MACHINE_NO
stringclasses 48
values | ERROR_ID
int64 1
999
| ERROR_CODE
stringclasses 245
values | ERROR_DESC
stringlengths 14
179
| ERROR_CATEGORY1
stringclasses 11
values | SOLUTION
stringlengths 40
290
|
---|---|---|---|---|---|
KM-ASSYM4-05 | 53 | M7052 | M7052-The dispensing cylinder cylinder does not sense the upper limit before the slide area moves, please press the reset button first | Organizational Abnormality | The solution to M7052 error is to press the reset button before moving the slide area. This will restart the machine and allow the dispensing cylinder to sense the upper limit before dispensing. This will prevent the error from occurring again |
KM-ASSYM4-05 | 55 | M7054 | M7054-The current dispensing amount is too small, please increase | Electronic control abnormality | The error M7054 usually occurs when the dispensing amount is less than the minimum amount required. To solve this error, you need to increase the dispensing amount by adjusting the settings on your printer or using a different ink cartr |
KM-ASSYM4-05 | 2 | M7001 | M7001-Start detecting that there is material in the work area, please select the work area status | Abnormal personnel operation | The solution for the error "M7001-Start detecting that there is material in the work area, please select the work area status?" is to ensure that the appropriate work area is selected before starting the processing by either re-routing |
KM-ASSYM4-05 | 65 | M7064 | M7064-X-axis servo NO readly(X15)&ERROR, please check whether the X-axis servo driver is abnormal | Electronic control abnormality | The solution for the error M7064-X-axis servo NO ready(X15)&ERROR could involve several steps. First, unplug and plug in the X-axis servo driver to check if the issue is with |
KM-ASSYM4-05 | 67 | M7066 | M7066-X axis left limit is abnormal, far away from the origin end (X10), please check whether the slide table touches the limit | Electronic control abnormality | The solution for M7066-X axis left limit error is to verify whether the slide table is touching the limit. If it is touching the limit, adjust the limit switches to stop the slide table from touching. If it is not |
KM-ASSYM4-05 | 68 | M7067 | M7067-X axis return to origin time has timed out, please check whether the slide table is abnormal or stuck | Electronic control abnormality | The error M7067 typically occurs when the X-axis slide table times out during its return to origin movement. This could be due to a malfunctioning actuator, a stuck slide table, or a problem with the home position |
KM-ASSYM4-05 | 70 | M7069 | M7069-Y axis front limit is abnormal, close to the origin end (X11), please check whether the slide table touches the limit | Electronic control abnormality | The solution for M7069-Y axis front limit is abnormal, close to the origin end (X11) is to check whether the slide table touches the limit. The problem could be caused by the slide table moving too far |
KM-ASSYM4-05 | 71 | M7070 | M7070-Y axis rear limit is abnormal, far away from the origin end (X12), please check whether the slide table touches the limit | Electronic control abnormality | There are a few possible solutions to address the error M7070-Y axis rear limit is abnormal, far away from the origin end (X12) including:
1. Adjusting the slide table position to ensure |
KM-ASSYM4-05 | 72 | M7071 | M7071-Y axis return to origin time has timed out, please check whether the slide table is abnormal or stuck | Electronic control abnormality | The M7071-Y axis return to origin time has timed out error indicates that the Y-axis slide table is not responding to commands. This can be due to a stuck or abnormal condition. To troubleshoot this issue |
KM-ASSYM4-05 | 74 | M7073 | M7073-The limit on the Z axis is abnormal, close to the origin end (X13), please check whether the slide table touches the limit | Electronic control abnormality | The solution to M7073 error that states the limit on the Z axis is abnormal, close to the origin end (X13) is to check whether the slide table touches the limit. This can be accomplished by physically inspecting |
KM-ASSYM4-05 | 75 | M7074 | M7074-Z axis lower limit abnormality, far away from the origin end (X14), please check whether the slide table touches the limit | Electronic control abnormality | The solution for the error M7074 due to the lower limit abnormality of the Z-axis, far away from the origin end (X14), is to ensure that the slide table does not touch the limit. This can |
KM-ASSYM4-05 | 81 | M7080 | M7080-Camera acquisition failed | Visual abnormality | The M7080-Camera acquisition failed error occurs when the camera is unable to acquire a clear image due to poor lighting conditions, distortion in the lens, or incorrect settings. To resolve this issue, first reset the camera and then check |
KM-ASSYM4-05 | 82 | M7081 | M7081-Timeout waiting for MARK point in place signal | Electronic control abnormality | This issue is often resolved by adjusting the default timeout value for the place signal waiting period in the configuration settings. You can either increase the timeout value or try implementing the "force Mark" button in the Mark dialog. If the issue persists, |
KM-ASSYM4-05 | 83 | M7082 | M7082-MARK point recognition failed | Visual abnormality | The solution for the M7082-MARK point recognition failed error is to reset the device's memory and perform the point recognition process again. If the issue persists, it may be necessary to consult the device's manual or contact |
KM-ASSYM4-05 | 84 | M7083 | M7083-CCD timed out waiting for PLC completion signal (please check D720=1) | Electronic control abnormality | The solution for the M7083-CCD timed out waiting for PLC completion signal error is to check that the D720=1 parameter is set correctly in the communication configuration of the PLC. If the parameter is |
KM-ASSYM4-05 | 85 | M7084 | M7084-Scan code NG | Electronic control abnormality | The M7084-Scan code NG error often indicates a connectivity issue between the scanner and the computer or printer. A possible solution is to check the connections, restart the devices, and update device drivers. If the issue pers |
KM-ASSYM4-05 | 87 | M7086 | M7086-Scan code OK and receive TE Read signal timeout | Kazam exception | This error typically occurs when there is no data available on the USB port. It could be due to a problem with the computer's USB interface or a malfunctioning printer. To resolve the issue, you may need to try restarting your computer |
KM-ASSYM4-05 | 88 | M7087 | M7087-TE LINK out of range | Kazam exception | The error M7087-TE LINK out of range typically occurs when the TTL setting of a router or access point is too low. To resolve this issue, you can increase the TTL setting on the router or access point, |
KM-ASSYM4-05 | 90 | M7089 | M7089-The dispensing area detected by the upper camera is out of range | Visual abnormality | The solution for the M7089 error is to adjust the location and orientation of the upper camera to ensure it is within range of the dispensing area. If the camera cannot be moved, the error can also be resolved by adjusting the |
KM-ASSYM4-05 | 93 | M7092 | M7092-PLC timed out while waiting for the area identification completion signal from the host computer | Visual abnormality | The solution for the M7092-PLC timed out error involving area identification completion signal from the host computer could be to reduce the timeout value in the PLC configuration, check for network connectivity issues or congestion, or |
KM-ASSYM4-05 | 94 | M7093 | M7093-PLC timed out waiting for the host computer to send the scan code result | Machine communication abnormality | The solution for the error described as M7093-PLC timed out waiting for the host computer to send the scan code result is to ensure that the host computer is properly connected and responsive, and that the PLC settings are |
KM-ASSYM4-05 | 95 | M7094 | M7094-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing | Visual abnormality | M7094-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing can be resolved by checking if the host computer is properly connected and also ensuring that there are no delays or issues with the |
KM-ASSYM4-05 | 97 | M7096 | M7096-Weighing machine communication abnormality | Electronic control abnormality | The M7096 error on a weighing machine indicates communication abnormality. The solution may involve resetting the machine, checking for any software updates, or contacting the manufacturer for further assistance. This issue typically occurs when the machine cannot |
KM-ASSYM4-05 | 98 | M7097 | M7097-The cylinder position of the glue barrel is abnormal | Organizational Abnormality | M7097 errors occur when the glue barrel's cylinder position is abnormal. To resolve this issue, you can try calibrating the glue barrel, checking for blockage in the cylinder, or performing a manual |
KM-ASSYM4-05 | 101 | M7100 | M7100-Please clean the scale pan before starting the machine, and click the Cleared button before starting the machine. | Abnormal personnel operation | The solution for this error is to clean the scale pan and click the "Cleared" button before starting the machine. If the pan cannot be cleaned, the machine must be powered off and unplugged for at least 30 minutes before |
KM-ASSYM4-05 | 102 | M7101 | M7101-Please clean the scale pan and press the "Scale Pan Easy Clean Button" | Abnormal personnel operation | The solution for the error M7101 is to clean the scale pan using a cleaning tool provided by the scale manufacturer, and then to press the "Scale Pan Easy Clean Button" to reset the scale. If the problem persists, the |
KM-ASSYM4-05 | 103 | M7102 | M7102-Weighing machine reset failed | Electronic control abnormality | M7102-Weighing machine reset failed error typically occurs when the machine cannot initialize due to an incorrect password or issue with its software. To resolve this, consult the owner manual for instructions on resetting the machine and updating its firm |
KM-ASSYM4-05 | 113 | M7112 | M7112-Visual software model number is inconsistent with PLC model number | Visual abnormality | The solution to the M7112 error is to check that the visual software model number matches the PLC model number. If both numbers are correct, then the error may be caused by a mismatch between the cable connections, power supply, |
KM-ASSYM4-05 | 114 | M7113 | M7113-Current discharging point index is out of range | Visual abnormality | The solution to the M7113 error involves updating the current discharging point settings on the device in question to within the specified range. This can typically be done through the device's user manual or settings interface. If the issue pers |
KM-ASSYM4-05 | 115 | M7114 | M7114-Timeout waiting for dispensing result | Visual abnormality | The M7114-Timeout waiting for dispensing result error typically occurs when the system is unable to complete a dispensing operation within a specified time limit. The solution may involve troubleshooting the hardware or software, adjusting the time |
KM-ASSYM4-05 | 117 | M7116 | M7116-Timeout waiting for next action | Machine communication abnormality | The M7116-Timeout waiting for next action error typically occurs when a software process is awaiting user input or a system event but is not receiving it within a specified timeout period. The solution may involve increasing the timeout limit, optimizing |
KM-ASSYM4-05 | 118 | M7117 | M7117-The number of required assemblies is more than the number of positioned cameras | Other exceptions | The M7117 error occurs when the number of required assemblies exceeds the number of positioned cameras in a camera-based manufacturing process. To resolve this issue, you can either increase the number of positioned cameras or optimize the assembly |
KM-ASSYM4-05 | 120 | M7119 | M7119-CMC responded with incorrect material number confirmation information | Abnormal personnel operation | The solution for M7119-CMC responding with incorrect material number confirmation information is to review and double-check the material number being entered, ensure it follows the correct format, and try resetting the device or running material verification checks. |
KM-ASSYM5-06 | 119 | M7118 | M7118-CMC reply material number confirmation message timeout (10S) | Machine communication abnormality | The solution for the error M7118-CMC reply material number confirmation message timeout is to increase the timeout period to 10 seconds or set it to an appropriate value based on the system's requirements. Alternatively, checking the |
KM-ASSYM5-06 | 121 | M7120 | M7120-The function of confirming the material number of the host computer CMC has been blocked | Other exceptions | To resolve M7120 error, ensure that the host computer CMC is functioning properly and has the necessary permissions to access the material number confirmation function. You may also need to update the system or application software to the latest version. If the |
KM-ASSYM5-06 | 98 | M7097 | M7097-The cylinder position of the glue barrel is abnormal | Organizational Abnormality | M7097 errors occur when the glue barrel's cylinder position is abnormal. To resolve this issue, you can try calibrating the glue barrel, checking for blockage in the cylinder, or performing a manual |
KM-ASSYM5-06 | 100 | M7099 | M7099-The current position of the PCB board is lower than the safe distance, please check whether the PCB board is placed properly | Other exceptions | The solution to M7099 error code is to check the placement of the PCB board in a safe distance, either by physically adjusting the board or fixing the position of the jig or fixture using the appropriate tools. It is crucial |
KM-ASSYM5-06 | 115 | M7114 | M7114-Timeout waiting for dispensing result | Visual abnormality | The M7114-Timeout waiting for dispensing result error typically occurs when the system is unable to complete a dispensing operation within a specified time limit. The solution may involve troubleshooting the hardware or software, adjusting the time |
KM-ASSYM5-06 | 120 | M7119 | M7119-CMC responded with incorrect material number confirmation information | Abnormal personnel operation | The solution for M7119-CMC responding with incorrect material number confirmation information is to review and double-check the material number being entered, ensure it follows the correct format, and try resetting the device or running material verification checks. |
KM-ASSYM5-07 | 1 | M70 | M70-The left labeling machine is out of material | Abnormal personnel operation | This error often occurs when the labeling machine runs out of labels or label stock. To solve it, ensure that the label machine has enough labels or label stock, and that the labels are properly loaded into the machine. Check the machine's settings |
KM-ASSYM5-07 | 5 | M74 | There is no feedback in the communication between M74-PLC and CCD, please restart the CCD part | Visual abnormality | The solution to this issue could potentially be to restart the CCD part, which could communicate with the M74-PLC and provide feedback. However, it's important to take note that this is just one possible solution and other underlying issues |
KM-ASSYM5-07 | 6 | M75 | M75-Start detecting that there is material in the work area, please select the work area status | Abnormal personnel operation | The solution for the M75-Start error is to select the work area status as "Clear" before starting the machine. If the work area is not clear, the machine will not start and will display this error message. |
KM-ASSYM5-07 | 12 | M81 | M81-Equipment model setting is abnormal, please set the model | Abnormal personnel operation | To resolve the error M81-Equipment model setting is abnormal, please set the model, follow these steps:
1. Identify the equipment in question.
2. Determine the correct model number for the equipment. |
KM-ASSYM5-07 | 13 | M82 | M82-Please press the reset button before starting the automatic process | Abnormal personnel operation | The solution to the M82 error described as "Please press the reset button before starting the automatic process" is to press the reset button and then restart the device or application that is producing the error. This will often clear any corrupted files or |
KM-ASSYM5-07 | 14 | M83 | M83-The device has not returned to the origin, please execute the device to return to the origin first | Abnormal personnel operation | The solution to the M83 error is to perform a device initialization or power cycle by turning off the radio and then back on to reset the device's location and return it to its starting point. |
KM-ASSYM5-07 | 15 | M84 | The communication connection between M84-PLC1 and PLC2 is interrupted | Machine communication abnormality | The solution for the error described as "The communication connection between M84-PLC1 and PLC2 is interrupted" may involve checking the communication protocols, ensuring proper termination of the connection, checking the modems and communication cards, |
KM-ASSYM5-07 | 17 | M86 | M86-Front buffer conveyor belt feeding operation timeout | Organizational Abnormality | The solution for the error M86-Front buffer conveyor belt feeding operation timeout is to clean the belt, tighten any loose connections, and ensure proper alignment between components. If the issue persists, check for blockages and repair or replace |
KM-ASSYM5-07 | 18 | M87 | M87-Front buffer conveyor belt discharging operation timeout | Organizational Abnormality | The solution for the M87-Front buffer conveyor belt discharging operation timeout error could involve checking the connection between the conveyor belt and the motor, ensuring the belt speed is appropriate, and verifying that there are no obstructions in |
KM-ASSYM5-07 | 19 | M88 | M88-Work area inlet conveyor belt operation timeout | Organizational Abnormality | The solution for the M88-Work area inlet conveyor belt operation timeout error could involve adjusting the conveyor belt speed, updating or replacing the equipment, or contacting the manufacturer for assistance. Regular maintenance can also help prevent this error |
KM-ASSYM5-07 | 20 | M89 | M89-Work area discharging conveyor belt operation timeout | Organizational Abnormality | The solution to the M89-Work area discharging conveyor belt operation timeout error typically involves cleaning the belt and belt feeder, removing blockages, and adjusting the conveyor speed. If the error persists, you may need |
KM-ASSYM5-07 | 21 | M90 | M90-Rear buffer conveyor belt feeding operation timeout | Organizational Abnormality | Solution to M90-Rear buffer conveyor belt feeding operation timeout error is to increase the dwell time or use a higher-capacity buffer to allow the belt more time to feed the product. If the error persists, ensure that the belt |
KM-ASSYM5-07 | 22 | M91 | M91-Rear buffer conveyor belt discharging operation timeout | Organizational Abnormality | The solution for the M91-Rear buffer conveyor belt discharging operation timeout error may involve several troubleshooting steps. These steps could include checking the conveyor belt’s condition; enabling or disabling the rear buffer convey |
KM-ASSYM5-07 | 23 | M92 | M92-The operation of the left label discharging machine has timed out, please check the label discharging machine | Electronic control abnormality | The solution for the M92 error is recommended to check the label discharging machine for an issue preventing it from functioning properly, or contact technical support for further assistance. |
KM-ASSYM5-07 | 25 | M94 | M94- Abnormal rise of blocking cylinder in work area (X20) | Organizational Abnormality | The M94 error code indicates a problem with the blocking cylinder in the work area. To fix this, follow these steps: Check that all the blocking cylinders are functioning properly and that no obstacles are blocking the work area. If |
KM-ASSYM5-07 | 26 | M95 | M95- Abnormal descent of blocking cylinder in work area (X21) | Organizational Abnormality | The solution for M95- Abnormal descent of blocking cylinder in work area (X21) error involves checking the hydraulic cylinder, adjusting the screws and bushings, replacing or repairing the worn parts, |
PODLABEL | 17 | M7016 | M7016-EMO&&DOOR is open, please check the safety door or emergency stop X26 | Abnormal personnel operation | The solution to the M7016-EMO&&DOOR is open, please check the safety door or emergency stop X26 error would be to ensure that all doors and emergency stops are properly aligned, closed, and operating correctly. |
KM-ASSYM3-05 | 39 | M108 | M108-Y axis servo NO readly & ERROR (X11) | Electronic control abnormality | The solution for the error described as M108-Y axis servo NO readly & ERROR (X11) is to reset the printer's configuration or check for any servo problems or update the printer software. If the issue |
KM-ASSYM3-05 | 40 | M109 | M109-Y axis front limit abnormality (X7) | Electronic control abnormality | The M109-Y axis front limit abnormality (X7) error occurs when the Y-axis position or velocity exceeds the front limit, which can be caused by a damaged Y-axis motor or a faulty limit switch |
KM-ASSYM3-05 | 41 | M110 | M110-Y axis rear limit abnormality (X6) | Electronic control abnormality | The solution to the M110-Y axis rear limit abnormality (X6) error may involve adjusting the rear limit switch to ensure it is properly aligned with the rear of the bed. If it is still inaccurate after |
KM-ASSYM3-05 | 42 | M111 | M111-Y axis return to origin time timeout | Electronic control abnormality | The solution for M111-Y axis return to origin time timeout error is to increase the timeout value or configure the printer to use a faster communication speed. This can be done using the G901 command or by modifying the printer |
KM-ASSYM3-05 | 43 | M112 | M112-Nozzle 1 return to origin time timeout | Electronic control abnormality | The solution for error M112 could be to adjust the nozzle control parameters such as rate of speed and acceleration/deceleration or to upgrade the firmware of the printer. Additionally, you could also reduce the print speed |
KM-ASSYM3-05 | 44 | M113 | M113-Z axis is out of step when nozzle 1 is running, please perform origin return | Electronic control abnormality | The error M113-Z axis is out of step when nozzle 1 is running, indicating a problem with the Z-axis position of the printer. A possible solution is to perform an origin return, which involves resetting the |
KM-ASSYM3-05 | 45 | M114 | M114-Nozzle 1 manual positioning running time timeout | Electronic control abnormality | The M114-Nozzle 1 manual positioning running time timeout error indicates that the system took too long to respond to a manual positioning request for Nozzle 1. To resolve this issue, check the nozzle |
KM-ASSYM3-05 | 46 | M115 | M115-Nozzle 1 automatic positioning running time timeout | Electronic control abnormality | The solution for M115-Nozzle 1 automatic positioning running time timeout error is to check the printer's settings and configuration to ensure that the printer is set up to wait long enough for the automatic positioning process to complete |
KM-ASSYM3-05 | 47 | M116 | M116-Nozzle 1 vacuum abnormality (PLC2-X4) | Electronic control abnormality | The solution for the error M116-Nozzle 1 vacuum abnormality (PLC2-X4) typically involves checking for blockages or leaks in the nozzle and vacuum system, ensuring proper air supply, |
KM-ASSYM3-05 | 48 | M117 | M117-Nozzle 1 failed to pick up materials several times in a row | Electronic control abnormality | The solution for the error described as M117-Nozzle 1 failed to pick up materials several times in a row is to check the nozzle for clogs or jams, clean the nozzle, verify that the |
KM-ASSYM3-05 | 49 | M118 | M118-Nozzle 2 return to origin time timeout | Electronic control abnormality | The M118 error occurs when the nozzle does not return to its original position within a specified time limit. To resolve this issue, you may need to adjust the nozzle's positioning parameters or limit the print speed. |
KM-ASSYM3-05 | 50 | M119 | M119-Z axis is out of step when nozzle 2 is running, please perform origin return | Electronic control abnormality | This error is related to the Z-axis being out of step during printing while Nozzle 2 is running. To resolve this, an origin return must be performed to reset the printer's coordinates and ensure smooth operation. |
KM-ASSYM3-05 | 51 | M120 | M120-Nozzle 2 manual positioning running time timeout | Electronic control abnormality | The M120 error may occur when the manual positioning of Nozzle 2 exceeds the prescribed time limit. This could be due to several reasons like slow printing speeds, insufficient ink or paper supply, or a software gl |
KM-ASSYM3-05 | 52 | M121 | M121-Nozzle 2 automatic positioning running time timeout | Electronic control abnormality | The error M121-Nozzle 2 automatic positioning is likely occurring because the nozzle is not sensing the correct position or because there is a connectivity issue between the nozzle and the printer's computer. |
KM-ASSYM3-05 | 53 | M122 | M122-Nozzle 2 vacuum abnormality (PLC2-X5) | Electronic control abnormality | The M122 error code indicates a vacuum abnormality in Nozzle 2 of a PLC2-X5 machinery. The solution depends on the root cause, but it could involve cleaning the nozzle or replacing a damaged |
KM-ASSYM3-05 | 54 | M123 | M123-Nozzle 2 failed to pick up materials several times in a row | Electronic control abnormality | The solution to the error M123-Nozzle 2 failed to pick up materials several times in a row is to check for any blockages or clogs in the nozzle, and to verify that the material you are trying |
KM-ASSYM3-05 | 55 | M124 | M124-Nozzle 1 or Nozzle 2 initialization time timeout | Electronic control abnormality | The solution for M124-Nozzle initialization time timeout error could be resetting the printer, updating the firmware or printer settings, ensuring adequate printer maintenance, or utilizing the printer's diagnostic functionality to determine and resolve the issue. |
KM-ASSYM3-05 | 56 | M125 | M125-Suction nozzles 1&2 have not reached the safe height when the slide is running (PLC2-X0, X1) | Electronic control abnormality | The solution to the M125-Suction nozzles 1&2 have not reached the safe height error when the slide is running (PLC2-X0, X1) may involve adjusting the nozzle height |
KM-ASSYM3-05 | 57 | M126 | M126-Nozzle 1&2 Z axis origin sensor abnormality (PLC2-X0, X1) | Sensor abnormality | The solution for the M126 error involving nozzle 1&2 Z axis origin sensor abnormality in a PLC2-X0, X1 system might require calibration, maintenance, or replacement of the Z axis origin |
KM-ASSYM3-05 | 58 | M127 | M127-Nozzle 1 does not sense the Z1 axis origin sensor (PLC2-X0) | Sensor abnormality | The solution to the M127 error "Nozzle 1 does not sense the Z1 axis origin sensor (PLC2-X0)" would involve troubleshooting the Z1 axis sensor on PLC2-X0 |
KM-ASSYM3-05 | 59 | M128 | M128-Nozzle 2 does not sense the Z2 axis origin sensor (PLC2-X2) | Sensor abnormality | The solution to the M128 error "Nozzle 2 does not sense the Z2 axis origin sensor (PLC2-X2)" usually involves checking and resetting the Z2-axis origin sensor or troubleshooting |
KM-ASSYM3-05 | 60 | M129 | M129-Product Marker 1 point photo failed | Visual abnormality | The solution for M129-Product Marker 1 point photo failed error is to check if the product marker has been moved or deleted from its original location. If the marker is missing, you can manually add it back by following the steps |
KM-ASSYM3-05 | 61 | M130 | M130-Product Marker 2 point photo failed | Visual abnormality | Unfortunately, there is no one solution for the M130-Product Marker 2 point photo failed error as it can be caused by various issues such as incorrect photo alignment, lighting conditions, and software compatibility. To resolve it, try adjust |
KM-ASSYM3-05 | 62 | M131 | M131-Nozzle 1 failed to take pictures with the camera 3 times in a row | Visual abnormality | The solution for M131-Nozzle 1 failed to take pictures with the camera 3 times in a row may require a faulty camera or nozzle, check connections, software updates, or replace the malfunctioning component |
KM-ASSYM3-05 | 63 | M132 | M132-Nozzle 2 failed to take pictures with the camera 3 times in a row | Visual abnormality | There could be several reasons for this error, including issues with camera hardware or software, connectivity problems, incorrect settings, or problems with the printer's firmware or drivers. The best solution would be to troubleshoot the camera and printer settings |
KM-ASSYM3-05 | 64 | M133 | M133-Failed to take photos of materials on the left tray three times in a row | Visual abnormality | The solution to the error M133-Failed to take photos of materials on the left tray three times in a row could involve troubleshooting steps such as checking camera settings, ensuring proper lighting, cleaning the camera lens, or restarting |
KM-ASSYM3-05 | 65 | M134 | M134-Failed to take photos of materials on the right tray three times in a row | Visual abnormality | The M134 error occurs when the machine is unable to take photos of materials on the right tray three times in a row. To solve this error, you can check if the tray is in the correct position and if there are any obstructions |
KM-ASSYM3-05 | 66 | M135 | M135-Up camera & lower camera failed to capture images | Visual abnormality | The solution for M135-Up camera & Lower camera failed to capture images error can be found by checking the settings of the cameras, ensuring that the memory card is properly formatted and inserted, checking the battery life, and restarting the |
KM-ASSYM3-05 | 67 | M136 | The connection between M136-CCD and PLC failed | Visual abnormality | The solution for the error "The connection between M136-CCD and PLC failed" would be to check the connections between the two devices, ensure that they are properly configured and functioning properly, and if necessary, troubleshoot the |
KM-ASSYM3-05 | 68 | M137 | M137-CCD reads PLC product detection request signal timeout (D207=1-12) | Electronic control abnormality | The error described as M137-CCD reads PLC product detection request signal timeout (D207=1-12) occurs when the PLC does not detect the presence of a product after a specified time due to a |
KM-ASSYM3-05 | 69 | M138 | M138-CCD reads the PLC Marker point photo request signal timeout (D206=1) | Visual abnormality | M138-CCD reads the PLC Marker point photo request signal timeout (D206=1) indicates that the marker point photo request did not receive a response from the PLC. This could be due to communication issues |
KM-ASSYM3-05 | 70 | M139 | M139-CCD times out when reading the PLC material retrieval request signal (read D209=1 or D219=1) | Electronic control abnormality | The solution for the "M139-CCD times out when reading the PLC material retrieval request signal (read D209=1 or D219=1)" error is to check the signal wiring and ensure |
KM-ASSYM3-05 | 71 | M140 | M140-CCD reads PLC single-round completion signal timeout (read D720=1) | Electronic control abnormality | The solution for the error M140-CCD reads PLC single-round completion signal timeout (read D720=1) is to first verify that the PLC timer parameter is set correctly to match the time required for the |
KM-ASSYM3-05 | 72 | M141 | M141-CCD reads the PLC right material picking completion signal timeout (read D228=1) | Electronic control abnormality | The M141-CCD error occurs when the PLC fails to receive a material picking completion signal from the CCD sensor for a set timeout period. To resolve this issue, you can check the CCD sensor and cable connections, adjust |
KM-ASSYM3-05 | 73 | M142 | M142-CCD reads the CCD photo request signal under the PLC and times out (read D230=1) | Electronic control abnormality | It appears that M142-CCD and D230 are related to a photo request signal under a PLC. The error message suggests that the PLC is not able to read the signal properly and times out. Without more specific |
KM-ASSYM3-05 | 74 | M143 | M143-CCD times out when reading the PLC material picking and photographing request signal (read D202=1 or D204=1) | Visual abnormality | The solution for the M143-CCD times out error when reading the PLC material picking and photographing request signal is to increase the timeout value for the PLC interface in the device driver settings. You can try to increase the timeout |
KM-ASSYM3-05 | 75 | M144 | Assembly point is out of range | Visual abnormality | The Assembly point is out of range error occurs when the program tries to use an invalid address in an instruction. The solution is to ensure that the address being used is within the allowed range, typically 0x00000000 |
KM-ASSYM3-05 | 76 | M145 | The picking point is out of range | Visual abnormality | The error "The picking point is out of range" occurs when the coordinates of the picking point are invalid. To solve this error, make sure that the picking point's coordinates fall within the valid range and try again. |
KM-ASSYM3-05 | 77 | M146 | M146-PLC timed out waiting for the CCD to reply with the result of taking the material and taking pictures (read D202=100 or D204=100) | Visual abnormality | The solution for the M146-PLC timed out waiting for the CCD to reply with the result of taking the material and taking pictures could be to check the communication settings between the PLC and CCD and ensure that they are |
KM-ASSYM3-05 | 78 | M147 | M147-PLC timed out waiting for CCD to reply to the Mark point photo result (D206=100) | Visual abnormality | The solution for M147-PLC timeout error is to increase the timeout duration for the CCD in the PLC system. The timeout duration can be set in the PLC system's configuration, usually in the communication settings. Incre |
KM-ASSYM3-05 | 79 | M148 | M148-PLC timed out while waiting for CCD to reply with product detection and photographing results (D207=100) | Visual abnormality | M148-PLC timed out while waiting for CCD to reply with product detection and photographing results (D207=100) is an error message indicating that the control system (PLC) is unable to |
KM-ASSYM3-05 | 81 | M150 | M150-PLC timed out while waiting for CCD to send the retrieval command (D208=1&2&3&4) | Visual abnormality | The solution to M150-PLC timed out while waiting for CCD to send the retrieval command could be to increase the timeout value in the PLC programming or to add a delay between the CCD command and the PLC |
KM-ASSYM3-05 | 82 | M151 | M151-PLC timed out waiting for CCD to send the pickup coordinates of nozzle 1&2 (D210&D220) | Visual abnormality | The solution for the M151-PLC error is to increase the timeout value in the PLC program for the CCD camera to send the pickup coordinates of nozzles 1 and 2. |
KM-ASSYM3-05 | 80 | M149 | M149-PLC timed out while waiting for CCD reply to the camera photo taking result (D230=100 or 101) | Visual abnormality | The error M149-PLC timed out while waiting for CCD reply to the camera photo taking result indicates that the PLC is waiting for a response from the CCD camera but is not receiving a reply. This error can be |