at a given temperature | vapor pressure (gauge) | REAL_MEASURE | null | 0173-1#02-AAQ871#007 | 19 |
352 | head observed at outlet area of the installation, corresponding to the sum of the height, pressure head and velocity head | total head at outlet area of the installation | REAL_MEASURE | null | 0173-1#02-ABC112#001 | 19 |
353 | head observed at inlet area of the installation, corresponding to the sum of the height, pressure head and velocity head | total head at inlet area of the installation | REAL_MEASURE | null | 0173-1#02-ABC111#001 | 19 |
354 | difference between the total head at the outlet side of the installation and the total head at the inlet side of the installation | installation total head | REAL_MEASURE | null | 0173-1#02-ABC095#001 | 19 |
355 | power absorbed by friction in bearings and shaft seal at given operating conditions of the pump | pump mechanical power losses | REAL_MEASURE | null | 0173-1#02-ABC106#001 | 19 |
356 | smallest rate of flow that the pump can be expected to deliver continuously without risk of internal damage when operated at the rated speed and on the liquid for which it was supplied | Min. feed flow | REAL_MEASURE | null | 0173-1#02-BAI022#005 | 19 |
357 | greatest rate of flow the pump can be expected to deliver continuously without risk of internal damage when operated at the rated speed and on the liquid for which it was supplied | Max. feed flow | REAL_MEASURE | null | 0173-1#02-BAI023#005 | 19 |
358 | proportion of the pump power input, p, delivered as pump power output, pu, at given operating conditions | pump efficiency | REAL_MEASURE | null | 0173-1#02-ABC105#001 | 19 |
359 | proportion of the pump power input, p, available after satisfying the mechanical power losses, pj,ab, at given operating conditions | mechanical efficiency | REAL_MEASURE | null | 0173-1#02-ABC100#001 | 19 |
360 | proportion of the driver power input, pmot, delivered as pump power output, pu | overall efficiency | REAL_MEASURE | null | 0173-1#02-ABC103#001 | 19 |
361 | proportion of pump available power input, pa, which is delivered as pump power output, pu, after satisfying the losses resulting from friction due to the relative motion of internal surfaces and internal leakage | hydraulic efficiency | REAL_MEASURE | null | 0173-1#02-ABC094#001 | 19 |
362 | total pressure (including velocity pressure) at the pump inlet connection less the liquid vapour pressure at the present temperature of the liquid | net positive inlet pressure available | REAL_MEASURE | null | 0173-1#02-ABC084#001 | 19 |
363 | greatest difference between the total energy height at the outlet side of the pump aggregate and the total energy height of the intake side of the pump aggregate at operating point | maximum feed height | REAL_MEASURE | null | 0173-1#02-BAJ123#007 | 19 |
364 | absolute total inlet head above the head equivalent to the vapor pressure based on the NPSH at the operating point | NPSH-nominal | REAL_MEASURE | null | 0173-1#02-BAJ153#009 | 19 |
365 | smallest total energy height at the outlet side of the pump aggregate to the total energy height of the admission side of the pump aggregate at operating point | minimum feed height | REAL_MEASURE | null | 0173-1#02-BAJ124#008 | 19 |
366 | difference between the total energy height on the outlet side of the pump aggregate and the total energy height of the intake side of the pump aggregate ruling at operating point | nominal feed height | REAL_MEASURE | null | 0173-1#02-BAJ125#007 | 19 |
367 | representation of the pump head plotted against the flow rate | installation NPSH curve | null | null | 0173-1#02-ABB432#001 | 13 |
368 | pure number calculated at the point of best efficiency | type number | STRING | null | 0173-1#02-ABC068#001 | 1 |
369 | pump h(q) curve where the maximum head (peak point) and shut-off head are not coincidental, or the total head does not decline continuously as the rate of flow increases | stable pump H(Q) curve | null | null | 0173-1#02-ABC064#001 | 13 |
370 | Hoisting height for the feed flow Q = 0 | Zero-delivery height | REAL_MEASURE | null | 0173-1#02-BAI147#004 | 19 |
371 | power consumption at flow = 0 and speed guaranteed | Zero flow power requirement | REAL_MEASURE | null | 0173-1#02-BAJ154#008 | 19 |
372 | highest value of the mechanical power demand of the pump for any delivery flow under any permitted working conditions | maximum power requirement of the pump | REAL_MEASURE | null | 0173-1#02-BAJ143#008 | 19 |
373 | average speed given by the stroke length multiplied with the number of complete pumping cycles of the piston, plunger or piston attached to the diaphragm per minute (stroke per minute or pump crank speed) | piston velocity | REAL_MEASURE | null | 0173-1#02-ABC049#001 | 19 |
374 | volume remaining unswept at the end of the discharge stroke | clearance volume | REAL_MEASURE | null | 0173-1#02-ABA886#001 | 19 |
375 | product of geometrical displacement volume and speed of rotation or stroke frequency | geometric displacement volume | REAL_MEASURE | null | 0173-1#02-ABB160#001 | 19 |
376 | Volume of one unit of mass measure of a substance which is required for a single stroke | Stroke volume | REAL_MEASURE | null | 0173-1#02-BAA486#003 | 19 |
377 | exact, standardized agreements, to exchange data between appliances as well as processes, those which are conntected via network | supported protocol | STRING | null | 0173-1#02-AAM479#008 | 1 |
378 | indication whether an evaluation of the device for international comparison is present | conformity declaration present | BOOLEAN | null | 0173-1#02-AAC225#007 | 25 |
379 | device type according to functional principle and pumped fluid | device type | STRING | null | 0173-1#02-ABC057#001 | 1 |
380 | difference between instantaneous pressure and static pressure | sound pressure | REAL_MEASURE | null | 0173-1#02-ABC062#001 | 19 |
381 | through a surface, product of the sound pressure, p, and the component of the particle velocity, un, at a point on the surface in the direction normal to the surface, integrated over that surface | sound power | REAL_MEASURE | null | 0173-1#02-ABC061#001 | 19 |
382 | ten times the logarithm to the base 10 of the ratio of the sound energy, j, to a reference value, j0, expressed in decibels | sound energy level | REAL_MEASURE | null | 0173-1#02-ABC060#001 | 19 |
383 | integral of the sound power, p, over a stated time interval of duration t (starting at t1 and ending at t2) | sound energy | REAL_MEASURE | null | 0173-1#02-ABC059#001 | 19 |
384 | highest value of inlet pressure at which the pump or component is capable of functioning on the basis of the materials used | maximum allowable inlet pressure | REAL_MEASURE | null | 0173-1#02-ABC205#001 | 19 |
385 | free cross-sectional area of the entry opening in the inlet connection of the pump | inlet area of the pump | REAL_MEASURE | null | 0173-1#02-ABC204#001 | 19 |
386 | outlet pressure at which the relief valve begins to open | relief-valve set pressure | REAL_MEASURE | null | 0173-1#02-ABC202#001 | 19 |
387 | outlet pressure at which the relief valve will close after passing the total pump flow | relief-valve reseat pressure | REAL_MEASURE | null | 0173-1#02-ABC201#001 | 19 |
388 | pressure at the outlet of the relief valve when the valve is closed | relief-valve back pressure | REAL_MEASURE | null | 0173-1#02-ABC200#001 | 19 |
389 | outlet pressure at which the relief valve will pass the total pump flow | relief-valve accumulation pressure | REAL_MEASURE | null | 0173-1#02-ABC199#001 | 19 |
390 | total inlet pressure required to ensure there is sufficient margin to maintain the minimum instantaneous inlet pressure with adequate margin above the minimum liquid vapour pressure expected | net positive inlet pressure required | REAL_MEASURE | null | 0173-1#02-ABC209#001 | 19 |
391 | total pressure (including velocity pressure) at the pump inlet connection less the liquid vapour pressure at the present temperature of the liquid | net positive inlet pressure | REAL_MEASURE | null | 0173-1#02-ABC163#001 | 19 |
392 | mean velocity of the flow through the valve seat at the specified operating conditions | valve seat velocity | REAL_MEASURE | null | 0173-1#02-ABC114#001 | 19 |
393 | mean velocity of the flow through the valve spill area | valve spill velocity | REAL_MEASURE | null | 0173-1#02-ABC115#001 | 19 |
394 | ratio of the actual delivered volume at maximum pressure to the geometric displacement volume | volumetric efficiency | REAL_MEASURE | null | 0173-1#02-ABC116#001 | 19 |
395 | Language-independent, unambiguous code of a class within a class system | Class code of the electric motor | STRING | null | 0173-1#02-AAO714#001 | 1 |
396 | language-independent, unambiguous code of a class within a class system | code of class | STRING | null | 0173-1#02-AAO712#002 | 1 |
397 | language-independent, unambiguous code of a class within a class system | Class code of the transmission | STRING | null | 0173-1#02-AAO716#001 | 1 |
398 | Name and version status of the used classification system | Classification system of the electric motor | STRING | null | 0173-1#02-AAO717#001 | 1 |
399 | description comprising one or more words allocated to a class within a class system | description of class | STRING_TRANSLATABLE | null | 0173-1#02-AAD282#006 | 7 |
Subsets and Splits