question
stringclasses 5
values | choices
sequence | answer
class label 4
classes | negate_openai_prompt
dict | neg_question
stringclasses 5
values | fewshot_context
stringclasses 1
value | ori_prompt
stringclasses 5
values |
---|---|---|---|---|---|---|
In an SR latch built from NOR gates, which condition is not allowed | [
"S=0, R=0",
"S=0, R=1",
"S=1, R=0",
"S=1, R=1"
] | 3D
| {
"content": "Given a text in the form of a short question, a question with long context, a fill in the blank query, or multiple statements. Negate the given text by making minimal changes. Only negate the main question or intent, don't negate the provided context of the question and don't complete the cloze query. Reply with the full question and context. Be concise and don't provide any explanation.\n\nText: In an SR latch built from NOR gates, which condition is not allowed\n\nNegated text:",
"role": "user"
} | In an SR latch built from NOR gates, which condition is allowed? | In an SR latch built from NOR gates, which condition is not allowed
A. S=0, R=0
B. S=0, R=1
C. S=1, R=0
D. S=1, R=1
Answer: D |
|
In a 2 pole lap winding dc machine , the resistance of one conductor is 2Ω and total number of conductors is 100. Find the total resistance | [
"200Ω",
"100Ω",
"50Ω",
"10Ω"
] | 2C
| {
"content": "Given a text in the form of a short question, a question with long context, a fill in the blank query, or multiple statements. Negate the given text by making minimal changes. Only negate the main question or intent, don't negate the provided context of the question and don't complete the cloze query. Reply with the full question and context. Be concise and don't provide any explanation.\n\nText: In a 2 pole lap winding dc machine , the resistance of one conductor is 2Ω and total number of conductors is 100. Find the total resistance\n\nNegated text:",
"role": "user"
} | In a 2 pole lap winding dc machine , the resistance of one conductor is 2Ω and total number of conductors is 100. Find the total resistance. | In a 2 pole lap winding dc machine , the resistance of one conductor is 2Ω and total number of conductors is 100. Find the total resistance
A. 200Ω
B. 100Ω
C. 50Ω
D. 10Ω
Answer: C |
|
The coil of a moving coil meter has 100 turns, is 40 mm long and 30 mm wide. The control torque is 240*10-6 N-m on full scale. If magnetic flux density is 1Wb/m2 range of meter is | [
"1 mA.",
"2 mA.",
"3 mA.",
"4 mA."
] | 1B
| {
"content": "Given a text in the form of a short question, a question with long context, a fill in the blank query, or multiple statements. Negate the given text by making minimal changes. Only negate the main question or intent, don't negate the provided context of the question and don't complete the cloze query. Reply with the full question and context. Be concise and don't provide any explanation.\n\nText: The coil of a moving coil meter has 100 turns, is 40 mm long and 30 mm wide. The control torque is 240*10-6 N-m on full scale. If magnetic flux density is 1Wb/m2 range of meter is\n\nNegated text:",
"role": "user"
} | The coil of a moving coil meter has 100 turns, is 40 mm long and 30 mm wide. The control torque is 240*10-6 N-m on full scale. If magnetic flux density is NOT 1Wb/m2 range of meter is. | The coil of a moving coil meter has 100 turns, is 40 mm long and 30 mm wide. The control torque is 240*10-6 N-m on full scale. If magnetic flux density is 1Wb/m2 range of meter is
A. 1 mA.
B. 2 mA.
C. 3 mA.
D. 4 mA.
Answer: B |
|
Two long parallel conductors carry 100 A. If the conductors are separated by 20 mm, the force per meter of length of each conductor will be | [
"100 N.",
"0.1 N.",
"1 N.",
"0.01 N."
] | 1B
| {
"content": "Given a text in the form of a short question, a question with long context, a fill in the blank query, or multiple statements. Negate the given text by making minimal changes. Only negate the main question or intent, don't negate the provided context of the question and don't complete the cloze query. Reply with the full question and context. Be concise and don't provide any explanation.\n\nText: Two long parallel conductors carry 100 A. If the conductors are separated by 20 mm, the force per meter of length of each conductor will be\n\nNegated text:",
"role": "user"
} | Two long parallel conductors do not carry 100 A. If the conductors are separated by 20 mm, the force per meter of length of each conductor will not be. | Two long parallel conductors carry 100 A. If the conductors are separated by 20 mm, the force per meter of length of each conductor will be
A. 100 N.
B. 0.1 N.
C. 1 N.
D. 0.01 N.
Answer: B |
|
A point pole has a strength of 4π * 10^-4 weber. The force in newtons on a point pole of 4π * 1.5 * 10^-4 weber placed at a distance of 10 cm from it will be | [
"15 N.",
"20 N.",
"7.5 N.",
"3.75 N."
] | 0A
| {
"content": "Given a text in the form of a short question, a question with long context, a fill in the blank query, or multiple statements. Negate the given text by making minimal changes. Only negate the main question or intent, don't negate the provided context of the question and don't complete the cloze query. Reply with the full question and context. Be concise and don't provide any explanation.\n\nText: A point pole has a strength of 4π * 10^-4 weber. The force in newtons on a point pole of 4π * 1.5 * 10^-4 weber placed at a distance of 10 cm from it will be\n\nNegated text:",
"role": "user"
} | A point pole does not have a strength of 4π * 10^-4 weber. The force in newtons on a point pole of 4π * 1.5 * 10^-4 weber placed at a distance of 10 cm from it will not be. | A point pole has a strength of 4π * 10^-4 weber. The force in newtons on a point pole of 4π * 1.5 * 10^-4 weber placed at a distance of 10 cm from it will be
A. 15 N.
B. 20 N.
C. 7.5 N.
D. 3.75 N.
Answer: A |