KM-ASSYM3-05
83
M152
M152-PLC timed out waiting for CCD to send nozzle 1&2 discharging coordinates (D700&D710)
Visual abnormality
The solution for error M152-PLC timed out waiting for CCD to send nozzle 1&2 discharging coordinates (D700&D710) could involve adjusting the timing settings between
KM-ASSYM4-05
34
M7033
M7033-The discharging operation of the front Buffer conveyor belt has timed out. Please check whether there is a jam between the front Buffer and the work area in the machine.
Organizational Abnormality
The solution for the M7033 error described as "Discharging operation of the front Buffer conveyor belt has timed out" is to check for any jam or obstruction between the front Buffer and the work area in the machine
KM-ASSYM4-05
86
M7085
M7085-TE reply card station Fail
Kazam exception
The solution for the error described as M7085-TE may vary depending on the specific issue and configuration of the system. It could involve resetting or updating the reply card station, checking for communication issues, or consulting the system documentation for
KM-ASSYM4-05
89
M7088
M7088-TE LINK timeout
Kazam exception
The solution for the error described as M7088-TE LINK timeout involves checking the network connection, verifying the routing settings, and restarting the network or server.
KM-ASSYM4-05
92
M7091
M7091-PLC timed out waiting for the host computer to transmit the dispensing point position
Visual abnormality
The solution for M7091-PLC time-out error is to ensure that the host computer is transmitting dispensing point position information to the PLC. The issue could also be caused by communication between the two devices being disabled or
KM-ASSYM4-05
96
M7095
M7095-PLC timed out waiting for the host computer to transmit the weighing result
Machine communication abnormality
The solution for M7095-PLC timed out waiting for the host computer to transmit the weighing result can be resolved by checking the communication settings in the PLC and making sure they are correct, resetting the PLC and
KM-ASSYM4-05
99
M7098
M7098-The current position of the PCB board exceeds the safe distance, please check whether the PC board is placed properly
Other exceptions
The solution to M7098 error is to check whether the PCB board is placed correctly and not exceeding the safe distance. The board should be centered properly and securely fastened to prevent any damage to the components or the board itself
KM-ASSYM4-05
104
M7103
M7103 - The scan code of this site is OK, TE replies that the previous section has not passed the site or SFC failed to transmit data
Kazam exception
The solution for the error M7103, where SFC failed to transmit data before the previous section passed the site scan, is to make sure that the SFC (Scan Flexible Charge) cable is properly connected to the printer
KM-ASSYM4-05
116
M7115
M7115-The discharge point exceeds the index range
Visual abnormality
The error "M7115-The discharge point exceeds the index range" indicates a problem in the discharge of stored procedures. To resolve this issue, you can check the discharge point value and modify it within the index range
KM-ASSYM4-05
119
M7118
M7118-CMC reply material number confirmation message timeout (10S)
Machine communication abnormality
The solution for the error M7118-CMC reply material number confirmation message timeout is to increase the timeout period to 10 seconds or set it to an appropriate value based on the system's requirements. Alternatively, checking the
KM-ASSYM4-05
20
M7019
M7019-The device has not returned to the origin, please execute the device to return to the origin first
Abnormal personnel operation
The solution to the M7019 error is to first execute the device to return to its origin before attempting any further actions. This error occurs when a device is not properly synchronized with its origin, and it requires the device to be returned to
KM-ASSYM4-05
54
M7053
M7053-The current glue amount is too much, please reduce it
Electronic control abnormality
Reduce the current glue amount by using less adhesive, replacing damaged parts, or adjusting the bonding process to ensure proper adhesion. In some cases, the use of a different type of adhesive or solvent may
KM-ASSYM4-05
66
M7065
M7065-The right limit of the X-axis is abnormal, close to the origin end (X7), please check whether the slide table touches the limit
Electronic control abnormality
The solution for the M7065 error is to check if the slide table is touching the limit at the origin end (X7) and increase the left limit value if necessary to prevent the issue.
KM-ASSYM4-05
69
M7068
M7068-Y-axis servo NO readly(X16)&ERROR, please check whether the X-axis servo driver is abnormal
Electronic control abnormality
The solution for the error described as M7068-Y-axis servo NO readly(X16) &ERROR is to confirm whether the X-axis servo driver is functioning correctly. This can be done by using the
KM-ASSYM4-05
73
M7072
M7072-Z-axis servo NO readly(X17)&ERROR, please check whether the Z-axis servo driver is abnormal
Electronic control abnormality
The error M7072-Z-axis servo NO readly(X17)&ERROR typically indicates an issue with the Z-axis servo driver circuitry. It is recommended to first check for wiring errors or loose connections
KM-ASSYM4-05
76
M7075
M7075-Z axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
Electronic control abnormality
To resolve the M7075 error where the Z axis return to origin has timed out, make sure to check the slide table abnormality or sticking condition. If it is normal, the problem may be with the encoder or the
KM-ASSYM4-05
91
M7090
M7090-PLC timed out waiting for the host computer to transmit the MARK point identification signal
Visual abnormality
The M7090-PLC error occurs when the host computer fails to transmit the MARK point identification signal within the specified timeline. To resolve this issue, first confirm that the host computer is correctly configured and sends the signal within the
KM-ASSYM4-05
33
M7032
M7032-The feeding operation of the front Buffer conveyor belt times out, please check whether there is any jamming between the upper and lower reaches of the machine
Organizational Abnormality
The error M7032 indicates that the feeding operation of the front buffer conveyor belt has timed out, which may be due to jamming between the upper and lower reaches of the machine. The solution to this issue is to check for
KM-ASSYM4-05
38
M7037
M7037-The discharging operation of the rear buffer conveyor belt times out, please check whether there is any jamming between the upper and lower reaches of the machine
Organizational Abnormality
M7037 error occurs when the discharging operation of the rear buffer conveyor belt times out and there is jamming between the upper and lower reaches of the machine. The solution is to clear any jamming in the machine, ensuring
KM-ASSYM4-05
50
M7049
M7049-The cylinder of the left glue cylinder in the slide area is abnormally descending (X54), please check whether the cylinder is stuck when descending
Organizational Abnormality
If you encounter the error M7049-The cylinder of the left glue cylinder in the slide area is abnormally descending (X54), it may indicate that the cylinder is stuck or has a problem with
KM-ASSYM4-05
100
M7099
The current position of M7099-PCB board is lower than the safe distance, please check whether the PC board is placed properly
Other exceptions
The solution to the error "The current position of M7099-PCB board is lower than the safe distance, please check whether the PC board is placed properly" would be to double-check the placement of the M709
KM-ASSYM4-05
105
M7104
M7104-The host computer did not read the READ signal sent by TE, LINK fail
Kazam exception
The M7104 error indicates that the host computer failed to read the READ signal sent by TE (Telecom Equipment) and resulted in a LINK fail. This issue may occur when the fiber optic cable is damaged, or there is
KM-ASSYM4-05
121
M7120
M7120-The function of confirming the material number of the host computer CMC has been blocked
Other exceptions
To resolve M7120 error, ensure that the host computer CMC is functioning properly and has the necessary permissions to access the material number confirmation function. You may also need to update the system or application software to the latest version. If the
KM-ASSYM4-05
17
M7016
M7016-Emergency stop&&safety door is open, please check the safety door and emergency stop switch (X30)
Abnormal personnel operation
The solution for the M7016-Emergency stop&& safety door is open error is to check the safety door and emergency stop switch (X30). Make sure that the safety door is closed and the emergency stop switch is turned
KM-ASSYM4-05
13
M7012
M7012-7 point detection failed
Visual abnormality
M7012-7 error occurs when the camera cannot detect any point on an object during image processing. This can be due to poor image quality or lighting conditions. A possible solution is to adjust the camera parameters, such as focus or bright
KM-ASSYM4-05
16
M7015
M7015-10 point detection failed
Visual abnormality
The solution for M7015-10 error, point detection failed, may refer to re-enabling point detection in the camera's settings, correcting the camera's focus and resolution, or updating the camera driver. In
KM-ASSYM4-05
19
M7018
M7018-The automatic process is not reset before starting, please press the reset button first
Abnormal personnel operation
The solution to the M7018 error is to press the reset button first before attempting to start the automatic process. Once the reset is complete, the process should restart without any issues.
KM-ASSYM5-07
27
M96
M96- Abnormal rise of jacking cylinder in work area (X22)
Organizational Abnormality
The solution for the M96 error code "Abnormal rise of jacking cylinder in work area (X22)" would typically involve performing a thorough inspection of the equipment to identify any faulty components or loose connections. Once the cause of
KM-ASSYM5-07
28
M97
M97 - Abnormal descent of jacking cylinder in work area (X23)
Organizational Abnormality
The solution for M97 Abnormal descent of jacking cylinder in work area (X23) is to inspect the jacking cylinder and its components for damage or defects, and ensure proper maintenance and safe operation of the jacking
KM-ASSYM5-07
35
M104
M104-X axis servo NO readly & ERROR (X10)
Electronic control abnormality
The solution for the M104-X axis servo NO readly and ERROR (X10) can vary depending on the specific issue, but it often involves checking the connections between the servo and the motherboard, confirming that
KM-ASSYM5-07
36
M105
M105-X axis right limit abnormality (X5)
Electronic control abnormality
To resolve a M105-X axis right limit abnormality (X5) error, you should first ensure that the printer has a manual mode enabled. Then, you can adjust the print bed's position and level until the error
KM-ASSYM5-07
37
M106
M106-X axis left limit abnormality (X4)
Electronic control abnormality
The M106 error message usually indicates abnormalities in the X-axis motion control of your printer. One possible solution is to adjust the bed leveling procedure and calibration process to prevent the left limit of the bed from touching or going
KM-ASSYM5-07
38
M107
M107-X axis return to origin time timeout
Electronic control abnormality
The error M107-X axis return to origin timeout indicates that the machine is experiencing a timing issue while returning to the origin position. This error typically occurs when there is a problem with the encoder or motor that is causing the axis to
KM-ASSYM5-07
39
M108
M108-Y axis servo NO readly & ERROR (X11)
Electronic control abnormality
The solution for the error described as M108-Y axis servo NO readly & ERROR (X11) is to reset the printer's configuration or check for any servo problems or update the printer software. If the issue
KM-ASSYM5-07
40
M109
M109-Y axis front limit abnormality (X7)
Electronic control abnormality
The M109-Y axis front limit abnormality (X7) error occurs when the Y-axis position or velocity exceeds the front limit, which can be caused by a damaged Y-axis motor or a faulty limit switch
KM-ASSYM5-07
41
M110
M110-Y axis rear limit abnormality (X6)
Electronic control abnormality
The solution to the M110-Y axis rear limit abnormality (X6) error may involve adjusting the rear limit switch to ensure it is properly aligned with the rear of the bed. If it is still inaccurate after
KM-ASSYM5-07
42
M111
M111-Y axis return to origin time timeout
Electronic control abnormality
The solution for M111-Y axis return to origin time timeout error is to increase the timeout value or configure the printer to use a faster communication speed. This can be done using the G901 command or by modifying the printer
KM-ASSYM5-07
43
M112
M112-Nozzle 1 return to origin time timeout
Electronic control abnormality
The solution for error M112 could be to adjust the nozzle control parameters such as rate of speed and acceleration/deceleration or to upgrade the firmware of the printer. Additionally, you could also reduce the print speed
KM-ASSYM5-07
44
M113
M113-Z axis is out of step when nozzle 1 is running, please perform origin return
Electronic control abnormality
The error M113-Z axis is out of step when nozzle 1 is running, indicating a problem with the Z-axis position of the printer. A possible solution is to perform an origin return, which involves resetting the
KM-ASSYM5-07
45
M114
M114-Nozzle 1 manual positioning running time timeout
Electronic control abnormality
The M114-Nozzle 1 manual positioning running time timeout error indicates that the system took too long to respond to a manual positioning request for Nozzle 1. To resolve this issue, check the nozzle
KM-ASSYM5-07
46
M115
M115-Nozzle 1 automatic positioning running time timeout
Electronic control abnormality
The solution for M115-Nozzle 1 automatic positioning running time timeout error is to check the printer's settings and configuration to ensure that the printer is set up to wait long enough for the automatic positioning process to complete
KM-ASSYM5-07
47
M116
M116-Nozzle 1 vacuum abnormality (PLC2-X4)
Electronic control abnormality
The solution for the error M116-Nozzle 1 vacuum abnormality (PLC2-X4) typically involves checking for blockages or leaks in the nozzle and vacuum system, ensuring proper air supply,
KM-ASSYM5-07
48
M117
M117-Nozzle 1 failed to pick up materials several times in a row
Electronic control abnormality
The solution for the error described as M117-Nozzle 1 failed to pick up materials several times in a row is to check the nozzle for clogs or jams, clean the nozzle, verify that the
KM-ASSYM5-07
49
M118
M118-Nozzle 2 return to origin time timeout
Electronic control abnormality
The M118 error occurs when the nozzle does not return to its original position within a specified time limit. To resolve this issue, you may need to adjust the nozzle's positioning parameters or limit the print speed.
KM-ASSYM5-07
50
M119
M119-Z axis is out of step when nozzle 2 is running, please perform origin return
Electronic control abnormality
This error is related to the Z-axis being out of step during printing while Nozzle 2 is running. To resolve this, an origin return must be performed to reset the printer's coordinates and ensure smooth operation.
KM-ASSYM5-07
51
M120
M120-Nozzle 2 manual positioning running time timeout
Electronic control abnormality
The M120 error may occur when the manual positioning of Nozzle 2 exceeds the prescribed time limit. This could be due to several reasons like slow printing speeds, insufficient ink or paper supply, or a software gl
KM-ASSYM5-07
52
M121
M121-Nozzle 2 automatic positioning running time timeout
Electronic control abnormality
The error M121-Nozzle 2 automatic positioning is likely occurring because the nozzle is not sensing the correct position or because there is a connectivity issue between the nozzle and the printer's computer.
KM-ASSYM5-07
53
M122
M122-Nozzle 2 vacuum abnormality (PLC2-X5)
Electronic control abnormality
The M122 error code indicates a vacuum abnormality in Nozzle 2 of a PLC2-X5 machinery. The solution depends on the root cause, but it could involve cleaning the nozzle or replacing a damaged
KM-ASSYM5-07
54
M123
M123-Nozzle 2 failed to pick up materials several times in a row
Electronic control abnormality
The solution to the error M123-Nozzle 2 failed to pick up materials several times in a row is to check for any blockages or clogs in the nozzle, and to verify that the material you are trying
KM-ASSYM5-07
55
M124
M124-Nozzle 1 or Nozzle 2 initialization time timeout
Electronic control abnormality
The solution for M124-Nozzle initialization time timeout error could be resetting the printer, updating the firmware or printer settings, ensuring adequate printer maintenance, or utilizing the printer's diagnostic functionality to determine and resolve the issue.
KM-ASSYM5-07
56
M125
M125-Suction nozzles 1&2 have not reached the safe height when the slide is running (PLC2-X0, X1)
Electronic control abnormality
The solution to the M125-Suction nozzles 1&2 have not reached the safe height error when the slide is running (PLC2-X0, X1) may involve adjusting the nozzle height
KM-ASSYM5-07
57
M126
M126-Nozzle 1&2-Z axis origin sensor abnormality (PLC2-X0, X2)
Sensor abnormality
The solution for M126-Nozzle 1&2-Z axis origin sensor abnormality (PLC2-X0, X2) involves calibrating the Z-axis sensors and adjusting the nozzle
KM-ASSYM5-07
58
M127
M127-Nozzle 1 does not sense the Z1 axis origin sensor (PLC2-X0)
Sensor abnormality
The solution to the M127 error "Nozzle 1 does not sense the Z1 axis origin sensor (PLC2-X0)" would involve troubleshooting the Z1 axis sensor on PLC2-X0
KM-ASSYM5-07
59
M128
M128-Nozzle 2 does not sense the Z2 axis origin sensor (PLC2-X2)
Sensor abnormality
The solution to the M128 error "Nozzle 2 does not sense the Z2 axis origin sensor (PLC2-X2)" usually involves checking and resetting the Z2-axis origin sensor or troubleshooting
KM-ASSYM5-07
60
M129
M129-Product Marker 1 point photo failed
Visual abnormality
The solution for M129-Product Marker 1 point photo failed error is to check if the product marker has been moved or deleted from its original location. If the marker is missing, you can manually add it back by following the steps
KM-ASSYM5-07
62
M131
M131-Nozzle 1 failed to take pictures with the camera 3 times in a row
Visual abnormality
The solution for M131-Nozzle 1 failed to take pictures with the camera 3 times in a row may require a faulty camera or nozzle, check connections, software updates, or replace the malfunctioning component
KM-ASSYM5-07
63
M132
M132-Nozzle 2 failed to take pictures with the camera 3 times in a row
Visual abnormality
There could be several reasons for this error, including issues with camera hardware or software, connectivity problems, incorrect settings, or problems with the printer's firmware or drivers. The best solution would be to troubleshoot the camera and printer settings
KM-ASSYM5-07
64
M133
M133-Failed to take photos of materials on the left tray three times in a row
Visual abnormality
The solution to the error M133-Failed to take photos of materials on the left tray three times in a row could involve troubleshooting steps such as checking camera settings, ensuring proper lighting, cleaning the camera lens, or restarting
KM-ASSYM5-07
66
M135
M135-Failed to take pictures with camera
Visual abnormality
The M135 error message typically indicates a problem with the camera app on an Android device. Possible solutions include updating the app, restarting the device, clearing the cache and data of the camera app, running a virus scan, and checking
KM-ASSYM5-07
67
M136
M136-Failed to take pictures with the camera
Visual abnormality
The solution for M136 error could be restarting your device, updating camera drivers, clearing cache and data of camera app, checking if the camera lens is clean, and resetting the camera settings to their defaults. If the problem persists
KM-ASSYM5-07
68
M137
M137-CCD timed out while waiting for feeder photo signal (D202=1 not received)
Visual abnormality
This error usually occurs when the camera fails to receive a feeder photo signal, which can be remedied by checking the camera settings and ensuring that the signal is enabled or adjusting the sensor sensitivity. Attempting to restart the camera or checking
KM-ASSYM5-07
69
M138
M138-CCD timed out while waiting for the left nozzle pickup request signal (D209=1 not received)
Electronic control abnormality
The M138-CCD timed out error occurs when the printer is unable to receive the left nozzle pickup request signal on D209, which may be due to a faulty nozzle, damaged wiring
KM-ASSYM5-07
70
M139
M139-CCD timed out while waiting for the left suction nozzle pickup completion signal (D218=1 not received)
Electronic control abnormality
The solution for the error described as M139-CCD timed out while waiting for the left suction nozzle pickup completion signal (D218=1 not received) is to check the wiring and connections between
KM-ASSYM5-07
71
M140
M140-CCD timed out while waiting for the right nozzle picking request signal (D219=1 not received)
Electronic control abnormality
The solution for the error M140-CCD timed out while waiting for the right nozzle picking request signal (D219=1 not received) is to ensure that the printer is properly connected to the computer, and
KM-ASSYM5-07
72
M141
M141-CCD timed out while waiting for the right nozzle pickup completion signal (D228=1 not received)
Electronic control abnormality
The solution for this error is to check that there are no obstacles blocking the nozzle pickup sensor and make sure the sensor is functioning properly. If the issue persists, consider resetting the printer.
KM-ASSYM5-07
73
M142
M142-CCD waiting for product detection request signal exceeded (D207=1-12 not received)
Electronic control abnormality
This error message indicates a problem with the camera hardware where the camera is not receiving a valid signal from the product to initiate detection. Possible causes include issues with the camera's wiring, software, or hardware components. The solution would involve
KM-ASSYM5-07
74
M143
M143-CCD timed out while waiting for the camera photo signal under the left nozzle (D230=1 not received)
Visual abnormality
The M143-CCD error indicates that the left nozzle camera photo signal has not been received. This can be caused by a number of issues, such as a loose wire connection or a problem with the camera hardware. To resolve
KM-ASSYM5-07
75
M144
M144-CCD timed out waiting for the camera photo signal under the right nozzle (D230=2 not received)
Visual abnormality
The solution for the error described as M144-CCD timed out waiting for the camera photo signal under the right nozzle (D230=2 not received) could be that there is a communication issue between the camera
KM-ASSYM5-07
76
M145
M145-CCD timed out while waiting for assembly completion signal (D720=1 not received)
Electronic control abnormality
The solution for the M145-CCD error is to check the communication with the CCD device and ensure that the necessary signal, D720=1, is being transmitted. The issue could also be resolved by resetting
KM-ASSYM5-07
77
M146
M146-PLC timed out waiting for the CCD to reply with the result of taking the material and taking pictures (read D202=100 or D204=100)
Visual abnormality
The solution for the M146-PLC timed out waiting for the CCD to reply with the result of taking the material and taking pictures could be to check the communication settings between the PLC and CCD and ensure that they are
KM-ASSYM5-07
78
M147
M147-PLC timed out waiting for CCD to reply to the Mark point photo result (D206=100)
Visual abnormality
The solution for M147-PLC timeout error is to increase the timeout duration for the CCD in the PLC system. The timeout duration can be set in the PLC system's configuration, usually in the communication settings. Incre
KM-ASSYM5-07
79
M148
M148-PLC timed out while waiting for CCD to reply with product detection and photographing results (D207=100)
Visual abnormality
M148-PLC timed out while waiting for CCD to reply with product detection and photographing results (D207=100) is an error message indicating that the control system (PLC) is unable to
KM-ASSYM5-07
80
M149
M149-PLC timed out while waiting for CCD reply to the camera photo taking result (D230=100 or 101)
Visual abnormality
The error M149-PLC timed out while waiting for CCD reply to the camera photo taking result indicates that the PLC is waiting for a response from the CCD camera but is not receiving a reply. This error can be
KM-ASSYM5-07
81
M150
M150-PLC timed out while waiting for CCD to send the retrieval command (D208=1&2&3&4)
Visual abnormality
The solution to M150-PLC timed out while waiting for CCD to send the retrieval command could be to increase the timeout value in the PLC programming or to add a delay between the CCD command and the PLC
KM-ASSYM5-07
82
M151
M151-PLC timed out waiting for CCD to send the pickup coordinates of nozzle 1&2 (D210&D220)
Visual abnormality
The solution for the M151-PLC error is to increase the timeout value in the PLC program for the CCD camera to send the pickup coordinates of nozzles 1 and 2.
KM-ASSYM3-06
118
M7117
M7117-The number of required assemblies is more than the number of positioned cameras
Other exceptions
The M7117 error occurs when the number of required assemblies exceeds the number of positioned cameras in a camera-based manufacturing process. To resolve this issue, you can either increase the number of positioned cameras or optimize the assembly
KM-ASSYM3-06
119
M7118
M7118-CMC reply material number confirmation message timeout (10S)
Machine communication abnormality
The solution for the error M7118-CMC reply material number confirmation message timeout is to increase the timeout period to 10 seconds or set it to an appropriate value based on the system's requirements. Alternatively, checking the
KM-ASSYM3-06
120
M7119
M7119-CMC responded with incorrect material number confirmation information
Abnormal personnel operation
The solution for M7119-CMC responding with incorrect material number confirmation information is to review and double-check the material number being entered, ensure it follows the correct format, and try resetting the device or running material verification checks.
KM-ASSYM3-06
121
M7120
M7120-The function of confirming the material number of the host computer CMC has been blocked
Other exceptions
To resolve M7120 error, ensure that the host computer CMC is functioning properly and has the necessary permissions to access the material number confirmation function. You may also need to update the system or application software to the latest version. If the
KM-ASSYM3-06
67
M7066
M7066-X axis left limit is abnormal, far away from the origin end (X6), please check whether the slide table touches the limit
Electronic control abnormality
The M7066 error denotes that the left limit of the X axis is abnormal and far away from the origin end (X6). Checking whether the slide table touches the limit is recommended to solve this issue.
KM-ASSYM3-06
71
M7070
M7070-Y axis rear limit is abnormal, far away from the origin end (X10), please check whether the slide table touches the limit
Electronic control abnormality
The solution to the M7070-Y axis rear limit abnormal issue is to check if the slide table is touching the limit or if it has moved too far from the origin end (X10). If the slide table is touching
KM-ASSYM3-06
74
M7073
M7073-The limit on the Z axis is abnormal, close to the origin end (X13), please check whether the slide table touches the limit
Electronic control abnormality
The solution to M7073 error that states the limit on the Z axis is abnormal, close to the origin end (X13) is to check whether the slide table touches the limit. This can be accomplished by physically inspecting
KM-ASSYM3-06
84
M7083
M7083-PLC timed out waiting for the host computer to transmit the dispensing point position
Electronic control abnormality
The solution for the M7083-PLC timed out waiting for the host computer to transmit the dispensing point position error is to check the network communication between the SOPC unit and host computer, and ensure that the data transfer
KM-ASSYM3-06
90
M7089
M7089-PLC timed out waiting for the host computer to transmit the weighing result
Machine communication abnormality
To resolve the M7089-PLC timeout error, connect the instrument network connection to the device network connection of the host computer and ensure that the weighing result is being transmitted to a valid device. This should resolve the issue and
KM-ASSYM3-06
96
M7095
M7095-The host computer did not read the READ signal sent by TE, LINK fail
Kazam exception
If you encounter the M7095 error message ("The host computer did not read the READ signal sent by TE, LINK fail"), it often indicates a problem with the network adapter or the cable connection. First, make sure that the cable
KM-ASSYM3-06
101
M7100
M7100-When starting the machine, please clean the scale pan first and click the Cleared button before starting the machine.
Abnormal personnel operation
The solution to the M7100 error when starting the machine is to clean the scale pan and click the Cleared button before starting the machine. This will ensure that the scale is accurate and ready for use.
KM-ASSYM3-06
1
M7000
M7000-Thermal paste is about to run out, please prepare thermal paste
Abnormal personnel operation
This error message usually appears on a printer to notify the user that the thermal paste is running out and the user needs to replace it before the printer will continue to function properly. The printer uses thermal paste to help maintain a consistent temperature of the printer head
KM-ASSYM3-06
2
M7001
M7001-Start detecting that there is material in the work area, please select the work area status
Abnormal personnel operation
The solution for the error "M7001-Start detecting that there is material in the work area, please select the work area status?" is to ensure that the appropriate work area is selected before starting the processing by either re-routing
KM-ASSYM3-06
17
M7016
M7016-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X22)
Abnormal personnel operation
The solution for the error described as M7016-EMO&&DOOR is on, is to check the safety door and emergency stop switch (X22). If either of these components is faulty, it can cause the error